Laserfiche WebLink
NDE: ULTRASONIC TESTING INSPECTION REPORT <br />Report Number: M7241069.0003 <br />Service Date: 02/23/24 <br />Report Date: 02/24/24 <br />Client <br />Pietromonaco Jackson Properties LLC <br />Attn: Kyle Kauzlarich <br />7525 SE 24th St Ste 300 <br />Mercer Island, WA 98040 <br />General Information <br />■ rerracon <br />20225 Cedar Valley Rd Ste 110 <br />Lynnwood, WA 98036-6365 <br />425-742-9360 <br />Project <br />Everett Mall Office -Exterior Upgrades <br />1000 SE Everett Mall Way <br />Everett, WA <br />Project Number: M7241069 <br />Custom Steel requested Terracon be on site for ultrasonic testing. Structural steel is being constructed by Custom Steel. The results of <br />observation(s) for today were reported to Custom Steel. <br />The construction documents referenced for this observation include: Shop Dwg's 12-15-23. <br />Ultrasonic Testing Information <br />Instrument <br />UT Equipment-65776 <br />Amplitude <br />Calibration <br />Expiration Date <br />2024-02-29 <br />Surface Surface Transducer(s) Used <br />Cleanliness Preparation <br />Clean As Welded 701, 0.625-inch, 2.25 mHz <br />Terracon Procedure No. <br />TC-AW S-UT4 <br />Calibration Block <br />IIW 2 <br />Acceptance Criteria <br />D1.1-15 Table 6.1/6.2 <br />Couplant Index Point <br />Verification <br />Glycerin Yes <br />Compliance Statement <br />Based on our observations, structural steel construction activities at the above -referenced locations appeared to be completed in general <br />accordance with the project plans and specifications. <br />Services: Special Inspections / Materials Testing <br />Terracon Rep.: Nicholas Leede <br />Reported To: Custom Steel <br />Contractor: Custom Steel <br />Report Distribution: <br />(1) Pietromonaco Jackson Properties (1) Mayes Testing Engineers, Inc, Gale <br />LLC, Kyle Kauzlarich Noyes <br />(1) Mayes Testing Engineers, Inc, Mike (1) Skyline Construction Inc, Jakob Reviewed By: <br />Ma f.,.. <br />(1) Skyline Construction Inc, Josh <br />Eaton Michael Mattox <br />Group Manager <br />The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above <br />and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at <br />the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. <br />DM029, 04-29-22 Rev.2 Page 1 of 1 <br />