FABRICATION SHOP OBSERVATION REPORT <br />Report Number: M7241069.0001 <br />Service Date: 02/21/24 <br />Report Date: 02/21/24 <br />Client <br />Pietromonaco Jackson Properties LLC <br />Attn: Kyle Kauzlarich <br />7525 SE 24th St Ste 300 <br />Mercer Island, WA 98040 <br />Permit # B2311-123 <br />General Information <br />■ rerracon <br />20225 Cedar Valley Rd Ste 110 <br />Lynnwood, WA 98036-6365 <br />425-742-9360 <br />Project <br />Everett Mall Office -Exterior Upgrades <br />1000 SE Everett Mall Way <br />Everett, WA <br />Project Number: M7241069 <br />Custom Steel requested Terracon be at the Custom Steel shop located at 3530 Rainier Avenue South Seattle for the following services: steel <br />fabrication. The results of observation(s) for today were reported to Anh Phan. <br />The construction documents referenced for this observation include: C1 & C2 dated 12-15-23. <br />Fabrication Observation <br />Terracon provided shop fabrication observation due to jurisdictional requirements. <br />Terracon performed a review of the welder qualifications and welding procedures provided. No welding observation was performed today. See <br />below for a summary of the reviewed items. <br />Welder Qualification <br />Welder Name Welder ID <br />Anh Phan W02851 D <br />Additional Comments <br />Fit up of column plates acceptable. <br />Process/Procedure <br />Process Filler Metal Shielding/Flux <br />FCAW E71T-1 N/A <br />WPS No. <br />Cp-1 <br />Compliance Statement <br />Based on our observations, structural steel construction activities at the above -referenced locations appeared to be completed in general accordance <br />with the project plans and specifications. <br />Services: Special Inspections / Materials Testing <br />Terracon Rep.: Mark Vassallo <br />Reported To: Anh Phan <br />Contractor: <br />Report Distribution: <br />(1) Pietromonaco Jackson Properties <br />(1) Mayes Testing Engineers, Inc, Gale <br />LLC, Kyle Kauzlarich <br />Noyes <br />(1) Mayes Testing Engineers, Inc, Mike <br />Ma f. <br />(1) Skyline Construction Inc, Jakob <br />u—H.r- <br />Reviewed By: D <br />(1) Skyline Construction Inc, Josh <br />Michael Mattox <br />Eaton <br />Group Manager <br />The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above <br />and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at <br />the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. <br />DM006, 04-29-22 Rev.2 Page 1 of 1 <br />