Laserfiche WebLink
w.sn�n E EVERETT �', <br /> EVERTT d <br /> Everett Fire Dept. Permit Review <br /> Global Project Values: Status:Approved <br /> Honeywell Project Name:ITERA STAFFING EMOP II Standby Hours: 24 Reviewed By: KBrown <br /> ®SILENT Project ID:KL4667 Alarm Mins:� 09/06/2023 9:20:23 <br /> KNIGHT Prepared By:Western States Fire Protection Derating Factor: 1.2 AM <br /> 6820 Battery Calculator(SK) Date:8/31/2023 Voltage Drop Warning <br /> Version 18.05.29 Threshold%: 15 <br /> Panel ID:16820 Model:6820 Add.Fire Alarm Control Max NAC Current: 3.0 Amps <br /> Location:11 st FL Storage Room Volts: 24 VDC Max Panel Current: 6.0 Amps <br /> Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ <br /> Ckt.# Circuit Name Qty StandbyAlarm &Type 1000 Ft. One-Way Ohms EOL Drop <br /> 6820 6820 CTRL Panel 1 0.275 1 0.440 <br /> SK Photo,Photo-T,Photo-R 284 0.085 0.085 <br /> SK Heat,Heat-HT 9 0.003 0.003 <br /> SK Heat ROR 0.000 0.000 <br /> SK Beam,Beam-T 0.000 0.000 <br /> SK Duct 0.000 0.000 <br /> SK jAcclimate 0.000 0.000 <br /> SK Fire-CO 0.000 0.000 <br /> SK-PHOTO-W Photo W 0 0.000 0.000 <br /> SK-PHOTO-R-W Photo-R-W 0.000 0.000 <br /> SK-PHOTO-T-W Photo-T-W 0.000 0.000 <br /> SK-HEAT-W Heat-W 0 0.000 0.000 <br /> SK-HEAT-ROR- Heat-ROR-W 0.000 0.000 <br /> SK-HEAT-HT-W Heat-HT-W 0.000 0.000 <br /> SK Control 3 0.001 0.001 <br /> SK Control-6 0.000 0.000 <br /> SK Monitor,Minimon 1 0.000 0.000 <br /> SK Monitor-2 0.000 0.000 <br /> SK Monitor-10 0.000 0.000 <br /> SK Pull-SA,Pull-DA 12 0.005 0.005 <br /> SK Relay 3 0.001 0.001 <br /> SK Relay-6 0.000 0.000 <br /> SK Zone 0.000 0.000 <br /> SK Zone-6 0.000 0.000 <br /> SK Relay-Mon-2 1 0.000 0.000 <br /> SK Isolator Module 0.000 0.000 <br /> B224BI Isolator Base 0.000 0.000 <br /> B200SR Sounder Base 0.000 0.000 <br /> B200S Sounder Base 0.000 0.000 <br /> B200SR-LF Low Freq Sounder Base 0.000 0.000 <br /> B200S-LF Low Freq Sounder Base 0.000 0.000 <br /> 13224RB Relay Base 0.000 0.000 <br /> RTS151 Magnetic Remote Test 0.000 0.000 <br /> RTS151KEY Key Activated Test 1 0.000 0.000 <br /> RA100Z Remote LED 0.000 0.000 <br /> 6815 SLC Loop Expander 2 0.110 0.110 <br /> 5860 LCD Remote Annunc 1 0.020 0.056 <br /> 5824 Serial/Parallel Module 0 0.000 0.000 <br /> 5496 Power Expander 0.000 0.000 <br /> 5895XL Power Expander 0.000 0.000 <br /> 5865-4 LED Annunciator 4G 0.000 0.000 <br /> 5865-3 LED Annunciator(3G) 0.000 0.000 <br /> 5880 LED Driver Module 0 0.000 0.000 <br /> 5883 Relay Module 0 0.000 0.000 <br /> SK-NIC Network Input Card 0 0.000 0.000 <br /> SK-FML Muilti-Mode Fiber Card 0 0.000 0.000 <br /> SK-FSL Single-Mode Fiber Card 0 0.000 0.000 <br /> PGM-1/0#1 Notification App1 Circuit 0.000 0.534 #14 Solid 2.52 123 0.62 20.07 1.62% <br /> PGM-1/0#2 Notification Appl Circuit 0.000 0.984 #14 Solid 2.52 153 0.77 19.64 3.72% <br /> PGM-1/0#3 Notification App1 Circuit 0.000 0.923 #14 Solid 2.52 311 1.57 18.95 7.09% <br /> PGM-1/0#4 Notification Appl Circuit 0.000 0.000 #14 Solid 2.5 0.00 20.40 0.00% <br /> PGM-1/0#5 Notification App1 Circuit 0.000 0.000 #14 Solid 2.52 0.00 20.40 0.00% <br /> PGM-1/0#6 Notification Appl Circuit 0.000 0.000 1#14 Solid 2.52 0.00 20.40 0.00% <br /> Total Standby Current(Amps) 0.500 0.004 Total Alarm Current(Amps) <br /> Standby Time In Hours 24 0.083 Alarm Time In Minutes/60 (5 Mins) <br /> Total Standby AH Required 11.9921 0.000 Total Alarm AH Required <br /> Total Combined AH Required 11.99 Command Shortcuts <br /> Multiply By The Derating Factor 1.20 <br /> Minimum Battery AmpHours Required 14.39 Configure Circuits Print Page J <br />