My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1000 SE EVERETT MALL WAY 301, 306 TERRA STAFFING 2025-07-31
>
Address Records
>
SE EVERETT MALL WAY
>
1000
>
TERRA STAFFING
>
1000 SE EVERETT MALL WAY 301, 306 TERRA STAFFING 2025-07-31
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2025 12:02:41 PM
Creation date
4/24/2025 11:39:32 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1000
Unit
301, 306
Tenant Name
TERRA STAFFING
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
103
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LL <br /> CO <br /> v LL 0 <br /> T RRA TAFFING MOP 11 <br /> C_ <br /> C_ U <br /> FIRE ALARM SYSTEM OPERATIONAL MATRIX V <br /> ALARM TROUBLE SUPERVISORY MISCELLANEOUS M N <br /> p1�C' GENERAL NOTES N <br /> w <br /> V 1� QO 1.FACTORY RECOMMENDED MINIMUM WIRING SIZES,TYPE AND 7.PARALLEL BRANCHING OF WIRE TO ALL NOTIFICATION APPLIANCE Q <br /> CONSTRUCTION AS NOTED ON THE DRAWINGS MUST BE STRICTLY CIRCUITS SHALL NOT BE PERMITTED. o <br /> ¢ FOLLOWED.ANYONE WILLING TO MAKE CHANGES WILL DO SO AT <br /> THEIR OWN RISM 8.PARALLEL BRANCHING OF WIRE TO ADDRESSABLE INITIATING DEVICE <br /> G� 2.THE CIRCUIT ROUTING AND WIRING COUNTS ON THE FLOOR PLAN CIRCUITS IS PERMISSIBLE. � <br /> DRAWINGS ARE SHOWN DIAGRAMMATIC BASED ON CONTINUOUS AND 9.PER NFPA 72,SECTION 29.8.3.4(7):SMOKE ALARMS AND SMOKE p w <br /> SHORTEST POSSIBLE ROUTING FROM THE CONTROL PANEL AND DETECTORS SHALL NOT BE INSTALLED WITHIN A 361N.(91 OMM) ( �I <br /> BETWEEN CONNECTED FIELD DEVICES WITH NO PHYSICAL HORIZONTAL PATH FROM THE SUPPLY REGISTERS OF A FORCED AIR > K <br /> w <br /> ,�'OC Q• Q• Q• .�. �. y y y ,�,�,� .�.�.� OBSTRUCTIONS.THE WIRING OR CIRCUIT COUNTS(IF SHOWN)ARE HEATING OR COOLING SYSTEM AND SHALL BE INSTALLED OUTSIDE OF <br /> PROVIDED AS A CONVENIENCE ONLY AND AS MEANS TO HASTEN THE DIRECT AIRFLOW FROM THOSE REGISTERS. w <br /> INSTALLATION OR TO DETERMINE WIRING ROUTES. <br /> CAUSE 5 REMARKS 10.SMOKE ALARMS AND CO-DETECTION WILL BE INSTALLED BY N <br /> SMOKE HEAT DETECTORS • • • • • 3.WIRE SHOWN IN THIS DRAWING SET IS PERMITTED IN RACEWAYS ELECTRICAL CONTRACTOR. <br /> MANUAL PULL STATION • • • • • LEADING TO FIRE PROTECTION EQUIPMENT.OTHER WIRE SHALL NOT BE Oz o <br /> SYSTEM RESET • PERMITTED. 11.THE AUDIBLE ALARM NOTIFICATION APPLIANCES SHALL PROVIDE A <br /> SIGNAL SILENCE • • SOUND PRESSURE LEVEL OF 15 DECIBELS(dBA)ABOVE THE AVERAGE <br /> AC POWER FAILURE • • • 4.PER NFPA 72,SECTION 17.7.1.11.3:WHERE DETECTION IS NOT AMBIENT SOUND LEVEL OR 5 dBA ABOVE THE MAXIMUM SOUND LEVEL <br /> REQUIRED DURING CONSTRUCTION,DETECTORS SHALL NOT BE HAVING A DURATION OF NOT LESS THAN 60 SECONDS,WHICHEVER IS <br /> FIRE ALARM TROUBLE(OPEN, INSTALLED UNTIL AFTER ALL OTHER CONSTRUCTION TRADES HAVE GREATER,IN EVERY OCCUPIABLE SPACE WITHIN THE BUILDING.IN zo <br /> SHORTS,OR GROUNDS)ON • • • COMPLETED CLEANUP. COMPLIANCE WITH CURRENT IFC AND NFPA 72 CODES. r N <br /> INITIATION OR SIGNALING CIRCUITS x <br /> TAMPER SWITCHES • • • 5.FIRE ALARM SYSTEM INSTALLATION SHALL CONFORM WITH THE <br /> WATERFLOW SWITCH 010101 10101 LATEST U.L.,N.E.C.,N.F.P.A.,W.A.C.,AND OTHER STANDARDS AS O <br /> APPLICABLE TO THE CITY STANDARDS. w w <br /> w <br /> 6.WHEN NECESSARY,DUE TO CHANGING DESIGN REQUIREMENTS, � <br /> FACTORY AVAILABILITY,ETC.WE RESERVE THE RIGHT TO SUBSTITUTE z_ <br /> EQUIPMENT HEREIN MENTIONED OR SPECIFIED,WITH EQUIPMENT OF - <br /> EQUAL OR BETTER QUALITY,FUNCTION AND DESIGN. 3 <br /> SCOPE OF WORK: <br /> _ o <br /> -ADD/RELOCATE A/V NOTIFICATION & INITIATING AS NEEDED <br /> EX FIRE ALARM DEVICE LEGEND <br /> 30 SYMBOL QTY DESCRIPTION MODEL NUMBER MANUFACTURER BACKBOX MOUNTING HEIGHT <br /> EX <br /> Wp AC EX FIRE ALARM CONTROL PANEL 6820 SILENT KNIGHT MOUNT ON WALL TOP 72"AFF <br /> 110 CP EX FIRE CONTROL POWER SUPPLY HPFF-S HONEYWELL MOUNT ON WALL TOP 66"AFF <br /> E% <br /> ANN EX ANNUNCIATOR 5860R SILENT KNIGHT MOUNT ON WALL TOP 66"AFF <br /> 30 <br /> Ex EXP EX SLC EXPANDER 6815 SILENT KNIGHT MOUNT INSIDE FACP _ <br /> 30 1 HORN STROBE-CEILING MOUNT PC2RL SYSTEM SENSOR 4S BOX CEILING Z <br /> Q <br /> 2 STROBE-CEILING MOUNT SCRL SYSTEM SENSOR 4S BOX CEILING } d <br /> T <br /> Y*�' 30 nn EX OUTDOOR HORN/STROBE P2RK SYSTEM SENSOR 4S BOX VERIFY IN FIELD Q cc <br /> EX o� EX <br /> C < ® EX PULL STATION SK-PULL SILENT KNIGHT 4S BOX 42"-48"AFF LLI <br /> 15 JEX <br /> 30 d J Ln <br /> Ex Ex Ex ® EX HEAT DETECTOR SK-HEAT SILENT KNIGHT 4S BOX CEILING O Q cc <br /> 30 30 � 2 PHOTO SMOKE SK-PHOTO SILENT KNIGHT 4S BOX CEILING 1J 1 00 <br /> 00 (n <br /> E 04 <br /> x Ex © EX CONTROL MODULE SK-CONTROL SILENT KNIGHT 4S BOX VERIFY IN FIELD (� Q <br /> Z ~ � J <br /> ti 95 ex Ex 30 Ex ® EX RELAY MODULE SK-RELAY SILENT KNIGHT 4S BOX VERIFY IN FIELD LL � Q d <br /> C <br /> C��� ❑M EX MONITOR MODULE SK-MINIMON SILENT KNIGHT 4S BOX VERIFY IN FIELD Q j C <br /> 30 30 30 < <br /> Ex ExEx Ex <br /> 3RD FLOOR _ _ W H J <br /> 4 30 30 30 NIW Q <br /> Ex EX ExEX 909 Business Center O -1 o WW <br /> Ir <br /> e x1230 30 300 �Lese� H W LL <br /> EX E% E% EX EX EX EXEX EX 030 30 !�$® - O <br /> Basil Authentic <br /> EX E% EX Vietnamese Cuisine <br /> Ex EX EX E% E% EX EX _- 0 Hantle Atm <br /> iz z z a 30 30 30 30 <br /> X E% E% EX E% <br /> EX EX E% EX EX <br /> w ao H <br /> t ? P ? 30 EX 95 EX 30 EX 30 Ex _- ' B19F001 Java • A�A11 O z i <br /> EX EX EX E% E% E% E% VI <br /> z Ex x7 30 30 30 30 Be JULES MAYER,SET r 1 <br /> 2 P ? ? ? EX EX EX Applebees Grill+Bar Ele' NICET N130993 U °- i 8 <br /> EX EX EX EX <br /> FIRE ALARM SYSTEMS.LEVEL IV <br /> w x� <br /> H EX H E% 30 EX 30 EX 30 Ex 95 E% ' S <br /> Everett Mall Office Park Shar <br /> 30 EX 75 30 Ex 30 Ex O 12 Bob) <br /> V1 H"1 o a <br /> A EX A 0 ; a <br /> A A A A AA'' <br /> W e S z <br /> FRCP FCPSN2 00 <br /> SILENT KNIGHT HONEri4ELL <br /> 6820 HPFF-8 <br /> eiRE AHEM FIRE� VICINITY MAP <br /> co NEOL POPWEER NI THE CIRCUIT ROUTING AND WIRING COUNTS ON THE <br /> D A PLY CTKT #I BADDD ONACONRTI UOUS AND SHORTESARE SHOWN T POSSIBLE IC <br /> NAC CIRCUIT) ROUTING FROM THE DEVICES <br /> PANEL AND BETWEEN <br /> 120VAC B C CONNECTED FIELD DEVICES WITH ND PHYSICAL <br /> 20 AMP DEDICATED CIRCUIT NAC# ❑BSTRUCTIONS. THE WIRING OR CIRCUIT COUNTS <br /> (IF SHOWN) ARE PROVIDED AS A CONVENIENCE <br /> ONLY AND AS MEANS TO HASTEN INSTALLATION <br /> FIRE ALARM RISER OR <br /> WIRININ DETERMINE WIRING ROUTS. ALL FIRE ALARM G CAN BE RAN IN SAME CONDUIT. <br />
The URL can be used to link to this page
Your browser does not support the video tag.