Laserfiche WebLink
'-31/z" <br />---- --------------------------- <br />L <br />J I <br />C I <br />CU <br />. O <br />m Lr) <br />I 1 l l <br />l l <br />2"JEWELITE TRIMCAP - 72" LETTERS <br />PMS 312C BLUE DIGITAL OVERLAY <br />BY MIRATEC <br />00 <br />--- ------ ----- <br />I ----- ----- <br />OPLEX FACE CHANNEL LETTERS 109.2 Sq Ft <br />(1 ) SET REQUIRED Scale: 1/4' = 11-0" <br />Calculations for Sign Area - measuring the smallest rectangle enclosing each letter and totaling the square footage thereof. <br />a - 49.796 x 46.85 = 16.2 sq. ft. <br />t 22.076 x 61.42 = 9.41 sq. ft. <br />h - 49.947 x 71.970 = 24.96 sq. ft. <br />. - 48.197 x 51.797 = 17.33 sq. ft. <br />M - 47.043 x 75.904 = 24.79 sq. ft. <br />e - 48.035 x 48.971 = 16.33 sq. ft. <br />square foot total = 109.2 sq. ft. <br />INSTALLATION REQUIREMENTS for all signs unless specified otherwise on individual sign specifications <br />Variation from this criteria without written approval from Accent Graphics is strictly forbidden. <br />' All freestanding signs are to be engineered for local conditions by a licensed and registered engineer. <br />MOUNTING SURFACE <br />v <br />SQUARE <br />SHEET <br />CONCRETE <br />DRYVIT/ <br />STUCCO <br />FOOTAGE <br />WOOD <br />METAL <br />BRICK <br />CONCRETE <br />BLOCK <br />EIFIS <br />over wire mesh u <br />UNDER <br />18'THRU BOLTS <br />w/ 2' angle iron backer <br />N8'THRU BOLTS <br />w/ 2' angle Iron backer <br />3/8- LEAD ANCHORS <br />3,8-LEAD ANCHORS <br />IS' TOGGLE <br />38'THRU BOLTS <br />.12 angle iron backer <br />3/8'THRU BOLTS ,Np, <br />w/ 2' angle Iron backer ' <br />1030.FT. <br />A-mon.ma(4)3/8' <br />Aminimumof(4)3/8' <br />Aminimumof(413/8' <br />Aminlmumof(4)318' <br />Aminimumof(4)318' <br />Aminimumof(4)3/8' <br />0 <br />Amon mof(4)318' W <br />bolts are required. <br />Wits are required. <br />bolls are required. <br />both are required <br />bolts are required. <br />bolts are required <br />bolts are required. a, <br />JJ 10 SQ. FT. <br />3,8" THRU BOLTS <br />3/8' THRU BOLTS <br />M"LEAD ANCHORS <br />3'8' LEAD ANCHORS <br />18' TOGGLE <br />318' THRU BOLTS <br />318' THRU BOLTS <br />wl 2' angle iron backer <br />w/ 2' angle iron backer <br />.12 angle iron backer <br />w/ 2' angle into backer <br />to <br />n TO <br />uJ 50 SO. FT. <br />Aminimum of(4)3/8' <br />Aminimum o1(4)&18' <br />Aminm rn of(4)3I8' <br />Aminimum of(4) 3/8' <br />Aminimum of(4)3/8' <br />Aminimumof (4)Y8' <br />Aminimumof(413:8- W <br />polls are required. <br />halts are regwred. <br />bah are required <br />bah are required <br />bolts are required, <br />bola are required <br />bolts are requimd. <br />SOSQ.FT. <br />3'8'THRUBOLTS <br />318' THRU BOLTS <br />1/2-LEAD ANCHORS <br />1i2-LEADANCHORS <br />3/8'THRUBOLTS <br />3/8-THRU BOLTS <br />3/8'THRUBOLTS <br />'r1 <br />J_ TO <br />wl 3' angle iron backer <br />wl Tangle iron backer <br />wl t' angle iron backer <br />wl 3' angle loon backer <br />w/ Tangle iron backer <br />n 1OO SQ. FT. <br />A minimum of(10118- <br />A minimum of( tU) 3. 8- <br />A minimum of(10) 112' <br />A minimum of(10) 1/2' <br />Aminimum of(10) 318' <br />A minimum of(10) M- <br />Amnimm iuof(10)T8- — <br />Wits are required. <br />Its are requinetl. <br />bolts arerequire0 <br />Dolts arerequired <br />Dolts are required <br />bolts are requirect. <br />polls are requiretl. <br />O <br />100 SQ. FT. <br />12'THRU BOLTS <br />1/2'THRU BOLTS <br />7l2•WEDGEANCHOR <br />12'WEDGEANCHOR <br />1/2-THRU BOLTS <br />^ <br />TO <br />wt 3' angle iron backer <br />w/ 3' angle iron backer <br />w/ 3' angle iron packer <br />REQUIRES SPECIAL <br />REQUIRES SPECIAL <br />200 SQ. FT. <br />Aminimum of(1) 1IY <br />bolt oar each 15 sq n <br />Aminimum of(1) 1IY <br />bolt Van each 15 sq n <br />A minimum of Irr <br />bo8 per each 15 sq n <br />A minimum of 12' <br />bolt per each 15 sq n <br />Aminimum a(1)1,2' <br />boll per each 15 sq ft <br />ENGINEERING <br />ENGINEERING <br />is required. <br />s required. <br />is required. <br />is required. <br />is requited. <br />X <br />1/2' THRU BOLTS W <br />1/2' THRU BOLTS wl <br />u <br />OVER <br />REQUIRES SPECIAL <br />REQUIRES SPECIAL <br />at sas13 ayle iron tacker <br />at least f-angle nen Oxke' <br />SPECIAL <br />REQUIRES SPECIAL <br />REQUIRES SPECIAL <br />200 SQ. FT. <br />ENGINEERING <br />ENGINEERING <br />poltlpeteacb l(51sg1n2 <br />urnREQUIRES <br />boltPareachli51sgln2 <br />ENGINEERING <br />ENGINEERING <br />ENGINEERING ?, <br />NOTE: <br />ACCESS REQUIRED FOR <br />ELECTRICAL & INSTALLATION <br />ARIA <br />5„ fllll:�j <br />[21.040 0.063 ALUMINUM <br />BACKS & RETURNS <br />COLOR -PMS 424C DARK GRAY SEMI GLOSS <br />LOCKABLE DISCONNECT <br />2" JEWELITE TRIMCAP <br />IN COMPLIANCE WITH <br />NEC 600.6(2) AND 110.25 <br />COLOR -PMS 424C DARK GRAY SEMI GLOSS <br />/ <br />TRANSLUCENT PLEX FACE <br />I <br />REMOTE POWER SUPPLY UNIT. <br />THICKNESS - 0 3/16U 1/8" <br />120 VAC PRIMARY <br />COLOR - LETTERS = WHITE <br />1 11 <br />24volt DC SECONDARY. <br />LOGO = WHITE + PMS 312C BLUE <br />OVERLAY BY MIRATEC <br />NUMBER REO'D. _ <br />LED ILLUMINATIO <br />COLOR -WHITE <br />e.. M Kaboratories <br />NON -CORROSIVE El YES <br />FASTENERS AS REQ'D. <br />❑ NO <br />CLN <br />1/4" WEEP HOLES []YES []NO <br />DYES ❑NO <br />SECTION DETAIL - PLEX FACE CHANNEL LETTERS w/ LED ILLUMINATION <br />Scale: NTS <br />DATE <br />I REVISIONS <br />NAME AUTHORIZATION <br />This drawing is the exclusive property of Accent Graphics, Inc. <br />and is the result of the original work of its employees. The plans <br />provided to your company for the sole purpose of considering <br />the purchase of a sign manufactured by Accent Graphics, Inc. <br />based on these plans OR the purchase of the plans and design <br />concepts contained therein for manufacture elsewhere. Distribu- <br />SHERWIN WILLIAMS <br />CLIENT STORE # <br />INSTALLATION ADDRESS <br />1302 S E Everett Mall Way I Everett, WA 98208 <br />accent graphics <br />COMPLETE SIGN SERVICE & FABRICATION <br />11-15-2021 <br />add & revise pylons and directionals from property survey 3 <br />KID <br />11-17-2021 <br />REVISE SIGN C AS AN 8 FT SCONCE % <br />KIDare <br />CLIENT DATE <br />11-18-2021 <br />REVISE SIGN Ato 6FT TALL, BOX IN SQUARE FT CALC. PER LETTER '/. <br />KID <br />12-09-2021 <br />REVISE DIRECTIONAL VINYL LETTERING TO LOWERCASE 1 <br />KID ACCOUNT EXECUTIVE DATE <br />KID <br />tion or exhibition of the plans to anyone outside of your company <br />or the use of the plans by others to manufacture or design a <br />similarsign asdisplayed inthe plans isexpressly forbidden. In <br />DESIGNER KD ACCOUNT EXECUTIVE D M <br />10-28-2021 1 18 211125-07 <br />DATE SHEET OF DESIGN# <br />523 E. ROCK ISLAND TOLL FREE (800) 810-3044 <br />GRAND PRAIRIE, TX 75050 METRO (972)399-0333 <br />01-17-2022 <br />REVISE DIRECTIONAL "N" TO OVERLAY BOTH SIDES 1 <br />LANDLORD DATE <br />ALL CHANGES MUST BE INITIALED BY <br />the event that such exhibition occurs, Accent Graphics will expect <br />payment of a minimum $2000 design fee in recompense for the <br />Gerber FILE = <br />FAX 972 986-4456 <br />EMAIL ( ) <br />CLIENT AND ACCOUNT EXECUTIVE O <br />FINAL APPROVED PRINT. <br />time and effort entailed to produce the plans. <br />COrel FILE = <br />WEBSITE www.accentgraphicsinc.com FAX (800) 810-3045 <br />Regulated by the Texas Department of Licensing and Regulation P. O. Box 12157, Austin, TX 78711 Tel: 512.463.6599 Toll Free (in TX): 800.803.9202 Online: http://www.license.state.tx.us/complaints State of Texas Contractor #18050 �1 <br />/ <br />