Laserfiche WebLink
DF-52417:D • B-90 <br />ANN-80 <br />SO -Character Serial LCD Annunciator <br />General <br />The ANN-80 annunciator is a compact, backlit, 80-character LCD <br />fire annunciator that mimics the Fire Alarm Control Panel (FACP) <br />display. It provides system status indicators for AC Power, Alarm, <br />Trouble, Supervisory, and Alarm Silenced conditions. The ANN-80 <br />and the FACP communicate over a two -wire serial interface employ- <br />ing the ANN-Bus communication format. Connected devices are <br />powered, via two additional wires, by either the host FACP or a <br />remote UL-listed, filtered power supply. The ANN-80 is red; for <br />white, orderANN-80-W. <br />The ANN-80 displays English -language text of system point informa- <br />tion including device type, zone, independent point alarm, trouble or <br />supervisory status, as well as any custom alpha labels programmed <br />into the control panel. It includes control switches for remote control <br />of critical system functions. (A keyswitch prevents unauthorized <br />operation of the control switches.) <br />Up to eight ANN-80s may be connected to the ANN-Bus of each <br />FACP. No programming is required, which saves time during system <br />commissioning. <br />Features <br />• Listed to UL Standard 864, 9th Edition <br />• Backlit 80-character LCD display (20 characters x 4 lines) <br />• Mimics all display information from the host panel <br />• Control switches for System Acknowledge, Signal Silence, Drill, <br />and Reset <br />• Control switches can be independently enabled or disabled at the <br />FACP <br />• Keyswitch enables/disables control switches and mechanically <br />locks annunciator enclosure <br />• Keyswitch can be enabled or disabled at the FACP <br />• Enclosure supervised for tamper <br />• System status LEDs for AC Power, Alarm, Trouble, Supervisory, <br />and Alarm Silence <br />• Local sounder can be enabled or disabled at the FACP <br />• ANN-80 connects to the ANN-Bus terminal on the FACP and <br />requires minimal panel programming <br />• Displays device type identifiers, individual point alarm, trouble, <br />supervisory, zone, and custom alpha labels <br />• Time -and date display field <br />• Surface mount directly to wall or to single, double, or 4" square <br />electrical box <br />• Semi -flush mount to single, double, or 4" square electrical box. <br />Use ANN-SB80KIT for angled view mounting <br />• Can be remotely located up to 6,000 feet (1,800 m) from the <br />panel <br />• Backlight turns off during AC loss to conserve battery power but <br />will turn back on if an alarm condition occurs <br />• May be powered by 24 VDC from the host FACP or by remote <br />power supply (requires 24 VDC) <br />• Up to eight ANN-80s can be connected on the ANN-Bus <br />Controls and Indicators <br />• AC Power <br />• Alarm <br />• Trouble <br />(2) Flre•ureaLarms <br />by Honeywell <br />Supervisory <br />Alarm Silenced <br />Specifications <br />• Operating voltage range: 18 VDC to 28 VDC <br />• Current consumption @ 24 VDC nominal (filtered and non- <br />resettable): 40 mA maximum <br />• Ambient temperature: 32°F to 120°F (0°C to 49°C) <br />• Relative humidity: 93% ± 2% RH (non -condensing) at 32°C ± <br />2°C (90°F ± 3°F) <br />• 5.375" (13.65 cm.) high x 6.875" (17.46 cm.) wide x 1.375" (3.49 <br />cm.) deep <br />• For use indoors in a dry location <br />• All connections are power -limited and supervised <br />The ANN-Bus <br />POWERING THE DEVICES ON THE ANN-BUS FROM AUXIL- <br />IARY POWER SUPPLY <br />The ANN-Bus can be powered by an auxiliary power supply when <br />the maximum number of ANN-Bus devices exceeds the ANN-Bus <br />power requirements. See the FACP manual for more information. <br />ANN-BUS DEVICE ADDRESSING <br />Each ANN-Bus device requires a unique address (ID Number) in <br />order to communicate with the FACP. A maximum of 8 devices can <br />be connected to the FACP ANN-Bus communication circuit. See the <br />FACP manual for more information. <br />WIRE REQUIREMENTS: COMMUNICATIONS CIRCUIT <br />The ANN-80 connects to the FACP ANN-Bus communications cir- <br />cuit. To determine the type of wire and the maximum wiring distance <br />that can be used with FACP ANN-Bus accessory modules, it is nec- <br />essary to calculate the total worst case current draw for all modules <br />on a single 4-conductor bus. The total worst case current draw is <br />calculated by adding the individual worst case currents for each <br />module. <br />NOTE. For total worst case current draw on a single ANN-Bus refer to <br />appropriate FACP manual. <br />DF-52417:D • 3/15/2018 — Page 1 of 2 <br />