Laserfiche WebLink
INSTALLATION AND MAINTENANCE INSTRUCTIONS <br />MMF-301 Monitor Module <br />Fire-LIMALarms71 <br />by Honeywell CD <br />One FireLite Place <br />Northford, CT 06472 <br />Phone: 203.484.7161 <br />SPECIFICATIONS <br />Nominal Operating Voltage: <br />15-32 VDC <br />Average Operating Current: <br />375 pA (group poll); 350 µA (direct poll); 600 pA Maximum (Communicating, IDC Shorted) <br />EOL resistance: <br />47K ohms <br />Maximum IDC Resistance: <br />1,500 Ohms <br />Maximum IDC Voltage: <br />11 Volts <br />Maximum IDC Current: <br />450 µA <br />Temperature Range: <br />32°F to 120` F (0°C to 49° C) <br />Humidity: <br />10% to 93% Non -condensing <br />Dimensions: <br />1.3" H x 2.75" W x 0.65" D <br />Wire length: <br />6" minimum <br />BEFORE INSTALLING <br />This information is included as a quick reference installation guide. Refer to <br />the control panel installation manual for detailed system information. If the <br />modules will be installed in an existing operational system, inform the opera- <br />tor and local authority that the system will be temporarily out of service. Dis- <br />connect power to the control panel before installing the modules. <br />NOTICE: This manual should be left with the owner/user of this equipment. <br />GENERAL DESCRIPTION <br />The MMF-301 monitor module can be installed in a single gang junction box <br />directly behind the monitored unit. Its small size and light weight allow it to <br />be installed without rigid mounting (see Figure 1). The MMF-301 is intended <br />for use in intelligent, two -wire systems where the individual address of each <br />module is selected using rotary switches. It provides a two -wire initiating cir- <br />cuit for normally open contact fire alarm and security devices. This module <br />can be used to replace an M301 module in existing systems. <br />COMPATIBILITY REQUIREMENTS <br />To ensure proper operation, this module should only be connected to listed <br />compatible system control panels only. <br />FIGURE 1: <br />MOUNTING AND WIRING <br />NOTE: This module is intended to be wired and mounted without rigid con- <br />nections inside a standard electrical box. All wiring must conform to appli- <br />cable local codes, ordinances, and regulations. <br />1. Connect the red (+ ) and black (-) wires to the positive and negative loop <br />power leads of the Signaling Line Circuit (SLC). <br />2. Connect the violet (+) and yellow (-) wires to a two -wire, normally open <br />initiating loop. <br />3. Install the specified EOL resistor value to terminate the initiating loop. <br />4. Set the address on the module per job drawings. <br />5. Install the module in the desired mounting location. <br />FIGURE 2. TYPICAL 2-WIRE STYLE B INITIATING DEVICE CIRCUIT <br />(IDC) CONFIGURATION: <br />UL LISTED <br />COMPATIBLE <br />CONTROL SIGNAL LINE CIRCUIT (SLC) <br />PANEL (+) <br />TO <br />(_) NE <br />f � NEXT <br />DEVICE <br />ALL WIRING <br />SHOWN IS <br />SUPERVISEDAND TENS ONES <br />POWER LIMITED (-) W W (-) <br />47k EOL <br />INCLUDED <br />(ELR-47k) <br />C0614-02 <br />C1063-00 <br />FL-460-004 1 I56-3654-002 <br />102008 FireLite Alarms Inc. <br />