My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1302 SE EVERETT MALL WAY TRADER JOES 2025-08-07
>
Address Records
>
SE EVERETT MALL WAY
>
1302
>
TRADER JOES
>
1302 SE EVERETT MALL WAY TRADER JOES 2025-08-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/7/2025 11:40:35 AM
Creation date
4/24/2025 2:10:40 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1302
Tenant Name
TRADER JOES
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
526
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SYSTEM SPECIFICATIONS <br />Primary (AC) Power: <br />• FL-PS6(C): 120 VAC, 50/60 Hz, 5.OA maximum <br />• FL-PS10(C): 120VAC, 50/60 Hz, 6.2 A maximum <br />• Wire Size: #12-14 AWG with 600 V insulation <br />Command Input Circuit: <br />• Trigger Input Voltage: 9 to 32 VDC <br />• Trigger Current: 2.0 mA (16 - 32 V); Per Input: 1.0 mA (9 - 16 V) <br />Trouble Contact Rating: 4 A at 24 VDC <br />Output Circuits: <br />• 24 VDC filtered, regulated <br />• FL-PS6: TB8-T139 — 1A Regulated, 3A special applications; <br />TB10-TB12 — 0.3A Regulated, 3A special applications <br />• FL-PS10: TB8-TB11 — 1.5A Regulated, 3A special applications; <br />TB12-TB14 — 0.3A Regulated, 3A special applications <br />• 6.0 A (FL-PS6) or 10.0 A (FL-PS10) maximum total continuous <br />current for all outputs <br />Secondary Power (Battery) Charging Circuit: <br />• Supports lead -acid batteries only <br />• Float -charge voltage: 27.6 VDC <br />• Maximum current charge: 1.5 A <br />• Maximum battery capacity: 18 AH (inside cabinet) <br />• Maximum battery charging capacity: 33 AH (external cabinet) <br />Physical: <br />• Dimensions: 20.0"H x 14.5"W x 3.5"D (cm: 50.8H x 36.83W x <br />8.9D) <br />• Weight: with two 7Ah batteries is 24 pounds (10.9 kg), with two <br />18AH batteries is 39 pounds (17.7 kg) <br />Ordering Information <br />FL-PS6: 6.0 A, 120 VAC remote charger power supply in a lock- <br />able, metal enclosure <br />FL-PS6C: Same as above, ULC-listed model <br />FL-PS10: 10.0 A, 120 VAC remote charger power supply in a lock- <br />able, metal enclosure <br />FL-PS10C: Same as above, ULC-listed model <br />ZNAC-PS: Optional Class A output converter module <br />CMF-300: Addressable Control Module for one Class B or Class A <br />zone of supervised, polarized Notification Appliances. Notification <br />Appliance Circuit option requires external 24 VDC to power notifica- <br />tion appliances. <br />CRF-300: Addressable relay module containing two isolated sets of <br />Form-C contacts, which operate as a DPDT switch <br />MMF-300: Addressable Monitor Module for one zone of normally <br />open dry -contact initiating devices. Includes plastic cover plate and <br />end -of -line resistor. Module may be configured for either a Class B <br />or Class A IDC. <br />MDF-300: Dual Monitor Module. Same as MMF-300 except it pro- <br />vides two inputs for Class B wiring only <br />CDRM-300: Provides two monitored inputs and two Form-C relays. <br />Functions in Class B wiring only. <br />CMF-300-6: Six -circuit supervised control module <br />CRF-300-6: Six Form-C relay control module <br />EOLR-1: 12/24 VDC end -of -line relay for monitoring four -wire <br />smoke detector power <br />BAT-1270-BP: Battery, 12 volt, 7.0 AH, 5-pack (two required). <br />BAT-12180-BP: Battery, 12 volt, 18AH, 2-pack <br />BAT-12330: Battery, 12 volt, 33AH <br />SEISKIT-MULTI-1: Seismic kit for the FL -PS Series. Includes <br />bracket and hardware for two 7AH or two 18AH batteries. <br />Fire-Lite® Alarms and System Sensor® are registered trademarks of Honeywell <br />International, Inc. Wheelock® is a registered trademark of Cooper Technologies <br />Company. Gentex® is a registered trademark of Gentex Corporation. AMSECO® is <br />a registered trademark of Potter Electric Signal Company, LLC. ANSI® is a <br />registered trademark of the American National Standards Institute, Inc. <br />02020 by Honeywell International Inc. All rights reserved. Unauthorized use of this <br />document is strictly prohibited. <br />This document is not intended to be used for installation purposes. <br />ISO 9oo1 We try to keep our product information up-to-date and accurate. <br />We cannot cover all specific applications or anticipate all requirements. <br />All specifications are subject to change without notice. <br />ENGINEERING 9 MANUFACTURING <br />Q U A t I T Y SYSTEMS For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. Country of Origin: USA <br />www.firelite.com <br />Page 2 of 2 — DF-61093:B • 1/6/2021 <br />
The URL can be used to link to this page
Your browser does not support the video tag.