Laserfiche WebLink
Technical Data TD450157EN <br />EffectiveApril 2021 <br />Eluxa horns, horn strobes & strobes <br />Table 5. Specifications <br />Physical <br />Material Red or white textured UV stabilized, colored impregnated engineered plastic. Exceeds 94V-0 UL flammability rating <br />Weight Wall: 0.35 Ibs; Ceiling: 0.55 Ibs <br />Lens Light Emitting Diode (LED) in a rugged Lexan lens <br />Dimensions Wall: 4.79"H x 2.76" W x 1.18" D, Trimplate: 5.25" H x 4.58" W x 0.32" D; Ceiling: 6.27" Diameter x 1.69" 0 <br />Operating Temperature Indoor: 32°F to 122°F WC to 50°C) and maximum humidity of 93% <br />Mounting & Wire Connections <br />Mounting (indoor only) Mounting plate included with all models. ELHS and ELST are for wall -mount applications only. ELHN can be used for <br />wall and ceiling -mount applications. Wall mounting: Single -gang, ELSBB backboxes or to 4" square with adapter kit. <br />ELHN can be used for wall and ceiling -mount applications. ELHSC and ELSTC are for ceiling mount applications only. <br />The ELHNC can also be used for wall -mount applications. Ceiling mounting: LSPKBB-C backboxes or to 4" square, 1 <br />1/2" or 2 1/8"and Octagonal, 1 %z" or 2 1/8"deep <br />Wire Connections #12 through #18 AWG <br />Power & General <br />Operating voltage 12 VDC/VFWR: 8 - 17.5 VDC/VFWR; 24 VDCNFWR: 16 - 33 VDCNFWR (12 VDC ELHN/ELHNC models only) <br />Strobe Output Rating UL 1971, UL 1638, ULC S526: Selectable 15, 30, 75, 110, 135, 185 candela output for wall models; Selectable 15, 30, 75, <br />110, 150, 177 candela output for ceiling models <br />Synchronization Models Strobes can be synchronized with Wheelock's DSM Sync Modules, PS Power Supplies or SAFEPATH products, using <br />Wheelock patented sync protocol <br />Architects and Engineers Specifications <br />The LED notification appliances shall be Wheelock® ELHS audible <br />visual strobe appliances, ELST visual strobe appliances and ELHN <br />audible appliances for wall and ceiling -mount applications with a low - <br />profile design or approved equals. Special lettering, including AGENT, <br />ALERT, EVACUATE, and no lettering, shall be available. The ELHS <br />and ELST strobes shall be listed for UL Standard 1971 (Emergency <br />Devices for the Hearing -Impaired) for Indoor Fire Protection Service <br />and UL 1638 (Visible Signaling Devices. The ELHS and ELHN <br />Audibles shall be UL Listed under Standard 464 (Fire Protective <br />Signaling). All models shall meet the requirements of FCC Part 15 <br />and ICES-003. All inputs shall be compatible with standard reverse <br />polarity supervision of circuit wiring by a Fire Alarm Control Panel <br />(FACP) with the ability to operate from 16 to 33 VDCNFWR. <br />The ELHS audible strobe and ELST strobe appliances shall produce <br />a flash rate of one (1) flash per second over the Regulated Voltage <br />Range and shall incorporate a Light Emitting Diode (LED) as the <br />light source with a rugged Lexan® lens. The appliances shall be of <br />low current design. The LED strobe flash duration shall be 20 ms. <br />Where Multi -Candela appliances are specified, the strobe intensity <br />shall have 6 field selectable settings at 15, 30, 75, 110, 135 and 185 <br />candela for wall mount applications and 15, 30, 75, 110, 150 and 177 <br />for ceiling applications. The selector switch for selecting the candela <br />shall be tamper resistant. Appliances with candela settings shall <br />show the candela selection in a visible location at all times when <br />installed. <br />The audible shall have a choice of three (3) horn patterns (high & low <br />WE ENCOURAGE AND SUPPORT NICET CERTIFICATION <br />3 YEAR WARRANTY <br />Eaton <br />1000 Eaton Boulevard <br />Cleveland, OH 44122 <br />United States <br />Eaton.com <br />Life safety & mass notification solutions <br />273 Branchport Ave. <br />-�� <br />Long Branch, NJ 07740 <br />Powering Business Worldwide <br />Eaton.com/Lifesafetynotification <br />output): Continuous, T3, and T3/T4 for fire (T3) and CO (T4) signaling <br />The ELHS audible strobe, ELST strobe, and ELHN audible shall <br />include a hinged mounting plate. Mounting options shall include <br />LED backboxes, single -gang backbox and to 4" square with adapter <br />kit for wall -mount models and LED Ceiling backboxes, 4" square, 1 <br />1/2" or 2 1/8"deep and 4" Octagonal, 1 1/2" or 2 1/8"deep for ceiling <br />models. Two wire appliance wiring shall be capable of directly <br />connecting to the mounting base. Removal of an appliance shall <br />result in a supervision fault condition by the Fire Alarm Control Panel <br />(FRCP). All notification appliances shall be backwards compatible. <br />The ELHS, ELHN and ELST wall models shall have a low profile <br />measuring 4.79"H x 2.76"W x 1.18"D. The ELHSC, ELHNC and <br />ELSTC ceiling models shall have a low profile measuring 6.27" <br />Diameter with 1.69"D. <br />When synchronization is required, the appliance shall be compatible <br />with Wheelock®'s DSM Sync Modules, PS Power Supplies, <br />SAFEPATH products or other manufacturer's panels with built-in <br />Wheelock® Patented Sync Protocol. The strobes shall not drift out <br />of synchronization at any time during operation. If the sync protocol <br />fails to operate, the strobe shall revert to a non -synchronized flash - <br />rate and still maintain (1) flash per second over its Regulated Voltage <br />Range. The appliance shall also be designed so that the audible <br />signal may be silenced while maintaining strobe activation when <br />used with Wheelock® patented sync protocol. <br />NFPA 72 2016, UL 1971, UL, 1638, UL 464 ULC-S525-16, ULC-S526- <br />16, CSFM, FCC, RoHS, ICES <br />© 2021 Eaton <br />All Rights Reserved <br />Printed in USA <br />Publication No. TD450157EN <br />April 2021 <br />Eaton is a registered trademark. <br />All other trademarks are property <br />of their respective owners. <br />