My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1202 E CASINO RD 2025-07-31
>
Address Records
>
E CASINO RD
>
1202
>
1202 E CASINO RD 2025-07-31
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2025 9:02:32 AM
Creation date
4/24/2025 3:55:30 PM
Metadata
Fields
Template:
Address Document
Street Name
E CASINO RD
Street Number
1202
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
209
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
6. Place flaring tool onto the form. Instructions for Connecting Piping to <br /> 7. Turn the handle of the flaring tool clockwise Indoor Unit <br /> until the pipe is fully flared. <br /> 8. Remove the flaring tool and flare form, then 1. Align the center of the two pipes that you will <br /> inspect the end of the pipe for cracks and connect. See Fig. 5.7 . <br /> even flaring. AIM r. <br /> Step 4: Connect pipes 0 <br /> When connecting refrigerant pipes, be careful I <br /> not to use excessive torque or to deform the <br /> piping in any way. You should first connect the Indoor unit tubing Flare nut Pipe <br /> low-pressure pipe, then the high-pressure pipe. Fig. 5.7 <br /> MINIMUM BEND RADIUS 2. Tighten the flare nut as tightly as possible by <br /> When bending connective refrigerant piping, hand. <br /> the minimum bending radius is 10cm. See 3. Using a spanner, grip the nut on the unit <br /> Fig..5.6 tubing. <br /> 4. While firmly gripping the nut on the unit <br /> IOV"*, tubing, use a torque wrench to tighten the <br /> ,+''»,4 flare nut according to the torque values in the <br /> AP/. <br /> *4% <br /> Torque Requirements table below. Loosen <br /> the flaring nut slightly, then tighten again. <br /> ea 110 <br /> lira Radius >_10cm (4in) ,r <br /> At" 11 <br /> it. 'ilk <br /> LER 40'w will <br /> ll <br /> A k��0. I <br /> n 73 <br /> 313- <br /> 3-p'-- <br /> n 3 0 <br /> Fig. 5.6 Fig. 5.8 0 <br /> TORQUE REQUIREMENTS <br /> Outer Diameter of Pipe (mm) Tightening Torque (N•cm) Add. Tightening Torque (N•cm <br /> O 6.35 (0 0.25") 1,500 (111b•ft) 1,600 (11.81b•ft) <br /> 0 9.52 (0 0.375") 2,500 (18.41b•ft) 2,600(19.181b•ft) <br /> O 12.7 (0 0.5") 3,500(25.81b•ft) 3,600(26.551b•ft) <br /> O 16(0 0.63") 4,500(33.191b•ft) 4,700 (34.671b•ft) <br /> O 19(0 0.75") 6,500(47.941b•ft) 6,700 (49.421b•ft) <br /> 0 DO NOT USE EXCESSIVE TORQUE <br /> Excessive force can break the nut or damage the refrigerant piping. You must not exceed torque <br /> requirements shown in the table above. <br /> 411 Page 27 10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.