Laserfiche WebLink
Test Run <br /> Before Test Run List of Checks to Perform PASS✓FAIL <br /> Only perform test run after you have completed No electrical leakage <br /> the following steps: <br /> Unit is properly grounded <br /> • Electrical Safety Checks— Confirm that <br /> the unit's electrical system is safe and <br /> operating properly All electrical terminals <br /> properly covered <br /> • Gas Leak Checks— Check all flare nut <br /> connections and confirm that the system is Indoor and outdoor units <br /> not leaking are solidly installed <br /> • Confirm that gas and liquid (high and low <br /> pressure) valves are fully open All pipe connection Outdoor Indoor <br /> points do not leak (2): (2): <br /> Test Run Instructions Water drains properly <br /> from drain hose <br /> You should perform the Test Run for at least 30 <br /> minutes. All piping is properly <br /> insulated <br /> 1. Connect power to the unit. <br /> 2. Press the ON/OFF button on the remote Unit performs COOL <br /> controller to turn it on. function properly <br /> 3. Press the MODE button to scroll through the Unit performs HEAT <br /> following functions, one at a time: function properly <br /> • COOL— Select lowest possible temperature <br /> • HEAT— Select highest possible temperature Indoor unit louvers <br /> 4. Let each function run for 5 minutes, and rotate properly <br /> perform the following checks: Indoor unit responds to <br /> remote controller <br /> m <br /> 41 Page 32 ► <br />