My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5631 EVERGREEN WAY ROYAL MEATS 2025-06-25
>
Address Records
>
EVERGREEN WAY
>
5631
>
ROYAL MEATS
>
5631 EVERGREEN WAY ROYAL MEATS 2025-06-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/25/2025 2:03:44 PM
Creation date
4/25/2025 8:35:42 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
5631
Tenant Name
ROYAL MEATS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Drew Martin <br /> From: Drew Martin <br /> Sent: Wednesday, August 24, 2022 10:00 AM <br /> To: Michelle Leszcynski <br /> Cc: George Tsai; Sue Genty <br /> Subject: RE: [EXTERNAL] RE: City of Everett Permit Services: 5631 Evergreen Way (132206-011) - <br /> Second Building Review <br /> Attachments: IMG 1777.JPG <br /> Thank you for the update. Based on this response,this email will serve as the Building correction letter. Please resubmit <br /> two new full-size copies of the revised drawings. The following should be addressed in the drawings: <br /> 1. Update drawings as needed to heat the second floor. Level should be insulated per current code requirements, <br /> including the floor separating the space from the level below. Interior doors separating heating and unheated <br /> space should be exterior doors with the required thermal ratings. Existing doors and windows should be <br /> upgraded if they do not comply with current code requirements. <br /> 2. Energy credits should be specified per WSEC Chapter 4. A list of credits and the performance requirements <br /> should be specified. Where selected credits require upgrades to the insulation,the thermal values should be <br /> revised; do not specify both default and improved values. <br /> 3. Sheet AO should be revised to incorporate the redline edits shown in the attached photo. <br /> 4. The project includes windows, including in the doors,that require safety glazing. All safety glazing should be <br /> specified in the drawings. <br /> 5. Windows in doors should comply with ICC A117.1-09 Section 404.2.10; windows should not be higher than 43 <br /> inches above the finished floor. <br /> 6. The structural sheets should be revised to remove all structural calculations. Only details required for <br /> construction should be included. Based on a review of the drawings, only the Plan and Details 1 and 2 on Sheet <br /> S1 are required. Improved quality reproductions should be used. The plan is not legible and should be enlarged. <br /> I will be out of the office. Please contact another reviewer if you have questions. <br /> — Drew Martin, P.E.,S.E. <br /> Associate Engineer—Commercial Plans Examiner I Permit Services <br /> 425.257.8810 13200 Cedar Street, 2nd Floor, Everett, WA 98201 <br /> EVERETT Phone Hours: M/W/T: 8 am - 12 pm & 1 pm—3 pm;Tu: 1:OOpm-3:OOpm <br /> everettwa.gov/permits I Facebook I Twitter <br /> Note:Emails and attachments sent to and from the City of Everett are public records and may be subject to disclosure pursuant to the Public <br /> Records Act. <br /> From: Michelle Leszcynski <michelle@sgidinc.com> <br /> Sent: Wednesday,August 24, 2022 9:42 AM <br /> To: Drew Martin <dmartin@everettwa.gov> <br /> Cc:George Tsai<george.tsai@royalmeatllc.com>; Sue Genty<sue@sgidinc.com> <br /> Subject: RE: [EXTERNAL] RE: City of Everett Permit Services: 5631 Evergreen Way(132206-011)-Second Building Review <br /> Hi Drew <br /> I discussed it with the client and the break room, office space and restrooms do need to be built out with this build-out. <br /> 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.