Laserfiche WebLink
17 of 34 <br /> NI`TI <br /> Hilti PROFIS Engineering 3.0.75 <br /> www.hilti.com <br /> Company: Otak,Inc. Page: 7 <br /> Address: Specifier: <br /> Phone I Fax: I E-Mail: <br /> Design: BRT Shelter Windscreen Retrofit-Short Direction Date: 2/3/2022 <br /> Fastening point: <br /> 4.2 Pryout Strength <br /> (Bond Strength controls) <br /> Vspg =kc [(ANa \ Wec1,Na Wec2,Na Wed,Na Nba ] ACI318-14Eq.(17.5.3.1b) <br /> ANaO <br /> • VC,9 >Voa ACI 318-14 Table 17.3.1.1 <br /> ANa see ACI 318-14,Section 17.4.5.1,Fig.R 17.4.5.1(b) <br /> ANaO =(2 CNa)2 ACI 318-14 Eq.(17.4.5.1c) <br /> CNa =10 da V T uncr ACI 318-14 Eq.(17.4.5.1d) <br /> 1100 <br /> 1 <br /> ec,Na = �1 + eN <1.0 ACI 318-14 Eq.(17.4.5.3) <br /> CNa <br /> W ed,Na =0.7+0.3 ( min) <1.0 ACI 318-14 Eq.(17.4.5.4b) <br /> CNa <br /> cpNa =MAX(Cmin CNa) �1.0 ACI 318-14 Eq.(17.4.5.5b) <br /> Cac Cac <br /> Nba =X a'tk,c' it'da' hef ACI 318-14 Eq.(17.4.5.2) <br /> Variables <br /> kg, aoverhead t [psi] da[in.] her[in.] c [in.] [psi] <br /> k,c uncr a,min k,c <br /> 2 1.000 2,327 0.500 4.000 1,190 <br /> ec1,N[in.] ec2,N[in.] cac[in.] A.a <br /> 0.000 0.000 10.058 1.000 <br /> Calculations <br /> CNa[in.] ANa[in.2] ANao[in.2] W ed,Na <br /> 7.239 364.67 209.62 1.000 <br /> ec1,Na Wec2,Na Wcp,Na Nba[lb] <br /> 1.000 1.000 1.000 7,475 <br /> Results <br /> "cm[lb] 4)concrete • Vc2OIb] Vua[lb] <br /> 26,006 0.700 18,204 265 <br /> 5 Combined tension and shear loads <br /> aN 13v Utilization(3Nv Status <br /> 0.500 0.021 5/3 32 OK <br /> RNV=IN+I <=1 <br /> Input data and results must be checked for conformity with the existing conditions and for plausibility! <br /> PROFIS Engineering(c)2003-2022 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan <br /> 7 <br /> /7/tea <br />