My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5002 EVERGREEN WAY SWIFT 2025-07-21
>
Address Records
>
EVERGREEN WAY
>
5002
>
SWIFT
>
5002 EVERGREEN WAY SWIFT 2025-07-21
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/21/2025 1:56:20 PM
Creation date
4/28/2025 7:33:32 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
5002
Tenant Name
SWIFT
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 of 34 <br /> I■■11`TI <br /> Hilti PROFIS Engineering 3.0.75 <br /> www.hilti.com <br /> Company: Otak,Inc. Page: 1 <br /> Address: Specifier: <br /> Phone I Fax: I E-Mail: <br /> Design: BRT Shelter Windscreen Retrofit-Long Direction Date: 2/3/2022 <br /> Fastening point: <br /> Specifier's comments: <br /> 1 Input data ...._. F <br /> Anchor type and diameter: HIT-HY 200+HAS-V-36(ASTM F1554 Gr.36)1/2 <br /> Item number: 2198022 HAS-V-36 1/2"x6-1/2"(element)/2022791 <br /> HIT-HY 200-A(adhesive) <br /> Effective embedment depth: het,act=4.000 in.(het,i=it=-in.) <br /> Material: ASTM F1554 Grade 36 <br /> Evaluation Service Report: ESR-3187 <br /> Issued I Valid: 5/1/2021 13/1/2022 <br /> Proof: Design Method ACI 318-14/Chem <br /> Stand-off installation: eb=0.000 in.(no stand-off);t=0.500 in. <br /> Anchor plateR: Ix x ly x t=4.500 in.x 10.000 in.x 0.500 in.;(Recommended plate thickness:not calculated) <br /> Profile: Rectangular HSS(AISC),HSS4X3X.250;(L x W x T)=4.000 in.x 3.000 in.x 0.250 in. <br /> Base material: cracked concrete,4000,fc'=4,000 psi;h=6.000 in.,Temp.short/long:32/32°F <br /> Installation: hammer drilled hole,Installation condition:Dry <br /> Reinforcement: tension:condition B,shear:condition B;no supplemental splitting reinforcement present <br /> edge reinforcement:none or<No.4 bar <br /> R-The anchor calculation is based on a rigid anchor plate assumption. <br /> Geometry[in.]&Loading[Ib,ft.lb] <br /> l l Design loads <br /> Sustained loads I <br /> a <br /> 4 <br /> t '0 <br /> V <br /> ilii.),„„„-A---r-i��� a <br /> � / <br /> t��tzs <br /> Z <br /> f '! <br /> Y <br /> X <br /> Input data and results must be checked for conformity with the existing conditions and for plausibility! <br /> PROFIS Engineering(c)2003-2022 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan <br /> 1 <br /> 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.