My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6729 EVERGREEN WAY SWIFT 2025-07-21
>
Address Records
>
EVERGREEN WAY
>
6729
>
SWIFT
>
6729 EVERGREEN WAY SWIFT 2025-07-21
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/21/2025 2:01:33 PM
Creation date
4/28/2025 11:34:05 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
6729
Tenant Name
SWIFT
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
8of34 <br /> F111I`TI <br /> Hilti PROFIS Engineering 3.0.75 <br /> www.hilti.com <br /> Company: Otak,Inc. Page: 8 <br /> Address: Specifier: <br /> Phone I Fax: E-Mail: <br /> Design: BRT Shelter Windscreen Retrofit-Long Direction Date: 2/3/2022 <br /> Fastening point: <br /> 6 Warnings <br /> • The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations(AS 5216:2021,ETAG 001/Annex C, <br /> EOTA TR029 etc.).This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered-the <br /> anchor plate is assumed to be sufficiently stiff,in order not to be deformed when subjected to the design loading.PROFIS Engineering calculates <br /> the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions explained above.The <br /> proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering.Input data and results must be checked for <br /> agreement with the existing conditions and for plausibility! <br /> • Condition A applies where the potential concrete failure surfaces are crossed by supplementary reinforcement proportioned to tie the potential <br /> concrete failure prism into the structural member.Condition B applies where such supplementary reinforcement is not provided,or where pullout <br /> or pryout strength governs. <br /> • Design Strengths of adhesive anchor systems are influenced by the cleaning method.Refer to the INSTRUCTIONS FOR USE given in the <br /> Evaluation Service Report for cleaning and installation instructions. <br /> • For additional information about ACI 318 strength design provisions,please go to https://submittals.us.hilti.com/PROFISAnchorDesignGuide/ <br /> • Installation of Hilti adhesive anchor systems shall be performed by personnel trained to install Hilti adhesive anchors.Reference ACI 318-14, <br /> Section 17.8.1. <br /> Fastening meets the design criteria! <br /> Input data and results must be checked for conformity with the existing conditions and for plausibility! <br /> PROFIS Engineering(c)2003-2022 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan <br /> 8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.