Laserfiche WebLink
2of34 <br /> 1■■11`.TI <br /> Hilti PROFIS Engineering 3.0.75 <br /> www.hilti.corn <br /> Company: Otak, Inc. Page: 2 <br /> Address: Specifier: <br /> Phone I Fax: I E-Mail: <br /> Design: BRT Shelter Windscreen Retrofit-Long Direction Date: 2/3/2022 <br /> Fastening point: <br /> 1.1 Design results <br /> Case Description Forces[Ib]/Moments[ft.lb] Seismic Max.Util.Anchor[%] <br /> 1 Long Direction N=0;Vx=0;Vy=314; no 31 <br /> Mx=-1,125.000;My=0.000;Mz=0.000; <br /> N5u5=0;Mx.s55=0.000;My 555=0.000; <br /> 2 Load case/Resulting anchor forces •�v I <br /> (pressite 4 <br /> Anchor reactions[Ib] <br /> Tension force:(+Tension,-Compression) <br /> Anchor Tension force Shear force Shear force x Shear force y <br /> 1 872 78 0 78 <br /> 2 872 78 0 78 �x <br /> 3 0 78 0 78 <br /> 4 0 78 0 78 <br /> max.concrete compressive strain: 0.08[%a] <br /> max.concrete compressive stress: 339[psi] <br /> resulting tension force in(x/y)=(-0.000/-3.500): 1,745[Ib] 1 ��J 2 <br /> resulting compression force in(x/y)=(0.000/4.238): 1,745[Ib] Tension <br /> Anchor forces are calculated based on the assumption of a rigid anchor plate. <br /> 3 Tension load <br /> Load N.[Ib] Capacity$ Nn[Ib] Utilization PN=Nua/$ Nn Status <br /> Steel Strength* 872 6,172 15 OK <br /> Bond Strength** 1,745 5,697 31 OK <br /> Sustained Tension Load Bond Strength* N/A N/A N/A N/A <br /> Concrete Breakout Failure** 1,745 6,756 26 OK <br /> *highest loaded anchor **anchor group(anchors in tension) <br /> Input data and results must be checked for conformity with the existing conditions and for plausibility! <br /> PROFIS Engineering(c)2003-2022 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan <br /> 2 <br />