My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7800 EVERGREEN WAY HYUNDAI 2025-08-05
>
Address Records
>
EVERGREEN WAY
>
7800
>
HYUNDAI
>
7800 EVERGREEN WAY HYUNDAI 2025-08-05
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/5/2025 2:25:26 PM
Creation date
4/28/2025 2:17:04 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
7800
Tenant Name
HYUNDAI
Imported From Microfiche
No
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2413
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
E V E R E T T August 31, 2022 <br /> WASHINGTON Richard Kennedy <br /> RKennedy@freiheitarch.com <br /> Freiheit Architects <br /> 777 108th Ave NE, STE 1650 <br /> Bellevue, WA 98004 <br /> Owner: LMJ Enterprises <br /> Project Address: 7800 Evergreen Way <br /> Plan Check No: B2204-005 <br /> RE: Building Permit Review Letter <br /> Dear Richard, <br /> In response to the application for a building permit, the plans have been <br /> examined and you are advised that revisions may be necessary before a permit <br /> can be issued. Please review and respond to the comments below. <br /> ARCHITECTURAL <br /> 1. On Sheet A3.08, it is unclear if the battery storage room is intended to <br /> contain enough batteries such that the incidental use of Table 509 is triggered. <br /> Please confirm or clarify as it may require providing 1 hour fire resistive <br /> construction to the room and ceiling. IBC 509. <br /> STRUCTURAL <br /> 1. On Sheet S2.0, it Is unclear if the wall along Grid 5 between Grids J, K and <br /> possibly further east is intended to be a shear wall. It appears to be a drafting <br /> error or rendering issue on the plans given that there is a shear wall callout of 4. <br /> Also,the same condition of rendering may be occurring along Grid K between <br /> Grids 3 &5 for shear walls (a callout of 3) resisting in the North-South direction. <br /> Please clarify extents and rendering of the wall and revised plans as required. <br /> IBC 107.2.1. <br /> RESUBMITTAL REQUIREMENTS <br /> In order for the processing of your application to continue, it will be necessary <br /> to provide the Building Division with the following items: <br /> PERMIT SERVICES (2) New, complete sets of revised construction documents reflecting <br /> the corrections as required. <br /> O3200 Cedar Street ❑ (1) Response letter detailing how the corrections were resolved. <br /> Everett,WA 98201 <br /> All codes cited refer to the 2018 International Building Code (IBC), 2018 <br /> O425.257.8810 International Existing Building Code (IEBC),the 2018 International Fire Code <br /> 425.257.8857 fax <br /> (IFC), the 2018 International Mechanical Code (IMC), and/or the 2018 <br /> everetteps@everettwa.gov Washington State Energy Code (WSEC), as amended by the State of Washington <br /> ''" everettwa.gov/permits and adopted by the City of Everett. The current IBC referenced standard for <br /> Page 1 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.