My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7800 EVERGREEN WAY HYUNDAI 2025-08-05
>
Address Records
>
EVERGREEN WAY
>
7800
>
HYUNDAI
>
7800 EVERGREEN WAY HYUNDAI 2025-08-05
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/5/2025 2:25:26 PM
Creation date
4/28/2025 2:17:04 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
7800
Tenant Name
HYUNDAI
Imported From Microfiche
No
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2413
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
BUILDING ENERGY Washington State 6 <br /> 111 TOTAL SYSTEM TSPR Analysis <br /> PERFORMANCE <br /> RATIO <br /> U.S. DEPARTMENT OF ENERGY Baseline HVAC System Description <br /> Building ID #: 25671 Gross Floor Area - small-office: 2790 ft2 <br /> The following section documents the baseline HVAC system which is added by the TSPR tool for the baseline <br /> simulation run. the baseline system is as specified in the 2018 Washington State Energy Code <br /> HVAC System System Controls <br /> DCV No <br /> Block(s)Served Block 1 Energy Recovery Ventilation <br /> Primary Heating/Cooling System Packaged Rooftop Heat Pump ERV Yes <br /> Ventilation System Dedicated Outdoor Air System ERV Sensible Effectiveness-Heating 0.7 <br /> Primary Heating/Cooling System ERV Latent Effectiveness-Heating 0.0 <br /> ERV Sensible Effectiveness-Cooling 0.7 <br /> System Type Packaged Rooftop Heat Pump <br /> ERV Latent Effectiveness-Cooling 0.0 <br /> Cooling Source Central DX <br /> ERV Economizer Bypass No <br /> Cooling Efficiency 3.83 COP <br /> ERV Supply Air Temperature Control No <br /> Heating Source Heat Pump <br /> System Fan Power Reduction when ERV0.0 W/CFM <br /> Heating Efficiency 3.81 COP Bypassed <br /> Fuel Type Electricity <br /> Condenser Type Air <br /> Distribution Equipment <br /> Distribution Type Single Zone <br /> Total System Fan Power(W/CFM) 0.528 W/CFM <br /> Fan Control Constant Volume <br /> System Controls <br /> DCV No <br /> Economizer No <br /> Energy Recovery Ventilation <br /> ERV No <br /> Ventilation System <br /> System Type Dedicated Outdoor Air System <br /> Cooling Source No Cooling <br /> Heating Source No Heating <br /> Distribution Equipment <br /> Distribution Type Single Zone <br /> Total System Fan Power 0.819 W/CFM <br /> DOAS Bypass Air Temperature Setpoint NA <br /> Fan Control Constant Air Volume <br />
The URL can be used to link to this page
Your browser does not support the video tag.