Laserfiche WebLink
GENERAL NOTES <br />LEGAL DESCRIPTION <br />PROJECT DATA <br />CONSTRUCTION <br />1. ALL CONSTRUCTION SHALL COMPLY WITH THE 20181NTERNATIONAL BUILDING CODE AS ADOPTED BY <br />THE CRY OF EVERETT, STATE REGULATIONS FOR BARRIER FREE DESIGN, WA STATE ENERGYCODE, <br />AND ALL APPLICABLE LOCAL CODES, ORDINANCES, AND STANDARDS. IN CASE OF ANY CONFLICT WHERE <br />THE METHODS OR STANDARDS OF INSTALLATION OF THE MATERIALS SPECIFIED DO NOT EQUAL OR <br />EXCEED THE REQUIREMENTS OF THE LAWS OR ORDINANCES, THE LAWS OR ORDINANCES SHALL <br />GOVERN. NOTIFY THE ARCHITECT OF ALL CONFLICTS. <br />2. SECU RE RELEVANT CITY AND STATE APPROVALS RELATING TO FIRE, CONSTRUCTION, LABOR,HEALTH <br />AND LICENSING. CONTRACTOR SHALL FURTH ER POST ALL BON DS AND SECU RE ALL INSU RANCE <br />REQUIRED BY LAW OR CONTRACT, FORWARDING PROOF OF SUCH ACTIONS TO THE LANDLORD PRIOR <br />TO COMMENCEMENT OF CONSTRUCTION. <br />3. WORK NOT INCLU DED IN THIS CONTRACT SHALL BE MARKED "N.I.C"OR SPECIFICALLY ASSIGNED TO <br />ANOTHER PARTY. <br />4. CONTRACTOR SHALL VISIT THE SITE, REVIEW THE DRAWINGS AS SU BMITTED BY THE ARCHITECT,AND <br />BECOME THOROUGHLY FAMILIAR WITH THE SITE CONDITIONS PRIOR TO BIDDING OR CONSTRUCTION. <br />6. ALL WORK SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURERS LATEST <br />RECOMMENDATIONS OR WRITTEN DIRECTIONS. <br />6. WHERE CON STRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK,THE <br />DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. <br />7. WHERE DEVICES OR ITEMS OR PARTS THEREOF ARE REFERRED TO IN SINGULAR, IT IS INTENDED <br />THAT SUCH SHALL APPLYTO AS MANY SUCH DEVICES, ITEMS OR PARTS AS ARE REQUIRED TO <br />PROPERLY COMPLETE THE WORK. <br />8. VERIFYALL "BUILDING STANDARDS" WITH BUILDING OWNER PRIOR TO BEGINNING ANY WORK. <br />HOWEVER, THERE SHALL BE NO DEVIATIONS WHATSOEVER FROM THE CONTRACT DOCUMENTS <br />WITHOUT THE ARCHITECT'S WRITTEN APPROVAL THEREOF. THE CONTRACTOR AGREES TO DEFEN D, <br />INDEMNIFY, AND HOLD THE ARCHITECT HARMLESS FROM ANY CLAIMS ARISING AS A RESULT OF <br />UNAPPROVED CHANGES. <br />9. LOCATE ALL EXISTING UTILITIES WHETHER SHOWN HEREON OR NOT AND TO PROTECT TH EM FROM <br />DAMAGE. THE CONTRACTOR SHALL BEAR ALL EXPENSE OF REPAIR OR REPLACEMENT OF UTILITIES OR <br />OTHER PROPERTY DAMAGED BY OPERATIONS IN CONJUNCTION WITH THE EXECUTION OF THIS WORK. <br />10. VERIFYAND CON FORM TO ALL REQUIREMENTS OF ALL UTILITY COMPANIES UN LESS OTHERWISE <br />NOTED IN THE PLANS OR SPECIFICATIONS. <br />11. ALL DEBRIS SHALL BE REMOVED FROM PREMISES AND ALL AREAS SHALL BE LEFT IN A CLEAN <br />(BROOM) CONDITION AT ALL TIM ES. <br />12. PROTECT ADJACENT WORK AND REPAIR ANY DAMAGE AT CONTRACTOR'S OWN EXPENSE. <br />13. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY IN THE AREA OF WORK IN ACCORDANCE <br />WITH ALL APPLICABLE SAFETY CODES. <br />14. THE CONTRACTOR SHALL IN DEMNIFY AND HOLD THE BUILDING OWNER/ARCHITECT/ENGINEER <br />HARMLESS FOR INJURY OR DEATH TO PERSONS OR FOR DAMAGE TO PROPERTY CAUSED BYTHE <br />NEGLIGENCE OF THE CONTRACTOR, HIS AGENTS, EMPLOYEES, OR SUBCONTRACTORS. <br />i6. APPROVED PLANS SHALL BE KEPT IN A PLAN BOX AND SHALL NOT BE USED BY ANY WORKERS. ALL <br />CONSTRUCTION SETS SHALL REFLECT TH E SAME INFORMATION AS WELL AS ALL REVISIONS, ADDENDA, <br />AND CHANGE ORDERS. THE CONTRACTOR SHALL ALSO MAINTAIN IN GOOD CONDITION, ONE COMPLETE <br />SET OF PLANS WITH ALL REVISIONS, ADDENDA, AND CHANGE ORDERS, ON THE PREMISES AT ALL TIMES <br />WHICH ARE TO BE UNDER THE CARE OF THE JOB SUPERINTENDENT. <br />i6. MAINTAIN ALL EXIT PATHWAYS DURING CONSTRUCTION. <br />17. PROVIDE COMPLETE SECURITY OF THE TENANT SUITE WHILE JOBIS IN PROGRESS AND UNTIL THE <br />JOB IS COMPLETED. <br />18. AT COMPLETION OF THE WORK, REMOVE ALL DEBRIS FROM THE SITE, LEAVING SPACE CLEAN, WASH <br />ALL WINDOWS AND GLASS, POLISH ALL HARDWARE AND FIXTURES. REPLACE AND PATCH AREAS OF <br />CEILING DAMAGED DUE TO LIGHTING INSTALLATION OR MECHANICAL ADJUSTMENT. <br />19. MINIMIZE DISRUPTIONS OF BUILDING OCCUPANTS DUE TO NOISE, ODOR, FUMES, OR VIBRATION. AT <br />THE END OF CONSTRUCTION THE CONTRACTOR SHALL COMPLETELY CLEAN ALL AREAS SOILED BY <br />CONSTRUCTION ACTIVITIES INCLU DING THOSE IN WHICH NO WORK WAS DONE. <br />20. LATHING, PLASTER, AND GYPSUM WALL BOARD SYSTEMS SHALL CONFORM TO CHAPTER 26 OF THE <br />2018 LB.C. <br />21. ALL GLASS AND GLAZING SHALL COMPLY WITH CHAPTER 24 OF THE 2018 LB.C. AND THE U.S. <br />PRODUCT SAFETY COMMISSION: SAFETY STANDARDS FOR ARCHITECTURAL GLAZING MATERIALS (42 FR <br />1426: i6 CFR PART 1201). <br />22. VERIFYALL DOOR AND WINDOW ROUGH OPENING DIMENSIONS WITH DOOR AND WINDOW <br />MANUFACTURERS. <br />23. DISCREPANCIES BENVEEN EXISTING CONDITIONS AND CON STRUCTION DRAWING SHOULD BE <br />CALLED TO THE ATTENTION OF THE ARCHITECT. <br />24. CONSTRUCT WALLS PLUMB AND SQUARE WITH EXISTING STRUCTURE AND NEW CONSTRUCTION <br />UNLESS NOTED OTHERWISE. <br />26. COORDINATION: THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE VERIFICATION AND <br />COORDINATION OF TH E WOR K OF ALL TRAD ES TO ASSURE COM PLIAN CE W ITH TH E DRAW IN GS. <br />26. ANY DEVIATIONS FROM DIMENSIONED LOCATIONS MUST BE APPROVED BYTHE ARCHITECT <br />Uh�iIq�69C�P <br />1. ALL INFORMATION SHOWN ON THE DRAWINGS RELATIVE TO EXISTING CONDITIONS IS GIVEN AS THE <br />BEST PRESENT KNOWLEDGE BUT WITHOUT GUARANTEE OF ACCURACY. THE CONTRACTOR SHALL <br />VERIFY EXISTING CONDITIONS AND DIMENSIONS AND SHALL NOTIFY THE ARCHITECT OF ANY <br />DISCREPANCIES OR CONDITIONS ADVERSELYAFFECTING THE DESIGN PRIOR TO PROCEEDING WITH THE <br />WORK. <br />2. DIMENSIONS OF PLANS ARE TYPICAL TO THE CENTERLINE OF COLU MNS AND FIN ISH ED GWB FACE OF <br />PARTITIONS,UNLESS NOTED OTHERWISE. DOOR AND CASED OPEN INGS WITHOUT LOCATION <br />DIMENSIONS ARE TO BE FOUR (4) INCHES FROM THE FACE OF THE ADJACENT PARTITION OR CENTERED <br />BETWEEN PARTITION S.3. DO NOT SCALE DRAWINGS. THE CONTRACTOR SHALL USE DIMENSIONS <br />SHOWN ON THE DRAWINGS AND ACTUAL FIELD MEASUREMENTS. NOTIFYTHE ARCHITECT IF <br />DISCREPANCIES ARE FOUND. <br />CONSTRUCTION <br />1. INVESTIGATE AND VERIFY LOCATIONS OF EXISTING STRUCTURAL, PLUMBING, MECHANICAL, AND <br />ELECTRICAL ELEMENTS AND OTHER EXISTING CONDITIONS AND NOTIFY THE ARCHITECT OF ANY ANDACL <br />DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. <br />2. COORDINATE CON STRUCTION SCH EDUCING WITH THE BU ILDING OWN ER TO ALLOW ONGOING <br />OPERATION OF THE FACILITY DURING CONSTRUCTION. <br />3. PROVIDE BLOCKING AS REQUIRED FOR WALL AND CEILING MOUNTED ITEMS. <br />4. OFFSET STUDS WHERE REQUIRED SO THAT FINISH WALL SURFACES WILL BE FLUSH. <br />6. PROVIDE GALVANIC ISOLATION BENVEEN DISSIMILAR METALS. <br />6. PATCH AND REPAIR ALL EXISTING SURFACES AS REQUIRED BY DEMOLITION AND NEW CONSTRUCTION <br />TO RECEIVE NEW SCHEDULED FINISHES. ALL SURFACES ARE TO HAVE "LIKE-NEW"APPEARANCE. <br />7. STUD HEIGHT AND SPACING LIMITATION OF STEEL FRAMING COMPONENTS SHOULD BE IN <br />COMPLIANCE WITH ASTM C 764 FOR MAXIMUM DEFLECTION AND MINIMUM LATERAL LOADING <br />REQUIREMENTS. <br />8. ALL DEMOLISHED MATERIALS TO BE RECYCLED TO AN APPROVED RECYCLER. <br />PLUMBING, MECHANICAL &ELECTRICAL <br />1. PLUMBING, MECHANICAL, & ELECTRICAL DRAWINGS ARE TO BE SUBMITTED UNDER SEPARATE <br />PERMIT. <br />2. MECHANICAL &ELECTRICAL CONTRACTORS SHALL BE RESPONSIBLE TO MAINTAIN COMPLIANCE <br />WITH APPLICABLE CODES AND STANDARDS AND OBTAIN ALL NECESSARY PERMITS AND APPROVALS <br />3. MECHANICAL AND ELECTRICAL SYSTEMS SHALL BE BIDDER DESIGN/BUILD. THE CONTRACTOR SHALL <br />BE RESPONSIBLE FOR OBTAINING THE CORRESPONDING PERMITS FOR WORK. THE PROPOSED <br />SYSTEM DESIGN &METHOD OF OPERATION FOR ALL ROOMS SHALL BE REVIEWED AND APPROVED BY <br />THE TENANT PRIOR TO TH E START OF ANY WORK. <br />4. WHERE APPLICABLE, STRUCTURAL, PLUMBING, MECHANICAL, ELECTRICAL, AND FIRE PROTECTION <br />DRAWINGS AR E SU PPLE MENTARY TO TH ESE DRAWINGS. TH E CONTRACTOR SHALL NOTIFY TH E <br />ARCHITECT OF ALL DISCREPANCIES BENVEEN THE CONSULTANTS' DRAWINGS WITH A WRITTEN <br />REQUEST FOR CLARIFICATION. ANY WORK INSTALLED IN CONFLICT WITH THESE DRAWINGS OR <br />SPECIFICATIONS SHALL BE CORRECTED BYTHE CONTRACTOR AT NO EXPENSE TO THE BUILDING <br />OWNER, TENANT, OR ARCHITECT. <br />6. ALL CABLING AND WIRING NOT IN CONDUITS OR FULL SURROUND CABLE TRAYS SHALL HAVE A <br />FLAME SPREAD RATING OF LESS THAN 26 AND A SMOKE DEVELOPMENT RANGE OF LESS THAN 60. <br />[:19��D:IS�b9gU��il_U�:719�a9191RH11�:7�U1:71I91:�9�gR11��i���illbg���il���7.�b <br />7. ALL PLU MBING AND HVAC PIPE AND DUCTWORK IN PLENUM SHALL HAVE A FLAME SPREAD RATING <br />OF LESS THAN 26 AND A SMOKE DEVELOPMENT RANGE OF LESS THAN 60 <br />:u ■: :�� 1:. .:� 1 <br />1. SU BMITA LIST OF PROPOSED PRODUCT SU BMITTALS AND SHOP DRAWINGS TO THE OWNER FOR <br />APPROVAL PRIOR TO START OF CONSTRUCTION. <br />2. ALL PRODUCTS AND MATERIALS SPECIFIED IN THE DRAWINGS (WITH EXCEPTION TO SPECIFIC FINISH <br />COLORS AND FLOORING) ARE INTENDED TO BE ON AN "OR EQUAL" BASIS. ANY PROPOSED <br />SUBSTITUTIONS MUST BE SUBMITTED TO THE ARCHITECT IN WRITING FOR APPROVAL WITHOUT DELAY <br />OF SCHEDULE. <br />3. ALL WORK SHALL BE GUARANTEED FOR A PERIOD OF ONE (1) YEAR AFTER COMPLETION, UNLESS <br />OTHERWISE SPECIFIED, AND SHALL BE SO STATED IN CONTRACTOR'S WRITTEN PROPOSAL AND <br />AGREEMENT. ALL REPAIRS, CORRECTIONS, DISCREPANCIES, ETC., MUST BE MADE WITH OUT ANY <br />ADDITIONAL COST TO THE OWNER, AND WITHIN FIVE (6) DAYS AFTER NOTICE IS GIVEN. <br />FIRE PROTECTION <br />iAy1:7i9:i�ilxNlC�]ICU:L\ry111RH.y9:7i[�1:1x.Y11:l��illrf Iq�1111U1q:=.9�99:LUi9q:7��i111 <br />2. IF NECESSARY, PROVIDE FIRE PROTECTION AT ALL PENETRATIONS OF FIRE RELATED ELEMENTS AS <br />REQUIRED BY CODE. <br />3. FIRE EXTINGUISHERS: VERIFY LOCATION, TYPE, AND SIZE PER FIRE MARSHAL REQUIREMENTS. <br />CONTRACTOR TO PROVIDE ALL TEMPORARYAND PERMANENT FIRE EXTINGUISHERS REQUIRED UNDER <br />N.F.P.A. 10 MOST RECENT EDITION AND APPROVED BYTHE FIRE MARSHAL. CONFIRM ACCEPTABILITY OF <br />LOCATION WITH FIRE MARSHAL PRIOR TO INSTALLATION. PROVIDE FINISHED CABINETS TO MATCH <br />BUILDING STANDARD FOR EXTINGUISHERS AT ALL EXPOSED LOCATIONS. <br />4. FIRE EXTINGUISH ERS AND CABIN ETS SHOULD BE LOCATED SO THAT THE TOP OF THE EXTINGUISH ER <br />OR CABINET IS NO HIGHER THAN 48" AFF AND THE TOP OF THE EXTINGUISHER OR CABINET HANDLE IS <br />AT L EAST 36" AFF. <br />6. ATSEMI-RECESSED FIRE EXTINGUISHER CABINETS WRAP ADDITIONAL LAYERS) OF TYPE'X' GYPSUM <br />WALL BOARD INTO THE CABINET CAVITY TO MAINTAIN SPECIFIED FIRE RATED REQUIREMENT. REFER TO <br />WALL CONSTRUCTION LEGEND FOR ADDITIONAL INFORMATION. <br />6. PROVIDE AND INSTALL FIRE EXTINGUISHER SIGNAGE (6"X6")ABOVE EACH FIRE EXTINGUISHER OR <br />CABINET WITH IN THE SCOPE OF THE TENANT IMPROVEMENT. MOUNT AT 84"AFF UNLESS OTH ERWISE <br />REQUIRED. <br />7. EXIT SIGNS AND EXIT ILLUMINATION SHALL CONFORM TO THE 201818C AND THE CITY OF EVERETT <br />FIRE MARSHAL REQUIREM ENTS. CONTRACTOR TO PROVIDE AND INSTALL EMERGENCY LIGHTING AND <br />EXIT LIGHTING AS REQUIRED BYTHE EVERETT FIRE AND BUILDING DEPARTMENTS. CONFIRM <br />ACCEPTABILITY OF LOCATIONS WITH THE BU ILDING OWN ER BEFOREINSTALLATION. CONTRACTOR <br />SHALL PROVIDE AND INSTALL AUDIBLE ALARMS IN ACCORDANCE WITH IBC ARTICLE 9. CONTRACTOR <br />SHALL PROVIDE AND INSTALL VISIBLE ALARM SIGNALS AS REQUIRED BYADA GUIDELINES. <br />CONTRACTOR SHALL PROVIDE AND INSTALL ALL SMOKE DETECTORS AND SMOKE DETECTION AS <br />REQUIRED UNDER ARTICLE 9 OF THE IBC. THE INSTALLATION OF THE ABOVE NOTED SYSTEM SHALL <br />INCLUDE THE CONNECTION TO AN D/OR MODIFICATION OF THE EXISTING BUILDING SYSTEMS, AS <br />NECESSARY. <br />8. EXIT DOORS SHALL BE OPENABLE FROM THEINSIDE WITH OUT THE USE OFA KEY OR ANY SPECIAL <br />KNOWLEDGE OR EFFORT. <br />9. FLAMMABLE LIQUIDS SHALL NOT BE PLACED, STORED, OR DISPENSED IN THIS OCCU PANCY EXCEPT <br />AS PROVIDED IN NFPA STANDARD 30 AND THE 20181NTERNATIONAL FIRE CODE. PERMIT MAY BE <br />REQUIRED. <br />10. ALL DRAPES, HANGINGS, CURTAINS,AND ALL OTHER DECORATIVE MATERIAL, INCLUDING <br />CH RISTMAS TREES THAT WOULD TEND TO INCREASE THE FIRE AND PANIC HAZARD SHALL BE MADE <br />FROM NONFLAMMABLE MATERIAL, OR SHALL BE TREATED AND MAINTAINED IN A FIRE RETARDANT <br />CONDITION BY MEANS OFA FLAME RETARDANT SOLUTION OR PROCESS APPROVED BYTHE FIRE <br />MARSHAL. PROVIDE A CERTIFICATION TO THIS EFFECT. EXIT DOORS, EXIT LIGHTS, AND FIRE <br />EXTINGUISHER LOCATIONS SHALL NOT BE CONCEALED OR OBSTRUCTED BYANY DECORATIVE <br />MATERIAL. MINIMUM FLAME SPREAD CLASSIFICATION OF INTERIOR FINISHES SHALL BE PER TABLE <br />803.9, SECTION 803.1 OF THE 201818C. <br />11. ALL REQUIRED FIRE DOORS SHALL BEAR A LABEL FROM A RECOGNIZED AGENCY SHOWING THE <br />SPECIFIC RATING. <br />CEILING <br />1. REFLECTED CEILING PLAN IS FOR THE GENERAL INFORMATION OF THE CONTRACTOR. EXACT <br />LOCATIONS SHOULD BE VERIFIED. <br />���: <br />1.ALL DOOR HARDWARE TO MEET REQUIREMENTS OF 201818C ANDOWNER'B BUILDING <br />REQUIREMENTS. <br />2. COORDINATE ALL KEYING REQUIREMENTS WITH OWN ER/TENANT. CONTRACTOR SHALL PROVIDE ALL <br />LOC KSET CYLINDERS TO MATCH OWNER STANDARD. CONTRACTOR SHALL RE-KEYALL DOORS TO MEET <br />TENANT AND OWNER'S REQUIREMENTS. <br />FINISH AND MATERIALS <br />1. SUBMIT FINISH SAMPLES TO TENANT AND OWNER FOR APPROVAL PRIOR TO ORDERING MATERIALS. <br />2. INTERSECTION OF SCHEDULED FLOORING MATERIALS ARE TO OCCUR AT CENTERLINE OF DOOR <br />WHEN IN A FU LLY CLOSED POSITION UNLESS NOTED OTHERWISE. <br />3. PROVIDE APPROPRIATE TRANSITION MATERIAL AS REQUIRED WHERE DISSIMILAR FLOORING <br />MATERIALS INTERSECT. <br />Section 07 Township 28 Range OS Quarter SW -TH PTN OF SWi/4 DAF - COM AT Wi/4 COR SD SEC TH N87'41 <br />47E ALG E-W C/LSD SEC 20FT TO E RNV LN OF BEVERLY LN TH S01'41 33E ALG SD E-W RNV LN 604.i6FT <br />THN88'42 29E PLW S LN SD SWi/4 794.64FT M/L TAP 460FT N WLY OF WH MEAS AT R/A TO MON C/L OF <br />EVERGREEN WAY& POB TH CONT N88'42 29E 470.93FT M/L TO NWLY RNV LN EVERGREEN WAY TH S30'33 <br />47W ALG SD NWLYRNV LN 312FT TH N86'26 OBW 444.97FT TAP ON SD LN PLW & 460FT NWLY OF <br />EVERGREEN WAY C/L BEAR S30'33 47W 268.39FT FR POB TH N30'33 47E 268.39FT TO POB & TGW TH PTN <br />THOF DAF -TH PTN SWi/4 DAF- COM ANVi/4 COR SD SEC TH N87'41 47E ALG E-W C/L SD SEC 20FT TO E <br />RNV OF BEVERLY LN TH S01'41 33E ALG SD E RNV LN 604.i6FT TH N88'42 29E 794.44FT TAP 460 FT NWLY <br />OF WH MEAS AT R/A TO MON C/L OF EVERGREEN WAY& TPB TH N30'33 47E PLT SD MON C/L 93.17FT TH <br />NBB'42 29E 470.93FT TO NWLY RNV OF EVERGREEN WAY TH S30'3347W ALG SD RNV 93.17FT TH SBB'42 <br />29W 470.93FT TO TP B (PE R CITY EVE BLA R EC AF N O 200109070661 & 200109076003) <br />DESCRIPTION OF WORK <br />REMODEL OF EXISTING SHOWROOM TO CURRENT HYUNDAI BRANDING STANDARDS. DEMOLITION OF THE <br />EXISTING SHOWROOM AND FRONT BUILDING FACADE TO ACCOMMODATE NEW SHOWROOM. ADDITION OF <br />EXISTING INTERIOR OFFICES TO ACCOMMODATE NEW SALES FLOOR, LOUNGE, SERVICE COUNTER,AND <br />NEW CAR DELIVERY AREA. ADJUSTMENT OF THE SERVICE BUILDINGS TO ACCOMMODATE NEW <br />RESTROOMS.NEW FINISHES THROUGHOUT. REWORK OF SITE TO ACCOMMODATE NEW SHOWROOM <br />AND LANDSCAPE MODIFICATIONS. <br />SEPERATE PERMITS <br />THE FOLLOWING PORTIONS OF THE PROJECT WILL BE APPLIED FOR UNDER SEPARATE PERMITS <br />1. HVAC SYSTEM. (DUCTING, DISTRIBUTION, CONTROLS, AND ASSOCIATED STRUCTURAL) <br />2. LINE VOLTAGE ELECTRICAL SYSTEM WORK. <br />3. LIFE SAFETY SYSTEMS. (HORNS, STROBES &FIRE ALARM/SPRINKLER IMPROVEMENTS) <br />4. LOW VOLTAGE ELECTRICAL SYSTEMS. (TELEPHONE/DATA/SECURITY/INTERCOM) <br />6. PLUMBING (WATER, SANITARY, NATURAL GAS) <br />6. SIGN PACKAGE <br />APPLICABLE CODES <br />NATIONAL: <br />2018 INTERNATIONAL BUILDING CODE W/ WASHINGTON STATE AMENDMENTS (61-60 WAC) <br />2018 INTERNATIONAL EXISTING BUILDING CODE <br />2018 INTERNATIONAL FIRE CODE W/ WASHINGTON STATE AMENDMENTS (61-64 WAC) <br />2018 INTERNATIONAL MECHANICAL CODE W/ WASHINGTON STATE AMENDMENTS (61-62 WAC) <br />2009 ICC A117.1 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES <br />REGIONAL: <br />2018 WASHINGTON STATE EN ERGY CODE (61-11 WAC) <br />2018 WASHINGTON STATE ADMINSTRATIVE CODE (WAC) <br />2018 EVERETT MUNICIPAL CODE <br />VICINITY MAP <br />PRO„��� ���„����. <br />b <br />TS AND SERVICE BUILDING � <br />9 <br />9 <br />SOUTH SERVICE ANEX BUILDING � <br />6 <br />,\ o\ \ <br />SITE PLAN BUILDING DIAGRAM �NI/ <br />PROJECTADDRESS: 7802 EVERGREEN WAY <br />EVERETT. WA 98203 <br />JURISDICTION: <br />SNOHOMISH COUNTY <br />PARCEL NUMBER: <br />28060700300700 <br />ZONING: <br />B <br />OCCUPAN CY CLASSIFICATION: <br />BUSINESS <br />TYPE OF CONSTRUCTION: <br />III-B <br />SPRIN KLERED: <br />YES <br />NUMBER OF STORIES: <br />2 <br />SQ. FT. OF EXISTING PARTS AND SERIVCE <br />PARTS AND SERVICE BUILDING: <br />7,480 <br />SOUTH SERVICE ANNEX BUILDING: <br />9,741 <br />SQ. FT. OF EXISTING SHOWROOM <br />FIRST FLOOR: <br />6,368 <br />SECOND FLOOR: <br />2,288 <br />EXISTING TOTAL: <br />7�66 <br />SQ. FT. OF SHOWROOM IMPROVEMENT <br />FIRST FLOOR: <br />9,848 <br />FIRST FLOOR EXPANSION: <br />4,480 <br />SECOND FLOOR: 2,288 <br />IMPROVEMENT TOTAL: 12�36 <br />ZONING DATA <br />PER EMC B-ZONING REQUIREMENTS <br />LANDSCAPE SETBACKS: <br />STREE FRONTAGE: 2' FRONTAGE, 6' SIDEWALK, 4' LANDSCAPE ZONE SEE SHEET A2.01 <br />SIDES: 6'TYPE III LANDSCAPE BUFFER SEE SH EET A2.01 <br />REAR: 10'TYPEILAN DSCAPE BUFFER SEE SH EET A2.01 <br />PER EMC 19.36.080: <br />4.OUTDOOR STORAGE AREAS AND VEHICLE SALES DO NOT REQUIRE INTERIOR LANDSCAPING <br />STRUCTURE HEIGHT <br />EMC 19.22.020 <br />LANDSCAPE MODIFCIATION <br />REQUIRED LANDSACPING <br />WEST PROPERTY LINE : <br />3,620 SF (10 FT TYPE I BUFFFER) <br />SOUTH PROPERTY LIN E: <br />2,220 SF (6FT TYPE III BU FFER) <br />NORTH PROPERTY LINE: <br />2,220 SF (SFT TYPE III BU FFER) <br />STREET FRONTAGE: <br />1,408 SF (4FT LANDSCAPE/ FURNITURE ZONE) <br />INTERNAL: <br />N/A (CAR SALES AND SERVICE USE) <br />REQUIRED LANDSCAPING: <br />9,368 SF <br />PROVIDED LANDSACPING <br />WEST, SOUTH, <br />NORTH PROPERTY <br />LINES COMBINED : <br />7,686 SF (VARIABLE WITH TYPE I&III BUFFFER) <br />STREET FRONTAGE: <br />3,249 SF (EXISTING AREAS TO BE UPGRADED) <br />INTERNAL: <br />1.162 SF (TYPE III) <br />PROVIDED LANDSCAPING: <br />12.087 SF <br />PARKING CALCULATIONS <br />PER EMC 12.16.030: RETAIL TRADE AND SERVICES, OUTDOOR INCLUDING 1 : 1000 SF <br />(1/1000129.367 = 30 STALLS <br />TOTAL PUBLIC PARKING REQUIRED= 30 STALLS <br />TOTAL PARKING PROVIDED: <br />REGULAR 28 <br />ACCESSIBLE 2 <br />TOTAL 30 PUBLIC STALLS TOTAL <br />REQUIRED PARKING STALLS <br />PER 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN TABLE 208.2: THE TOTAL NUMBER OF PARKING <br />SPACES PROVIDED IS 30� THUS FOR 26-60 STALLS PROVIDED 2 ACCESSIBLE STALLS ARE REQUIRED. <br />REQUIRED BICYCLE PARKING PER BMC 12.16.030: ONE BICYCLE PARKING FOR EVERY 12 REQUIRED MOTOR <br />VEHICLE SPACES, UP TO A MAXIMUM REQUIREMENT OF 20 BICYCLE SPACES. 30 / 12 = 3 BICYCLE PARKING <br />REQUIRED. <br />a <br />U <br />8 <br />FREIHEIT <br />ARCHITECTURE <br />J <br />W <br />0 <br />CO <br />G <br />NW�/ <br />L.I_ <br />W <br />''� <br />VJ <br />0 <br />Z <br />C� <br />G <br />O <br />O } <br />M <br />O z � <br />''2^ w a, <br />VJ <br />0 LLI � <br />z �W W <br />N � <br />LLI <br />� W <br />12738 <br />REGISTERED <br />ARCHITECT <br />j <br />�`� �� <br />MICHAEL J TON <br />STATE OF WASXINGTON <br />ISSUE LIST <br />PERMIT SUBMITTAL 03.31.2022 <br />GENERAL NOTES <br />A0.01 <br />