Laserfiche WebLink
5-Year 101.798 <br /> 10-Year 102.491 <br /> 25-Year 102.929 <br /> 50-Year 103.447 <br /> 100-Year 103.907 <br /> ***********Groundwater Recharge Summary************* <br /> Recharge is computed as input to Perind Groundwater Plus Infiltration in Structures <br /> Total Predeveloped Recharge During Simulation <br /> Model Element Recharge Amount (ac-ft) <br /> Subbasin: Subbasin 1 206.988 <br /> Total: 206.988 <br /> Total Post Developed Recharge During Simulation <br /> Model Element Recharge Amount (ac-ft) <br /> Subbasin: Subbasin 1 36.686 <br /> Link: New Structure Lnk1 462.901 <br /> Total: 499.587 <br /> Total Predevelopment Recharge is Less than Post Developed <br /> Average Recharge Per Year, (Number of Years= 158) <br /> Predeveloped: 1.310 ac-ft/year, Post Developed: 3.162 ac-ft/year <br /> ***********Water Quality Facility Data************* <br /> SCENARIO: PREDEVELOPED <br /> Number of Links: 0 <br /> SCENARIO: POSTDEVELOPED <br /> Number of Links: 1 <br /> ********** Link: New Structure Lnk1 ********** <br /> Basic Wet Pond Volume (91% Exceedance): 4293. cu-ft <br /> Computed Large Wet Pond Volume, 1.5*Basic Volume: 6440. cu-ft <br /> 2-Year Discharge Rate : 0.000 cfs <br /> 15-Minute Timestep, Water Quality Treatment Design Discharge <br /> On-line Design Discharge Rate (91% Exceedance): 0.13 cfs <br /> Off-line Design Discharge Rate (91% Exceedance): 0.07 cfs <br /> Time to Infiltrate 91%Treatment Volume, (Hours): 60.75 <br />