Laserfiche WebLink
VERETT <br />0 <br />Permit Number: P2310-038 <br />Applied: 10/25/2023 <br />Issued: 2/12/2024 <br />Status: FINALED <br />Parent Permit: B2309-071 <br />Parent Project: <br />Details <br />Permit Inspections <br />City of Everett <br />Approved:2/7/2024 <br />Fi n a I ed : 8/1/2024 <br />Description: COMMERCIAL KITCHEN --Plumbing Permit <br />Site Address: 8417 EVERGREEN WAY STE 3 <br />City, State Zip Code: EVERETT, WA 98208-2613 <br />Applicant: Nos Narin <br />Owner: CFT NV DEVELOPMENTS LLC <br />Contractor: STEVE'S PLUMBING LLC <br />SCHEDULED DATE <br />COMPLETED DATE <br />TYPE <br />INSPECTOR <br />RESULT <br />REMARKS <br />4/2/2024 <br />4/2/2024 <br />PLUMB 03-ROUGH <br />JASON <br />CORRECTION <br />see notes <br />IN <br />MORRISSEY <br />REQUIRED <br />Notes: <br />Multiple Code Corrections, list is not exhaustive:- Multiple drains are severely back graded. Slope all drains to 2% per UPC chap 7 as well as vents per <br />chap 9.- Multiple dry vents are back -graded and rolled below centerline of drains. Roll all vents below flood level above drain centerline per chap 9 <br />UPC.- Missing vents for fixtures.- Non code horizontal wet vents. Wet vents are for bathroom group fixtures only per UPC chap 9.- Espresso dump and <br />mop sink need to drain to grease line per plans.- Install floor sink for indirect drainage from three compartment sink.- Run relief drains for back -flow <br />devices separately to floor sink with appropriate air gaps.- Insulate all hot lines per WSEC.- Remove redundant p traps under slab. Cannot double trap <br />fixtures per chap 10 UPC. Cannot have union traps in concealed locations. <br />4/10/2024 <br />4/10/2024 <br />PLUMB 03-ROUGH <br />JASON <br />CORRECTION <br />see notes <br />IN <br />MORRISSEY <br />REQUIRED <br />Notes: <br />STEVE'S PLUMBING LLC CONTRACTOR <br />Address 2125 196TH ST SW, #126 LYNNWOOD, WA 98036 License 49361 <br />Phone (425)774-0483 Email STEVESPLUMBING@COMCAST.NET <br />- Multiple drains are still extremely back graded with flow draining the wrong direction. Slope all drains to 2% slope or 1/4" drop per linear foot. Per UPC <br />708.1- Replace medium sweep and vent 90's on vents below flood level with approved long sweep fittings per UPC 905.1, 905.2, 905.3.- Non code wet <br />vent for bathroom toilets. If circuit venting must be done to code otherwise vent toilets separately and tie vents together 6" above flood rim of toilets <br />per UPC chap 9.- Recirc pump will be required in order to get hot water to hand washing fixtures fast enough. Dedicated loop and pump.- Make sure all <br />under slab DWV is visible for inspection. Ok to bed underneath and to centerline of pipe.- Mechanical permit is still not issued." Lisr is not exhaustive. <br />4/18/2024 <br />4/18/2024 <br />PLUMB 03-ROUGH <br />JASON <br />NOT READY <br />see notes <br />IN <br />MORRISSEY <br />Notes: <br />360-567-9442 <br />- Previous corrections still incomplete. <br />PLUMB 02- <br />4/22/2024 <br />4/22/2024 <br />GROUND <br />JASON <br />CORRECTION <br />see notes <br />WORK/SLAB <br />MORRISSEY <br />REQUIRED <br />Notes: <br />360-567-9442 <br />jjm changed Inspection Type from PLUMB 03-ROUGH IN to PLUMB 02-GROUND WORK/SLAB <br />- Set grade on grease and sanitary common drains to 2% minimum slope per UPC 708.1 (owner has marked three spots that are less than 2% slope) - <br />One floor sink vent needs to be rolled above centerline of drain per UPC 905.2. <br />�A_ <br />Printed: Tuesday, 29 April, 2025 1 of 2 rk <br />SUPERION <br />