Laserfiche WebLink
13 of 34 <br /> 1■■III..TI <br /> Hilti PROFIS Engineering 3.0.75 <br /> www.hilti.com <br /> Company: Otak,Inc. Page: 3 <br /> Address: Specifier: <br /> Phone I Fax: E-Mail: <br /> Design: BRT Shelter Windscreen Retrofit-Short Direction Date: 2/3/2022 <br /> Fastening point: <br /> 3.1 Steel Strength <br /> Nsa =ESR value refer to ICC-ES ESR-3187 <br /> Nsa ?Na. ACI 318-14 Table 17.3.1.1 <br /> Variables <br /> .1 <br /> Ase,N[in z] fut.[psi] <br /> 0.14 58,000 <br /> Calculations <br /> Nsa[lb] <br /> 8,230 <br /> Results <br /> Nsa[lb] •steel 4t Nsa[lb] N.[lb] <br /> 8,230 0.750 6,172 1,792 <br /> Input data and results must be checked for conformity with the existing conditions and for plausibility! <br /> PROFIS Engineering(c)2003-2022 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan <br /> �5/Q0 3 <br />