My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8410 EVERGREEN WAY SWIFT 2025-07-21
>
Address Records
>
EVERGREEN WAY
>
8410
>
SWIFT
>
8410 EVERGREEN WAY SWIFT 2025-07-21
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/21/2025 3:51:29 PM
Creation date
4/29/2025 2:07:36 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
8410
Tenant Name
SWIFT
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2 of 34 <br /> 114111�T1 <br /> Hilti PROFIS Engineering 3.0.75 <br /> www.hilti.com <br /> Company: Otak,Inc. Page: 2 <br /> Address: Specifier: <br /> Phone I Fax: I E-Mail: <br /> Design: BRT Shelter Windscreen Retrofit-Long Direction Date: 2/3/2022 <br /> Fastening point: <br /> 1.1 Design results <br /> Case Description Forces[Ib]/Moments[ft.lb] Seismic Max.Util.Anchor[%] <br /> 1 Long Direction N=0;V5=0;Vy=314; no 31 <br /> M5=-1,125.000;My=0.000;Mz=0.000; <br /> Ns„s=0;M0,sus=0.000;My Sus=0.000; <br /> 2 Load case/Resulting anchor forces v <br /> • <br /> ( npressiK 4 <br /> Anchor reactions[Ib] <br /> Tension force:(+Tension,-Compression) <br /> Anchor Tension force Shear force Shear force x Shear force y <br /> 1 872 78 0 78 <br /> 2 872 78 0 78 - <br /> 3 0 78 0 78 <br /> 4 0 78 0 78 <br /> max.concrete compressive strain: 0.08[%e] <br /> max.concrete compressive stress: 339[psi] 1 • 2 <br /> resulting tension force in(x/y)=(-0.000/-3.500): 1,745[Ib] <br /> resulting compression force in(x/y)=(0.000/4.238): 1,745[Ib] Tension <br /> Anchor forces are calculated based on the assumption of a rigid anchor plate. <br /> 3 Tension load <br /> Load N.[Ib] Capacity• Nn[Ib] Utilization PN=Nua/4) Nn Status <br /> Steel Strength* 872 6,172 15 OK <br /> Bond Strength" 1,745 5,697 31 OK <br /> Sustained Tension Load Bond Strength* N/A N/A N/A N/A <br /> Concrete Breakout Failure" 1,745 6,756 26 OK <br /> *highest loaded anchor "'anchor group(anchors in tension) <br /> Input data and results must be checked for conformity with the existing conditions and for plausibility! <br /> PROFIS Engineering(c)2003-2022 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan <br /> 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.