Laserfiche WebLink
5 of 34 <br /> 141111.1119 <br /> Hilti PROFIS Engineering 3.0.75 <br /> www.hilti.com <br /> Company: Otak,Inc. Page: 5 <br /> Address: Specifier: <br /> Phone I Fax: I E-Mail: <br /> Design: BRT Shelter Windscreen Retrofit-Long Direction Date: 2/3/2022 <br /> Fastening point: <br /> 3.3 Concrete Breakout Failure <br /> Ncbg = (ANco) w ec,N Wed,N wc,N t1cp,N Nb ACI 318-14 Eq.(17.4.2.1 b) <br /> Ncbg >Nua ACI 318-14 Table 17.3.1.1 <br /> ANc see ACI 318-14,Section 17.4.2.1,Fig.R 17.4.2.1(b) <br /> ANco =9 hef ACI 318-14 Eq.(17.4.2.1c) <br /> 1 <br /> WecN = (1 +2eN/ <1.0 ACI 318-14 Eq.(17.4.2.4) <br /> 3 het <br /> ed,N =0.7+0.3 cmin <1.0 ACI 318-14 Eq.(17.4.2.5b) <br /> 1.5her <br /> yr cp N =MAX(Ca=min 1.5het) <1.0 ACI 318-14 Eq.(17.4.2.7b) <br /> cac C.c <br /> Nb =kc X.a ei het ACI 318-14 Eq.(17.4.2.2a) <br /> Variables <br /> het[in.] ec1.N[in.] ecz N[in.] ca,min[in.] W c,N <br /> 4.000 0.000 0.000 1.000 <br /> Cac[in.] kc k a tc[psi] <br /> 10.058 17 1.000 4,000 <br /> Calculations <br /> ANc[in.2] ANcg[in.2] W ec1,N Vec2,N wed,N Wcp,N Nb[Ib] <br /> 174.00 144.00 1.000 1.000 1.000 1.000 8,601 <br /> Results <br /> Ncbg[Ib] 41 concrete Ncbg[Ib] Nee[lb] <br /> 10,393 0.650 6,756 1,745 <br /> Input data and results must be checked for conformity with the existing conditions and for plausibility! <br /> PROFIS Engineering(c)2003-2022 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan <br /> 5 <br /> /:)<-) <br />