Laserfiche WebLink
4 of 34 <br /> NI`TI <br /> Hilti PROFIS Engineering 3.0.75 <br /> www.hilti.com <br /> Company: Otak, Inc. Page: 4 <br /> Address: Specifier: <br /> Phone I Fax: E-Mail: <br /> Design: BRT Shelter Windscreen Retrofit-Long Direction Date: 2/3/2022 <br /> Fastening point: <br /> 3.2 Bond Strength <br /> Nag = (AN.0) q�ect,Na Wec2,Na Wed,Na Wcp,Na Nba ACI 318-14 Eq.(17.4.5.1b) <br /> Nag >Nua ACI 318-14 Table 17.3.1.1 <br /> ANa see ACI 318-14,Section 17.4.5.1,Fig.R 17.4.5.1(b) <br /> ANao =(2 CNa)2 ACI 318-14 Eq.(17.4.5.1c) <br /> cNa =10 de V T1 uncr100 ACI 318-14 Eq.(17.4.5.1d) <br /> 1 <br /> Wcc,Na = (1 + eN) <1.0 ACI 318-14 Eq.(17.4.5.3) <br /> CNa <br /> ed,Na =0.7+0.3(Ca=min) <1.0 ACI 318-14 Eq.(17.4.5.4b) <br /> CNa <br /> W cp,Na =MAX(c=min CNa) <1.0 ACI 318-14 Eq.(17.4.5.5b) <br /> cac cac <br /> Nba = e• Tkc'R•de• he, ACI 318-14 Eq.(17.4.5.2) <br /> Variables <br /> k,c,uncr[psi] da[in.] het[in.] cairn[in•] aoverhead Tk,c[psi] <br /> 2,327 0.500 4.000 1.000 1,190 <br /> ec,,N[in.] ec2.N[in.] cac[in.] A a <br /> 0.000 0.000 10.058 1.000 <br /> Calculations 1 1 <br /> cNa[in.] ANa[In•2] ANaa[In•2] th ed,Na <br /> 7.239 245.82 209.62 1.000 <br /> ec1,Na Wec2,Na Wcp,Na Nba[lb] <br /> 1.000 1.000 1.000 7,475 <br /> Results <br /> Nee[lb] bond • Nag[lb] N [lb] <br /> 8,765 0.650 5,697 1,745 <br /> Input data and results must be checked for conformity with the existing conditions and for plausibility! <br /> PROFIS Engineering(c)2003-2022 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan <br /> 4 <br />