Laserfiche WebLink
4 of 34 <br /> 1■■11`II.T1 <br /> Hilti PROFIS Engineering 3.0.75 <br /> www.hilti.com <br /> Company: Otak, Inc. Page: 4 <br /> Address: Specifier: <br /> Phone I Fax: I E-Mail: <br /> Design: BRT Shelter Windscreen Retrofit-Long Direction Date: 2/3/2022 <br /> Fastening point: <br /> 3.2 Bond Strength <br /> = W\ANa/ . . . <br /> Nag ec1,Na Wec2,Na �ed,Na �cp,Na Nba ACI318-14Eq.(17451b) <br /> ANaO <br /> 0 Nag >N. ACI 318-14 Table 17.3.1.1 <br /> ANa see ACI 318-14,Section 17.4.5.1,Fig.R 17.4.5.1(b) <br /> ANaO =(2 CNa)2 ACI 318-14 Eq.(17.4.5.1c) <br /> CNa =10 da uncr <br /> 1 ACI 318-14 Eq.(17.4.5.1d) <br /> 100 <br /> 1 <br /> wec.Na = \, + eN <1.0 ACI 318-14 Eq.(17.4.5.3) <br /> CNa <br /> ed,Na =0.7+0.3(Cam—'") <1.0 ACI 318-14 Eq.(17.4.5.4b) <br /> / CNa <br /> W cp,Na =MAX Cam"—'I" a) <1.0 ACI 318-14 Eq.(17.4.5.5b) <br /> ` Cac Cac <br /> Nba =X •tk,c'n'de•het ACI 318-14 Eq.(17.4.5.2) <br /> Variables <br /> k,c,uncr[psi] da[in.] hef[in.] Ca,wn[In.] aooenhead rk,c[psi] <br /> 2,327 0.500 4.000 1.000 1,190 <br /> ec1,N[in.] eC2,N[in.] Cac[in.] a <br /> 0.000 0.000 10.058 1.000 <br /> Calculations <br /> CNa[in.] ANa[in.2] ANa0[in 2] W ed,Na <br /> 7.239 245.82 209.62 1.000 <br /> ec1,Na Wec2,Na Wcp,Na Nba[lb] <br /> 1.000 1.000 1.000 7,475 <br /> Results <br /> Nag[lb] 4)bond + Nag[lb] N.[lb] <br /> 8,765 0.650 5,697 1,745 <br /> Input data and results must be checked for conformity with the existing conditions and for plausibility! <br /> PROFIS Engineering(c)2003-2022 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan <br /> 4 <br />