Laserfiche WebLink
• <br /> 12 of 34 <br /> 1■■11`T1 <br /> Hilti PROFIS Engineering 3.0.75 <br /> www.hilti.com <br /> Company: Otak,Inc. Page: 2 <br /> Address: Specifier: <br /> Phone I Fax: I E-Mail: <br /> Design: BRT Shelter Windscreen Retrofit-Short Direction Date: 2/3/2022 <br /> Fastening point: <br /> 1.1 Design results <br /> Case Description Forces[lb]/Moments[ft.lb] Seismic Max.Util.Anchor[%] <br /> 1 Short Direction N=0;V,=265;Vy=0; no 51 <br /> M,=0.000;My=-949.500;Mz=0.000; <br /> Nsus=0;Mx,su5=0.000;My 5 5=0.000; <br /> 2 Load case/Resulting anchor forces •y <br /> 03 O4 <br /> Anchor reactions[lb] <br /> Tension force:(+Tension,-Compression) <br /> Anchor Tension force Shear force Shear force x Shear force y <br /> 1 14 66 66 0 <br /> 2 1,792 66 66 0 <br /> 3 14 66 66 0 Corn 3ression Tension <br /> 4 1,792 66 66 0 <br /> max.concrete compressive strain: 0.17[%o] <br /> max.concrete compressive stress: 737[psi] <br /> resulting tension force in(x/y)=(1.231/0.000): 3,613[lb] 0 1 0 2 <br /> resulting compression force in(x/y)=(-1.923/0.000):3,613[lb] <br /> Anchor forces are calculated based on the assumption of a rigid anchor plate. <br /> 3 Tension load <br /> Load Nua[lb] Capacity• Nn[lb] Utilization P5=Ned/ Nn Status <br /> Steel Strength* 1,792 6,172 30 OK <br /> Bond Strength** 3,613 7,224 51 OK <br /> Sustained Tension Load Bond Strength* N/A N/A N/A N/A <br /> Concrete Breakout Failure** 3,613 8,876 41 OK <br /> *highest loaded anchor **anchor group(anchors in tension) <br /> Input data and results must be checked for conformity with the existing conditions and for plausibility! <br /> PROFIS Engineering(c)2003-2022 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan <br /> 2 <br />