Laserfiche WebLink
14 of 34 <br /> I�■�II.TI <br /> Hilti PROFIS Engineering 3.0.75 <br /> www.hilti.com <br /> Company: Otak,Inc. Page: 4 <br /> Address: Specifier: <br /> Phone I Fax: I E-Mail: <br /> Design: BRT Shelter Windscreen Retrofit-Short Direction Date: 2/3/2022 <br /> Fastening point: <br /> 3.2 Bond Strength <br /> A <br /> Nag = (Na/ W ec1,Na Wec2,Na Wed,Na Wcp,Na Nba ACI 318-14 Eq.(17.4.5.1b) <br /> Na <br /> Nag >Nua ACI 318-14 Table 17.3.1.1 <br /> ANa see ACI 318-14,Section 17.4.5.1,Fig.R 17.4.5.1(b) <br /> ANao =(2 cNa)2 ACI 318-14 Eq.(17.4.5.1c) <br /> cNa =10 da -JT ncr ACI 318-14 Eq.(17.4.5.1d) <br /> 1100 <br /> 1 <br /> Wec,Na = \1 eN <1.0 ACI 318-14 Eq.(17.4.5.3) <br /> cNa <br /> W ed,Na =0.7+0.3 (ca,min) <1.0 ACI 318-14 Eq.(17.4.5.4b) <br /> cNa <br /> W cp,Na =MAX(ca=min cNa) <1.0 ACI 318-14 Eq.(17.4.5.5b) <br /> cac cac <br /> Nba = a•tk,c•a•da•hat ACI 318-14 Eq.(17.4.5.2) <br /> Variables k,c,uncr[psi] dB[in.] he[In.] ca,min[in.] <br /> aoverhead tkc[psi] <br /> 2,327 0.500 4.000 1.000 1,190 <br /> ec1.N[in] ec2,N[in.] cac[in.] X a <br /> 1.231 0.000 10.058 1.000 <br /> Calculations <br /> cNa[in.] ANa[in.2] ANao[in.2] W ed,Na <br /> 7.239 364.67 209.62 1.000 <br /> ec1,Na Wec2,Na Wcp,Na Nba[lb] <br /> 0.855 1.000 1.000 7,475 <br /> Results <br /> Nag[lb] 4)bond Nag[lb] Nua[lb] <br /> 11,114 0.650 7,224 3,613 <br /> Input data and results must be checked for conformity with the existing conditions and for plausibility! <br /> PROFIS Engineering(c)2003-2022 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan <br /> 4 <br /> �6 as <br />