Laserfiche WebLink
5 of 34 <br /> 1■■1111 ilT1 <br /> Hilti PROFIS Engineering 3.0.75 <br /> www.hilti.com <br /> Company: Otak,Inc. Page: 5 <br /> Address: Specifier: <br /> Phone I Fax: I E-Mail: <br /> Design: BRT Shelter Windscreen Retrofit-Long Direction Date: 2/3/2022 <br /> Fastening point: <br /> 3.3 Concrete Breakout Failure <br /> Ncbg =(ANc W ec,N Wed,N Wc,N Wcp,N Nb ACI 318-14 Eq.(17.4.2.1b) <br /> ANao <br /> 4) Ncbg>Nua ACI 318-14 Table 17.3.1.1 <br /> ANC see ACI 318-14,Section 17.4.2.1,Fig.R 17.4.2.1(b) <br /> ANco =9 hef ACI 318-14 Eq.(17.4.2.1c) <br /> 1 <br /> W ec,N = 2 eN <1.0 ACI 318-14 Eq.(17.4.2.4) <br /> 1 +3hef <br /> • <br /> ed,N =0.7+0.3 (ca, <br /> 1.5mh!n) <1.0 ACI 318-14 Eq.(17.4.2.5b) <br /> et <br /> cpN =MAX( 'a' 1.5hefl <1.0 ACI 318-14 Eq.(17.4.2.7b) <br /> ` c�a--c Cac <br /> Nb =kc a A fc hef5 ACI 318-14 Eq.(17.4.2.2a) <br /> Variables <br /> het[in.] ec1,N[in.] ea N[in.] ca,min[in.] W c,N <br /> 4.000 0.000 0.000 1.000 <br /> cac[in.] kc A a fa[psi] <br /> 10.058 17 1.000 4,000 <br /> Calculations) <br /> ANc[In 2] ANcO[in•2] W ecl,N Wec2,N Wed,N Wcp,N Nb[Ib] <br /> 174.00 144.00 1.000 1.000 1.000 1.000 8,601 <br /> Results <br /> Ncbg[lb] 4t concrete NcbO[Ib] Nua[Ib] <br /> 10,393 0.650 6,756 1,745 <br /> Input data and results must be checked for conformity with the existing conditions and for plausibility! <br /> PROFIS Engineering(c)2003-2022 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan <br /> 5 <br />