15 of 34 <br /> M11619111.I <br /> Hilti PROFIS Engineering 3.0.75 <br /> www.hilti.com <br /> Company: Otak,Inc. Page: 5 <br /> Address: Specifier: <br /> Phone I Fax: I E-Mail: <br /> Design: BRT Shelter Windscreen Retrofit-Short Direction Date: 2/3/2022 <br /> Fastening point: <br /> 3.3 Concrete Breakout Failure <br /> Ncbg A <br /> (ANc) W ec,N Wed,N Wc,N Wcp,N Nb ACI 318-14 Eq. (17.4.2.1 b) <br /> NcO <br /> 4) Ncbg>N ACI 318-14 Table 17.3.1.1 <br /> ANc see ACI 318-14,Section 17.4.2.1,Fig.R 17.4.2.1(b) <br /> ANco =9 he} ACI 318-14 Eq.(17.4.2.1c) <br /> 1 <br /> WecN = \1+2_e'N <1.0 ACI 318-14 Eq.(17.4.2.4) <br /> 3 haf <br /> WedN =0.7+0.3 ca,min <10 <br /> 1.5her ACI318-14 Eq.(17.4.2.5b) <br /> W cpN =MAX(ca=min 1-5her` <1.0 ACI 318-14 Eq.(17.4.2.7b) <br /> crac cac <br /> Nb =kc A.a Vfc hats ACI 318-14 Eq. (17.4.2.2a) <br /> Variables <br /> hat[in.] ecI.N[in.] ec2 N[in.] c [in.] W c,N <br /> a,min <br /> 4.000 1.231 0.000 ^c 1.000 <br /> cac[in.] kc A.a tc[psi] <br /> 10.058 17 1.000 4,000 <br /> Calculations <br /> ANc[in.2] Artao[in.2] W ec1.N Wec2,N Wed,N Wcp,N Nb[Ib] <br /> 275.50 144.00 0.830 1.000 1.000 1.000 8,601 <br /> Results <br /> Ncbg[lb] 4)concrete 4) Ncbg[Ib] Nua[lb] <br /> 13,656 0.650 8,876 3,613 <br /> Input data and results must be checked for conformity with the existing conditions and for plausibility! <br /> PROFIS Engineering(c)2003-2022 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan <br /> 5 <br /> 6?- g <br />