Laserfiche WebLink
5 of 34 <br /> 1�1`TI <br /> Hilti PROFIS Engineering 3.0.75 <br /> www.hilti.com <br /> Company: Otak,Inc. Page: 5 <br /> Address: Specifier: <br /> Phone I Fax: E-Mail: <br /> Design: BRT Shelter Windscreen Retrofit-Long Direction Date: 2/3/2022 <br /> Fastening point: <br /> 3.3 Concrete Breakout Failure <br /> Ncbg = (A p) W ec,N Wed,N Wc,N Wcp.N Nb ACI 318-14 Eq.(17.4.2.1b) <br /> Ncbg >Nua ACI 318-14 Table 17.3.1.1 <br /> AN, see ACI 318-14,Section 17.4.2.1,Fig.R 17.4.2.1(b) <br /> AN, =9 het ACI 318-14 Eq.(17.4.2.1c) <br /> 1 <br /> Wec.N — �1 +2eN) <1.0 ACI 318-14 Eq.(17.4.2.4) <br /> 3 het <br /> tf ed N =0.7+0.3 (Ca.5mhinet) 1.0 ACI 318-14 Eq.(17.4.2.5b) <br /> of cp,N =MAX(C=min 1.`Jhef) <1.0 ACI 318-14 Eq.(17.4.2.7b) <br /> Cac Cac <br /> Nb =kc 1,a Air c hers ACI 318-14 Eq.(17.4.2.2a) <br /> Variables <br /> het[in.] ec1,N[in.] ec2N[[in.] Cans[in.] c.N <br /> 4.000 0.000 0.000 1.000 <br /> Cac[in.] kc A a tc[psi] <br /> 10.058 17 1.000 4,000 <br /> Calculations <br /> ANc[in.2] ANcO[in.2] W ecl,N Wec2,N Wed,N Wcp.N Nb[Ib] <br /> 174.00 144.00 1.000 1.000 1.000 1.000 8,601 <br /> Results <br /> Ncbg[Ib] t concrete • Ncbg[Ib] Nua[Ib] <br /> 10,393 0.650 6,756 1,745 <br /> Input data and results must be checked for conformity with the existing conditions and for plausibility! <br /> PROFIS Engineering(c)2003-2022 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan <br /> 5 <br />