Laserfiche WebLink
7 of 34 <br /> Hilti PROFIS Engineering 3.0.75 <br /> www.hilti.com <br /> Company: Otak,Inc. Page: 7 <br /> Address: Specifier: <br /> Phone I Fax: I E-Mail: <br /> Design: BRT Shelter Windscreen Retrofit-Long Direction Date: 2/3/2022 <br /> Fastening point: <br /> 4.2 Pryout Strength(Bond Strength controls) <br /> Vcpg =kcp[(A ANao"a) t�ec1 Na Wec2,Na Wed,Na Wcp,Na Nba ] ACI 318-14 Eq.(17.5.3.1b) <br /> Vcpg >Vua ACI 318-14 Table 17.3.1.1 <br /> ANa see ACI 318-14,Section 17.4.5.1,Fig.R 17.4.5.1(b) <br /> ANao =(2 CNa)2 ACI 318-14 Eq.(17.4.5.1c) <br /> CNa =10 da V uncr ACI 318-14 Eq.(17.4.5.1d) <br /> 1100 <br /> 1 <br /> ec,Na = \1 + eN I <1.0 ACI 318-14 Eq.(17.4.5.3) <br /> CNa <br /> ed,Na =0.7+0.3 (Ca'n) <1.0 ACI 318-14 Eq.(17.4.5.4b) <br /> CNa <br /> Wp,N ca =MAX(Cin=m CNa) <1.0 ACI 318-14 Eq.(17.4.5.5b) <br /> cac Cac <br /> Nba =X • tk,c 'L da'het ACI 318-14 Eq.(17.4.5.2) <br /> Variables <br /> kcp a'overhead tk,c,uncr[psi] da[in.] het[in.] Ca,min[in.] t k,c[psi] <br /> 2 1.000 2,327 0.500 4.000 1,190 <br /> ec,N[in.] ecz,N[in.] cac[in.] A a <br /> 0.000 0.000 10.058 1.000 <br /> Calculations <br /> CNa[in.] ANa[in.2] ANao[in.2] W ed,Na <br /> 7.239 364.67 209.62 1.000 <br /> W ec1,Na Wec2,Na Wcp,Na Nba[lb] <br /> 1.000 1.000 1.000 7,475 <br /> Results <br /> V [lb]_ cp9 concrete 4t V [lb] V.[lb] <br /> _ PA. ua <br /> 26,006 0.700 18,204 314 <br /> 5 Combined tension and shear loads <br /> (3N RV Utilization[1NY[%] Status <br /> R 0.306� 0.024 5/3 15 OK <br /> PNV—IIN+nV<=1 <br /> Input data and results must be checked for conformity with the existing conditions and for plausibility! <br /> PROFIS Engineering(c)2003-2022 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan <br /> 7 <br />