Laserfiche WebLink
14 of 34 <br /> I0III6.TI <br /> Hilti PROFIS Engineering 3.0.75 <br /> www.hilti.com <br /> Company: Otak,Inc. Page: 4 <br /> Address: Specifier: <br /> Phone I Fax: I E-Mail: <br /> Design: BRT Shelter Windscreen Retrofit-Short Direction Date: 2/3/2022 <br /> Fastening point: <br /> 3.2 Bond Strength <br /> =(A <br /> ANa) W N ACI 318-14 Eq. 17.4.5.1b <br /> Nag ec1,Na Wec2,Na Wed,Na Wcp,Na ba ( ) <br /> NaO <br /> Nag >N a ACI 318-14 Table 17.3.1.1 <br /> AN. see ACI 318-14,Section 17.4.5.1,Fig.R 17.4.5.1(b) <br /> Aria()`ria0 =(2 CNa)2 ACI 318-14 Eq.(17.4.5.1c) <br /> , I1100 <br /> cNa =10 da V ACI 318-14 Eq.(17.4.5.1d) <br /> 1 <br /> VesNa = \1 + eN <1.0 ACI 318-14 Eq.(17.4.5.3) <br /> CNa <br /> W ed,Na =0.7+0.3 (ci 1 0 ACI 318-14 Eq.(17.4.5.4b) <br /> —Na <br /> cp,Na =MAX(ca,min cNa) 1.0 ACI 318-14 Eq.(17.4.5.5b) <br /> cac ca. <br /> Nba =a•a•tk,c•It•da•her ACI 318-14 Eq.(17.4.5.2) <br /> Variables <br /> k,c,uncr[psi] da[in.] her[in.] Gamin[in.] aoverhead tk a[psi] <br /> 2,327 0.500 4.000 1.000 1,190 <br /> ec1,N[in.] ecz N[in.] cae[in.] a <br /> 1.231 0.000 10.058 1.000 <br /> Calculations <br /> cNa[in.] AN.[in.2] ANao[in.2] W ed,Na <br /> 7.239 364.67 209.62 1.000 <br /> _ w ec1,Na Wec2,Na Wcp,Na Nba[lb] <br /> 0.855 1.000 1.000 7,475 <br /> Results <br /> Nag[Ib] 4)bond 4) Nag[Ib] N.[Ib] <br /> 11,114 0.650 7,224 3,613 <br /> Input data and results must be checked for conformity with the existing conditions and for plausibility! <br /> PROFIS Engineering(c)2003-2022 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan <br /> 4 <br />