Laserfiche WebLink
7 of 34 <br /> MULTI <br /> Hilti PROFIS Engineering 3.0.75 <br /> www.hilti.com <br /> Company: Otak,Inc. Page: 7 <br /> Address: Specifier: <br /> Phone I Fax: E-Mail: <br /> Design: BRT Shelter Windscreen Retrofit-Long Direction Date: 2/3/2022 <br /> Fastening point: <br /> 4.2 Pryout Strength(Bond Strength controls) <br /> [(ANa) W N ] ACI 318-14 E17.5.3.1b VcP9 _kcp ANaO ec1,Na Wec2,Na Wed,Na Wcp,Na ba ( ) <br /> 4) Vcpg >V. ACI 318-14 Table 17.3.1.1 <br /> ANa see ACI 318-14,Section 17.4.5.1,Fig.R 17.4.5.1(b) <br /> ANa, =(2 CNa)2 ACI 318-14 Eq.(17.4.5.1c) <br /> cNa =10 da V 1100 ACI 318-14 Eq.(17.4.5.1d) <br /> 1 <br /> Wec,Na = (1 <br /> eN/ <1.0 ACI 318-14 Eq.(17.4.5.3) <br /> CNa <br /> W ed,Na =0.7+0.3( "inc <br /> <1.0 ACI 318-14 Eq.(17.4.5.4b) <br /> W cp,Na =MAX(Ca,min, Ca CNJa) <1.0 ACI 318-14 Eq.(17.4.5.5b) <br /> Cac <br /> Nba =X a•Tk,c•tc.da•het ACI 318-14 Eq.(17.4.5.2) <br /> Variables <br /> kcp aoverhead Tk,c,uncr[psi] da[in.] het[in.] Ca,min[in.] T k,c[psi] <br /> 2 1.000 2,327 0.500 4.000 oe 1,190 <br /> ec1,N[in.] eaN[in.] cap[in.] X a <br /> 0.000 0.000 10.058 1.000 <br /> Calculations <br /> CNa[in.] ANa[in 2] ANa0[in•2] W ed,Na <br /> 7.239 364.67 209.62 1.000 <br /> ec1,Na Wec2,Na Wcp,Na Nba[Ib] <br /> 1.000 1.000 1.000 7,475 <br /> Results <br /> Vcpq[Ib] 4,concrete (I) Vcpq[Ib] Vua[lb] <br /> 26,006 0.700 18,204 314 <br /> 5 Combined tension and shear loads <br /> PN PV Utilization PN,V[%] Status <br /> 0.306 0.024 5/3 15 OK <br /> PNv=PN+Pv<=1 <br /> Input data and results must be checked for conformity with the existing conditions and for plausibility) <br /> PROFIS Engineering(c)2003-2022 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan <br />