My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3700 FEDERAL AVE PORTABLE 6 JACKSON ELEMENTARY 2025-08-07
>
Address Records
>
FEDERAL AVE
>
3700
>
JACKSON ELEMENTARY
>
3700 FEDERAL AVE PORTABLE 6 JACKSON ELEMENTARY 2025-08-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/7/2025 2:30:29 PM
Creation date
5/1/2025 3:02:07 PM
Metadata
Fields
Template:
Address Document
Street Name
FEDERAL AVE
Street Number
3700
Unit
PORTABLE 6
Tenant Name
JACKSON ELEMENTARY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
161
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
_FAJACOBSON <br /> .' CONSULTING ENGINEENN <br /> Table 2.0: Existing Land Cover Conditions <br /> Tributary Impervious Grass Field with <br /> Discharge Area (sf) Pervious Area Sub-Drain (sf) Total Area(sf) <br /> Location <br /> Combined 98,956 39,405 24,685 163,504 <br /> Sewer <br /> Offsite Wetland 30,376 20,361 10,515 57,352 <br /> Total 125,890 59,766 35,200 220,856 <br /> The proposed project includes the relocation of 4 portable classrooms with the addition of 3 <br /> more portables to the school. The total area of land disturbance is 11,061 square feet. This <br /> includes the area land that the portable classrooms on the school campus get relocated from <br /> (existing underlaying asphalt pavement to remain). <br /> Table 3.0: Proposed Land Cover Conditions <br /> Tributary Impervious Grass Field with <br /> Discharge Area (sf) Pervious Area Sub-Drain (sf) Total Area (sf) <br /> Location <br /> Combined 104,300 39,405 19,341 163,504 <br /> Sewer <br /> Offsite Wetland 32,428 20,361 8,463 57,352 <br /> Total 125,890 59,766 35,200 220,856 <br /> The total area of converted grass field with under drain to impervious area associated with the <br /> portable classrooms and associated walkways is 7,396 square feet. Of the total area of <br /> converted grass area with under-drain: 2,052 square feet is within the sub-basin that discharges <br /> to the existing wetland south of the school and 5,344 square feet are in the sub-basin that <br /> discharges to the combined sewer in Federal Avenue. <br /> Section 2 - Conditions and Requirements Summary <br /> The combined requirements of City of Everett Stormwater Management Manual and the <br /> Washington State Department of Ecology's Stormwater Management Manual for Western <br /> Washington (current edition) will apply to all new and redevelopment projects and activities <br /> within the City of Everett unless one of the following applies: The project site is legally served by <br /> a combined storm and sanitary sewer system, in which case the stormwater standards shall be as <br /> set in Section 6-10 of the City of Everett Design and Construction Standards and Specifications. <br /> This project meets that criteria and therefore information required by City of Everetts Standards <br /> Section 6-10 is provided below. <br /> 255 S.King Street,Suite 800,Seattle,WA 98104 I 206.426.2600 I JACOBSONENGINEERS.COM <br />
The URL can be used to link to this page
Your browser does not support the video tag.