Laserfiche WebLink
Dimensions Field Configuration <br /> G4 Notification Appliances Temporal horn and horn-strobe models are factory set to sound in <br /> 1 62" a three-pulse temporal pattern. By sliding the tone selector switch, <br /> (4.11 cm) 4.95" horn only models may be configured for constant horn output that <br /> (12.57 cm) can be coded at precise intervals by EDWARDS control panels and <br /> control modules. <br /> 0°o 0 o°0000 o0o000000000 Note:Temporal 3 coding is the required output for fire notification <br /> 0°o°o°O0g- 0 0000000°°°0 <br /> o.....000000011 00 0000000000000° ° devices per NFPA 72.Any device coding other than temporal <br /> °° 000000 Ooo000000000 3 is at the discretion and approval of the local authority having <br /> ° °omo°000 00O°O°o <br /> ); 000000 <br /> 0.0 <br /> 0 0 0 00°00000 �000°ooa 0 0 0 jurisdiction(AHJ). <br /> ° °000*00M1 000000oo0o00 <br /> 1 0°0°0°0°0°°0° °00000000.0.o Horns and horn-strobes are factory set for high dB output. Low <br /> ® 1 °°°°°0 o00000 0000°0 0°0 0°° 5.78„ dB output may be selected b sliding the tone selector switch. <br /> 't °° °0°o0oe9 Ego°0°0°° (14.68cm) p Y Y g <br /> °0°000°0°°°0° 00000000°0 0 This reduces the output by about 6 dBA. <br /> °0 0 0 0 0 0 0 0° <br /> Genesis LED clear strobes and horn-strobes may be set for 15, <br /> 30, 75, or 110 candela output.The output setting is changed by <br /> simply removing the cover and sliding the candela switch to the <br /> desired setting.The device does not have to be removed from <br /> the wall to change the output setting.The setting remains visible <br /> through a small window on the left-hand side of the device after <br /> the cover is closed. <br /> G4T Trim Plate(optional) Light and Sound Output Settings <br /> 0.3" <br /> (0.76 cm) 5.6" <br /> (14.22 cm) <br /> O O O <br /> 7.5" <br /> (19.05 cm) (5) <br /> /(6)— �ec-HroH //3) <br /> 1 )— T-LOW l ) <br /> (�0 O O O 0 n (8)— �T-HIGH <br /> (1)Constant,low dB (5)110 candela <br /> (2)Constant,high dB (6)75 candela <br /> (3)T3 temporal,low dB (7)30 candela <br /> (4)T3 temporal,high dB (8)15 candela <br /> Diagnostics <br /> Operating current <br /> Horns Strobes <br /> Sound 16 to 33 16 to 33 Strobe 16 to 33 16 to 33 <br /> setting VDC VFWR setting VDC VFWR <br /> C-Low, 15,30, <br /> 18 mA 22 mA 28 mA 36 mA <br /> 0 o O T--Low 75, 110 <br /> C-High, 28 mA 38 mA <br /> T-High <br /> ® Horn-Strobes <br /> Strobe <br /> setting Sound setting 16 to 33 VDC 16 to 33 VFWR <br /> 15,30, C-Low,T-Low 40 mA 48 mA <br /> Test points indicated above are used to validate the 75, 110 C-High,T-High 50 mA 65 mA <br /> Notification Appliance Circuit and verify device function. <br /> Page 3 of 6 DATA SHEET E85001-0668 <br /> Not to be used for installation purposes. Issue 1.2 <br />