916 PACIFIC AVE 2ND FLOOR 2025-06-30
>
Address Records
>
PACIFIC AVE
>
916
>
2ND FLOOR
>
916 PACIFIC AVE 2ND FLOOR 2025-06-30
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2025 1:39:19 PM
Creation date
5/2/2025 1:34:44 PM
Metadata
Fields
Template:
Address Document
Street Name
PACIFIC AVE
Street Number
916
Tenant Name
2ND FLOOR
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
97
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
/I\ <br />ROOM FINISH SCHEDULE <br />ROOM NO. <br />ROOM NAME <br />WALLS <br />CEILING <br />REMARKS <br />FLOOR <br />BASE <br />NORTH <br />SOUTH <br />EAST <br />WEST <br />WAINSCOT <br />MATERIAL <br />FINISH <br />MATERIAL <br />FINISH <br />MATERIAL <br />FINISH <br />MATERIAL <br />FINISH <br />MATERIAL <br />FINISH <br />MATERIAL <br />FINISH <br />MATERIAL <br />FINISH <br />MATERIAL <br />FINISH <br />HEIGHT <br />201 <br />WAITING <br />VINYL TILE <br />_VT -I <br />RUBBER <br />RB-I <br />PAINT <br />P-1 <br />PAINT <br />P-1 <br />PAINT <br />P-1 <br />PAINT <br />P-2 <br />-- <br />-- <br />ACT <br />ACT -I <br />V-0" <br />-- <br />202 <br />RECEPT <br />VINYL TILE <br />LVT-1 <br />RUBBER <br />R5-1 <br />PAINT <br />P-I <br />PAINT <br />P-1 <br />PAINT <br />P-I <br />PAINT <br />P-I <br />-- <br />-- <br />ACT <br />ACT-1 <br />W-O" <br />-- <br />203 <br />OFFICE <br />VINYL TILE <br />LVT-I <br />RUBBER <br />RB-I <br />PAINT <br />P-I <br />PAINT <br />P-I <br />PAINT <br />P-2 <br />PAINT <br />P-1 <br />-- <br />-- <br />ACT <br />ACT -I <br />V-0" <br />-- <br />204 <br />WORK <br />VINYL TILE <br />LVT-1 <br />RUBBER <br />RB-I <br />PAINT <br />P-1 <br />PAINT <br />P-1 <br />PAINT <br />P-1 <br />PAINT <br />P-1 <br />-- <br />-- <br />ACT <br />ACT-1 <br />W-0" <br />-- <br />205 <br />HALL <br />VINYL TILE <br />LVT-I <br />RUBBER <br />RB-I <br />PAINT <br />P-I <br />PAINT <br />P-I <br />PAINT <br />P-I <br />PAINT <br />P-I <br />-- <br />-- <br />ACT <br />ACT-1 <br />V-0" <br />-- <br />206 <br />ADA RESTROOM <br />S.VINYL <br />SV-1 <br />COVE <br />SV-I <br />PAINT <br />P-I <br />PAINT <br />P-1 <br />PAINT <br />P-I <br />PAINT <br />P-1 <br />-- <br />-- <br />-- <br />P-1 <br />W-0" <br />-- <br />207 <br />CLOSET <br />VINYL TILE <br />LVT-I <br />RUBBER <br />RB-I <br />PAINT <br />P-I <br />PAINT <br />P-I <br />PAINT <br />P-I <br />PAINT <br />P-I <br />-- <br />-- <br />ACT <br />ACT-1 <br />W-O" <br />-- <br />200 <br />NOURISHMENT AREA <br />VINYL TILE <br />LVT-1 <br />RUBBER <br />RB-I <br />PAINT <br />P-I <br />PAINT <br />P-I <br />PAINT <br />P-I <br />PAINT <br />P-I <br />-- <br />-- <br />ACT <br />ACT -I <br />W-0" <br />-- <br />209 <br />CONSULT <br />VINYL TILE <br />LVT-I <br />RUBBER <br />RB-I <br />PAINT <br />P-2 <br />PAINT <br />P-I <br />PAINT <br />P-I <br />PAINT <br />P-I <br />-- <br />-- <br />ACT <br />ACT-1 <br />W-O" <br />-- <br />210 <br />CONSULT <br />VINYL TILE <br />LVT-1 <br />RUBBER <br />RB-I <br />PAINT <br />P-I <br />PAINT <br />P-2 <br />PAINT <br />P-I <br />PAINT <br />P-I <br />-- <br />-- <br />ACT <br />ACT-1 <br />W-0" <br />-- <br />211 <br />CONSULT <br />VINYL TILE <br />LVT-I <br />RUBBER <br />RB-I <br />PAINT <br />P-1 <br />PAINT <br />P-2 <br />PAINT <br />P-1 <br />PAINT <br />P-1 <br />-- <br />-- <br />ACT <br />ACT -I <br />V-0" <br />-- <br />212 <br />OFFICE <br />VINYL TILE <br />LVT-1 <br />RUBBER <br />RB-I <br />PAINT <br />P-2 <br />PAINT <br />P-I <br />PAINT <br />P-I <br />PAINT <br />P-I <br />-- <br />-- <br />ACT <br />ACT -I <br />W-0" <br />-- <br />213 <br />BREAK <br />VINYL TILE <br />LVT-I <br />RUBBER <br />RB-I <br />PAINT <br />P-1 <br />PAINT <br />P-1 <br />PAINT <br />P-1 <br />PAINT <br />P-1 <br />-- <br />-- <br />ACT <br />ACT -I <br />V-0" <br />-- <br />214 <br />GROUP THERAPY <br />VINYL TILE <br />_VT -I <br />RUBBER <br />RB-I <br />PAINT <br />P-11FAIRNTP-1 <br />PAINT <br />P-1 <br />PAIq�F-l <br />-- <br />-- <br />ACT <br />ACT -I <br />W-O" <br />-- <br />215 <br />SUPPLIES <br />VINYL TILE <br />_VT -I <br />RUBBER <br />RB-I <br />-- <br />-- <br />PAINT <br />P-1 <br />PAI <br />-- <br />-- <br />ACT <br />ACT -I <br />V-0" <br />-- <br />216 <br />ACTIVITY <br />VINYL TILE <br />_VT -I <br />RUBBER <br />RB-I <br />PAINT <br />P-I <br />PAINT <br />P-1 <br />PAI <br />-- <br />-- <br />ACT <br />ACT-1 <br />W-O"218 <br />PATIENT TOILET <br />S.VINYL <br />SV-1 <br />COVE <br />SV-1 <br />PAINT <br />P-1 <br />PAINT <br />P-1 <br />PAI <br />-- <br />-- <br />GAB <br />P-1 <br />e'-0" <br />-- <br />DOOR AND FRAME SCHEDULE <br />DOOR <br />FRAME <br />FIRE <br />RATING <br />LABEL <br />HARDWARE <br />GROUP <br />REMARKS <br />MARK <br />SIZE <br />ELEVATION <br />MATERIAL <br />MATERIAL <br />DETAIL <br />WIDTH <br />HEIGHT <br />THICKNESS <br />HEAD <br />JAMB <br />SILL <br />205A <br />V-O" <br />7'-0" <br />1 5/4" <br />F <br />AD <br />HM <br />4 <br />4 <br />-- <br />-- 2 <br />-- 6 <br />206A <br />V-0" <br />7'-0" <br />1 3/4" <br />F <br />WD <br />HIM <br />4 <br />4 <br />-- <br />-- <br />214A <br />V-O" <br />T-0" <br />1 3/4" <br />N <br />WD <br />HM <br />4 <br />4 <br />-- <br />-- <br />1 <br />-- <br />216A <br />V-O" <br />7'-0" <br />1 3/4" <br />F <br />AD <br />HM <br />4 <br />4 <br />-- <br />-- <br />6 <br />-- <br />213A <br />V-O" <br />7'-0" <br />1 3/4" <br />-- <br />AD <br />EXIST. <br />-- <br />-- <br />-- <br />-- <br />4 <br />MODIFY EXISTING HDWR <br />2135 <br />3'-0" <br />7'-W <br />1 3/4" <br />-- <br />AD <br />EXIST. <br />-- <br />-- <br />-- <br />-- <br />4 <br />MODIFY EXISTING HDWR <br />2148 <br />1 3-0 <br />1 7'-0" <br />1 3/4" <br />N <br />WD <br />EXIST. <br />-- <br />-- <br />-- <br />-- <br />5 <br />MODIFY EXISTING DOOR <br />216A <br />V-O" <br />7'-0" <br />1 3/4" <br />-- <br />AD <br />EXIST. <br />-- <br />-- <br />-- <br />-- <br />4 <br />MODIFY EXISTING HDWR <br />2165 <br />V-O" <br />7'-0" <br />1 3/4" <br />-- <br />AD <br />EXIST. <br />-- <br />-- <br />-- <br />-- <br />4 <br />MODIFY EXISTING HOAR <br />HANGERS TO BE #12 GA GAILY <br />SOFT -ANNEALED MILD STEEL WIRE <br />AT 4'-0"OC AND MAX 8" FROM END <br />WALLS - ATTACHED W/ MIN (3)TURNS <br />TO <br />CEILING SUSPENSION MEMBERS <br />AND TO Y4" x 3" LAG INTO BOT EDGE <br />OF <br />ROOF JOIST. WHERE WIRES ARE <br />SPLAYED <br />MORE THAN I IN 6 OUT OF PLUMB, <br />PROVIDE COUNTER SLOPING WIRES <br />UNISTRUT METAL STUD <br />OR STEEL L COMPRESSION \ f� <br />STRUT AT ALL SPLAY WIRE <br />#6 STSM <br />MAIN <br />LATERAL FORCE BRACINGE-4 NO. 12-GA WIRES, <br />SPLAYED AT 90• FROM EACH OTHER. <br />SLOPED AT A MAX. OF 45• FROM THE PLANE <br />OF THE CEILING, CONNECTED TO MAIN RUNNERS <br />WITHIN 2" OF INTERSECTIONS WITH CROSS <br />RUNNERS <br />AND LOCATED A MAXIMUM OF 12'-0" <br />IN BOTH DIRECTIONS AND <br />A MAXIMUM OF 6'-0" FROM EACH WALL. <br />45• - Ez <br />(TYP) (/ <br />VERIFY <br />EXIST. WIDT <br />METAL STUD FRAMING <br />PAINTABLE CAULK AS <br />REQUIRED TO FILL GAPS <br />1/2" 1/ " <br />HOLLOW METAL DOOR FRAME <br />(PAINT) <br />F � <br />0 <br />SILENCER AS SPECIFIED <br />N <br />DOOR AS SCHEDULED <br />ARIE <br />1 1/4 1 15/16" <br />HEAD (JAMB SIM.) - HM FRAME <br />3. , 1.-0. <br />25 GA. BRACING ALTERNATING <br />. SECURED TO TOP OF WALL <br />JCTURE ABOVE W/ 3/8" CIA. <br />dCHOR <br />'E PER PLAN <br />0 <br />(4) TIGHT TURNS (TYP) POWER DRIVEN FASTENERS ® 24" O.C. <br />O CROSS TEE <br />FINISH FLOOR PER PLAN <br />2" (MAX) <br />TYP FOR ALL <br />BRACE WIRES <br />6" (MAX) <br />CEILING SEISMIC BRACE DETAIL WALL SECTION AND BRACING DETAIL <br />l 1 1/2' . T-O 2 1 1/2' 1'-0 <br />NEW ACT NEW ACT <br />CLG. CLG, <br />EXIST. SOFFIT EXISTING SOFFIT <br />7'-3" <br />5/6" GAB EA. SIDE <br />OVER 3 5/8 METAL <br />STUDS 0 16" OC All <br />SOUND INSUL. <br />(VERIFY MATCH W/ <br />EXIST. SOFFIT) <br />NEW WALL/SOFFIT DETAIL <br />3 <br />0 <br />EXIST. WALL 6" MIN. <br />ABOVE CEILING <br />5/8" TYPE 'X' GYP. BOARD <br />TYP. EACH SIDE <br />3-5/8" METAL STUDS <br />AT 16" O.C. <br />WiUSE WATER RESISTANT <br />GYP. BD. IN MOISTURE <br />PRONE AREAS <br />3-5/8' METAL STUDS <br />1.. 1.-0. <br />NOTE: <br />• WHERE EXISTING DOOR 214E 15 NOTED IN 'REMARKS' TO BE MODIFIED, NEW NARROW LITE <br />PER DOOR TYPE 'N' 15 TO BE CUT IN. EXISTING DOOR FRAME TO REMAIN. <br />• NEW DOORS ARE TO RECEIVE STAIN TO MATCH EXISTING DOORS. <br />• NEW AND EXIST. HM DOOR FRAMES TO BE PAINTED. <br />DOOR TYPES <br />6"b" b"6n <br />6 6 <br />m m <br />fY (Y <br />NEW CUT <br />IN 1/4" - SAFETY <br />SAFETY GL. <br />GL. <br />F N N <br />EXISTING NEW <br />DOOR DOOR <br />DOOR <br />HARDWARE GROUPS <br />GROUP <br />#I <br />GROUP #3 <br />GROUP #6 <br />3 EA. <br />HINGES <br />3 EA. HINGES <br />3 EA. HINGES <br />I EA. <br />PASSAGE SET <br />I EA. LOCKSET <br />I EA. PRIVACY LOCKSET All <br />3 EA. <br />SILENCERS <br />3 EA. SILENCERS <br />OCCUPANCY INDICATOR <br />I EA. <br />CLOSER <br />I EA. WALL STOP <br />3 EA. SILENCERS <br />I EA. <br />WALL STOP <br />I EA, WALL STOP <br />GROUP #4 <br />1 EA. KEYPAD LOCK/LEVER <br />GROUP <br />tt2 <br />(REPLACE EXIST. <br />NDWR) <br />3 EA. <br />HINGES <br />I EA. <br />PASSAGE SET <br />GROUP #5 <br />3 EA. <br />SILENCERS <br />I EA. PASSAGE SET <br />I EA. <br />CLOSER <br />(REPLACE EXIST. <br />NDWR) <br />I EA. <br />HOLD OPEN <br />I EA. <br />WALL STOP <br />INTERIOR FINISH SPECIFICATIONS <br />SYMBOL <br />ITEM <br />MANUFACTURER <br />NOTES <br />P-I <br />PAINT <br />MFG: BENJAMIN MOORE REGAL SELECT <br />COLOR: DOVE WING (OC-18) <br />FINISH: EGGSHELL <br />GENERAL <br />COLOR <br />P-2 <br />PAINT <br />MFG: BENJAMIN MOORE REGAL SELECT <br />COLOR: KENTUCKY HAZE (AC-16) <br />FINISH: EGGSHELL <br />ACCENT WALL <br />COLOR <br />R5-1 <br />RUBBER <br />BASE <br />MFG: ROPPE <br />COLOR: DOLPHIN 129 <br />6" BASE <br />SS-1 <br />SOLID <br />SURFACE <br />MFG: CORIAN <br />COLOR: RAIN CLOUD <br />COUNTERTOP <br />B SPLASH <br />PL-I <br />PLASTIC <br />LAMINATE <br />MFG: WILSONART <br />COLOR: MONGOLIA LENO WEAVE 5012K-19 <br />CASEWORK <br />FACE <br />LVT-I <br />LUXURY <br />VINYL TILE <br />MFG: ARMSTRONG <br />COLOR: SAVANNA MONSOON SOME <br />LUXURY <br />VINYL <br />TILE <br />5V-I <br />SHEET <br />VINYL <br />MFG TARKETT <br />COLOR: TO BE SELECTED <br />SEAMLESS <br />SHEET <br />VINYL <br />ACT-1 <br />CEILING <br />MFG: ARMSTRONG #1729 FINE FISSURED <br />COLOR: WHITE <br />SIZE: 24" X 24" <br />ACOUSTICAL <br />TILE <br />CEILING <br />CG-I <br />CORNER <br />GUARD <br />MFG: INPRO <br />SIZE: I" WING, 46"H <br />MOUNT AT TOP OF RUB. BASE <br />STAINLESS <br />STEEL <br />AP-1 <br />FRL WALL <br />PROTECTION <br />MFG: PANOLAM <br />COLOR: TO BE SELECTED <br />STYLE TO BE SELECTED <br />WAINSCOT <br />5/8" TYPE 'X' GYP. BOARD <br />TYP. EACH SIDE <br />SOUND ATENUATION <br />BATTS TO FILL WALL <br />CAVITY <br />3-5/8" METAL STUDS <br />AT 16" O.C. <br />USE WATER RESISTANT <br />GYP. BD. IN MOISTURE <br />PRONE AREAS <br />C3-5/8' METAL STUDS <br />1. , T-o.ZLL <br />5/8" TYPE 'X' GYP. BOARD <br />SOUND ATENUATION <br />BATTS TO FILL WALL <br />CAVITY <br />CHASE INTERIOR ROOM <br />METAL STUDS <br />AT 16" O.C. <br />USE WATER RESISTANT <br />GYP. BD. IN MOISTURE <br />PRONE AREAS <br />3-1/2' METAL STUDS <br />�o <br />x <br />2727 Oakes Ave. <br />Suite 100 <br />Everett. WA 98201 <br />AEVISIONS <br />A DON REVISION II/19/24 <br />an REGISTERED <br />ARCHITECT <br />STATE OF WASHINGTON <br />p <br />W <br />C0 <br />`V O` <br />CO <br />/a) =^^`` <br />V MW <br />c W <br />W I <br />O O <br />n0 0 <br />li <br />IoB la. 24-1008 <br />ow,wN er "Z <br />C—ED ar DS <br />PERMIT SET <br />8-22-2024 <br />SCHEDULES <br />&•k <br />L City of Everett Permit Services <br />EVERETT Reviewed for Permit 01/14/2025 <br />