My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
916 PACIFIC AVE 2ND FLOOR 2025-06-30
>
Address Records
>
PACIFIC AVE
>
916
>
2ND FLOOR
>
916 PACIFIC AVE 2ND FLOOR 2025-06-30
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2025 1:39:19 PM
Creation date
5/2/2025 1:34:44 PM
Metadata
Fields
Template:
Address Document
Street Name
PACIFIC AVE
Street Number
916
Tenant Name
2ND FLOOR
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
97
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LOAD RATED R SHALL R SHALL <br />FASTENERS EQUAL OR _ � EQUAL OR <br />HANGER STRAPS OR RODS R SHALL BE GREATER 2� 1/3W GREATER <br />BE <br />BAND SAME EQUAL OR <br />MAX. BE THAN 1/3W. VANE THAN 1/6W. <br />SIZE AS MAX. DUCT 0 QUANTITY SIZE MAX. LOAD SPACING P <br />HANGER STRAP-..\ IN. [mm] IN. [mm] LOS. [kg] IN. [mm] THAN <br />TAR VANE <br />1/6W <br />O 26 650 ONE 1 25 z 22 GA STRAP 260 119 144 3600 ,p � <br />36 [9001 ONE 1 r251 z 18 GA STRAP 420 F1901 144 3600 <br />50 r12501 ONE 1 F251 z 16 GA STRAP 700 F3171 144[36001 AV <br />50" DIAMETER OR 60 15001 TWO 3 8 [1010. RODS 1320 [5981 144 3600 W <br />LESS 84 [21001 TWO 1 2 13 0 RODS 2500 r11331 144 136001�--� <br />HANGER RODS <br />BAND <br />OVER 50" DIAMETER <br />NOTES: <br />1. TABULATED DATA FROM SMACNA ALLOWS FOR <br />DUCT REINFORCING AND INSULATION, BUT NO <br />EXTERNAL LOAD <br />ROUND DUCT HANGER DETAIL <br />M3.1 SCALE: NONE <br />TRUNK DUCT <br />AIRFLOW <br />CONICAL SPIN -IN <br />LAR <br />(MIN. 2" GER) <br />DIFFUSER OR GRILLE <br />(TYP). REFER TO <br />ACCEPTABLE CONNECTION <br />DETAILS <br />NOT LESS THAN ONE ' <br />STRAP HANGER FOR <br />EACH FLEX DUCT <br />NOTE: <br />1. DO NOT USE FLEXIBLE DUCT IF NOT INDICATED ON <br />PLANS. PROVIDE SHEETMETAL DUCT, RECTANGULAR IF <br />NEEDED FOR SPACE CONSTRAINTS. <br />(3) ACCEPTABLE ROUND <br />DUCT TAKE -OFFS <br />PROVIDE A VOLUME DAMPER <br />FOR EVERY DIFFUSER AND <br />GRILLE. LOCATE DAMPER AS <br />FAR AS PRACTICAL, AND <br />WITH NOT LESS THAN 6 <br />LINEAR FEET OF DUCT, <br />FROM DIFFUSER OR GRILLE. <br />LOCATE DAMPERS ON <br />RECORD DRAWINGS AND <br />COORDINATE WITH AIR <br />BALANCER <br />STANDARD RADIUS <br />OR LONG RADIUS <br />ELBOW <br />SHORT RADIUS <br />ELBOW WITH ONE <br />VANE <br />NOTES: <br />1. THE INTERIOR SURFACE OF ALL RADIUS ELBOWS SHALL BE MADE ROUND <br />2. ALL STANDARD RADIUS ELBOWS CAN BE SUBSTITUTED WITH SHORT RADIUS <br />ELBOWS. ALL SHORT RADIUS ELBOWS SHALL HAVE VANES. VANES SHALL BE <br />CONSTRUCTED, SUPPORTED AND FASTENED AS RECOMMENDED BY SMACNA. <br />MDUCT RADIUS ELBOWS <br />M3.1 SCALE: NONE <br />FLEXIBLE DOT SEE / <br />PLANS OR DIFFUSER F <br />SCHEDULE FOR SIZES. <br />SEE SPECIFICATIONS <br />FOR MAXIMUM LENGTHS PLAN <br />PROVIDE 1/4" BEAD PERFORATED PLATE OR <br />AROUND COLLAR FOR EXPANDED METAL 64% <br />CLAMP CATCH FREE AREA ---, <br />4 FOOT MINIMUM, 6 FOOT <br />MAXIMUM LENGTH AND 139 <br />MAX MUM CUMULATIVE <br />CHANGE OF DIRECTION FOR <br />FLEX DUCT. PROVIDE AT <br />LEAST 90' CHANGE OF <br />DIRECTION WHERE POSSIBLE <br />FOR ACOUSTICAL <br />CONSIDERATION. NO HARD tl <br />CORNERS OR TURNS LESS <br />THAN 1.5 RADIUS. SMACNA APPROVED CLAMP <br />ok NOTE: ELEVATION <br />FLEXIBLE DUCT TO DIFFUSERS SHALL NOT BE USED ABOVE <br />NON -REMOVABLE HARD CEILINGS. USE RIGID DUCT CONNECTIONS. <br />APPLICABLE FOR LAB AND OFFICE SPACES ONLY. <br />CONNECTING DUCT FOR <br />3 DIFFUSERS AND GRILLES DETAIL <br />M3.1 SCALE: NTS <br />SHORT RADIUS <br />ELBOW WITH TWO <br />VANES <br />DIFFUSER NECK SIZE <br />1/2 DIFFUSER NECK <br />SIZE ALL SIDES <br />SQUARE OR ROUND <br />DIFFUSER NECK. <br />DIFFUSER BOOT W/ <br />ACOUSTIC LINING <br />DIFFUSER BOOT W/ <br />1' ACOUSTIC LINING <br />DIMENSION TO SUIT <br />CEILING PLENUM. <br />MINIMUM TO BE DUCT <br />CONNECTION SIZE +2". <br />4 DIFFUSER CONNECTION DETAIL <br />lllf� <br />SCALE: NTS <br />0 <br />(n <br />O 11 <br />Z <br />rn <br />t V <br />U N <br />N <br />O i <br />m Q <br />Z. <br />�z <br />LL�a <br />;.; <br />Vz <br />2727 Oakes Ave. <br />Suite 100 <br />Everett, WA 98201 <br />REVISIONS <br />A DOH REVISION 12/11/24 <br />D <br />WASgf CT'� <br />FT <br />IgyA1, tt>f'14�'1�" <br />12/12/24 <br />z� <br />OQ <br />U Lv <br />,LIJ = <br />V / <br />U Q <br />LL O <br />U <br />nQ Q <br />LIJ W <br />U m <br />LIJ <br />> O <br />O <br />n� O <br />I__L LL <br />NI 242095 <br />I— CEI <br />ON <br />PERMIT SET <br />08/22/24 <br />MECHANICAL <br />DETAILS <br />J <br />M3.1 <br />City of Everett Permit Services <br />EVERETT Reviewed for Permit 01/14/2025 <br />
The URL can be used to link to this page
Your browser does not support the video tag.