Laserfiche WebLink
SPECIFICATIONS: <br />1. THE GENERAL, SUPPLEMENTARY AND OTHER CONDITIONS OF THE CONTRACT, <br />MODIFICATIONS TO THE GENERAL CONDITIONS, THE DRAWINGS, AND THE APPLICABLE <br />PROVISIONS OF THE OTHER DIVISIONS ARE HEREBY MADE A PART OF THIS DIVISION AND <br />ALL ITS SECTIONS. <br />2. THE REQUIREMENTS OF THIS SECTION APPLY TO ALL ELECTRICAL WORK. <br />3. COORDINATE ELECTRICAL WORK WITH RELATED WORK SHOWN AND SPECIFIED <br />ELSEWHERE. <br />4. WORK INCLUDED: THE CONTRACTOR SHALL PERFORM ALL THE WORK REQUIRED <br />(INCLUDING THE FURNISHING OF ALL SUPERVISION, LABOR, SERVICES, TOOLS, MATERIALS <br />AND EQUIPMENTAND THE PERFORMANCE OF ALL OPERATIONS AND INCIDENTALS <br />NECESSARY) FORA COMPLETE, SAFE AND RELIABLE ELECTRICAL INSTALLATION, <br />ADJUSTED, TESTED AND READY FOR OPERATION. THE ELECTRICAL WORK (NEW AND <br />MODIFICATION OF EXISTING) IS GENERALLY DESCRIBED AS FOLLOWS: <br />A. DEMOLITION. <br />B. GROUNDING. <br />C. WIRING DEVICES AND SPECIAL PURPOSE RECEPTACLES. <br />D. ANCILLARY SYSTEMS RACEWAYS, BOXES, ETC. <br />E. LIGHTING FIXTURES. <br />F. LIGHTING CONTROLS AND DEVICES. <br />G. BRANCH CIRCUIT WIRING SYSTEM FOR LIGHTING, OUTLETS, EQUIPMENT, ETC. <br />H. MODIFICATION & EXPANSION TO THE EXISTING FIRE DETECTION AND ALARM. <br />I. SUPPORTS. <br />J. PULL STRINGS AND ROPES. <br />K. TEMPORARY CONSTRUCTION POWER AND LIGHTING. <br />F. TESTING AND COMPLETING. <br />M. OBTAINING AND PAYING FOR ALL REQUIRED LICENSES, PERMITS, INSPECTIONS AND <br />FEES. <br />5. WORK NOT INCLUDED: THE FOLLOWING ELECTRICAL SYSTEM RELATED WORK WILL BE <br />PROVIDED BY THE OWNER, GENERAL CONTRACTOR, OR OTHER SUBCONTRACTORS WORKI <br />DIRECTLY WITH THE OWNER: <br />A. MECHANICAL CONTRACTOR: MECHANICAL EQUIPMENT AND SYSTEMS LOW VOLTAGE <br />CONTROL WIRING, CONDUITS, DEVICES, ETC. SEE MECHANICAL SPECIFICATION <br />SECTIONS AND SCHEDULE ON DRAWINGS. <br />B. TELECOMMUNICATIONS WIRING SYSTEM. <br />C. VIDEO SURVEILLANCE CAMERAS & WIRING. <br />6. EXISTING CONDITIONS: BEFORE SUBMITTING BID, EXAMINE EXISTING SITE AND <br />EQUIPMENT CONDITIONS TO DETERMINE EFFECT ON EXECUTION OF THE ELECTRICAL <br />WORK AND INCLUDE COSTS IN BID. <br />7. THE CONTRACTOR SHALL COORDINATE THE WORK AND COOPERATE WITH THE OWNER, <br />OTHER TRADES, AND SYSTEM CONTRACTORS TO HAVE THE WORK COMPLETED TO THE <br />BEST ADVANTAGE, INSURE THERE ARE NO INTERFERENCES, PROVIDE REASONABLE <br />OPPORTUNITY FOR THE OTHER TRADES AND CONTRACTORS TO COMPLETE THEIR WORK <br />AND TO NOT DELAY THE WORK. <br />8. WORK UNDER THIS PROJECT WILL BE UNDERTAKEN WITH THE FACILITY IN FULL OPERATION <br />9. CONTRACTOR SHALL COORDINATE WORK TO AVOID DISTURBANCE TO BUILDING <br />OPERATIONS AND PERSONNEL, AND TO ALLOW ACCESS FOR BOTH PERSON TO AND <br />WITHIN ALL PORTIONS OF THE FACILITY AND VEHICLES TO THE FACILITY. ACCESS TO <br />OFFICE SPACES, CLASSROOMS, ETC. WILL NOT BE ALLOWED WHEN THEY ARE OCCUPIED. <br />ANY AND ALL COSTS INCURRED FOR NON-STANDARD HOURS, DOUBLE SHIFTS, OVERTIME, <br />ETC. OR ANY OTHER COSTS ASSOCIATED WITH COMPLETING THE PROJECT WITHIN THE <br />COMPLETION TIMES REQUIRED SHALL BE INCLUDED WITHOUT INCREASE IN CONTRACT <br />SUM. <br />10. THE COMPLETED INSTALLATION SHALL BE DONE IN A NEAT & WORKMANLIKE MANNER, <br />SHALL BE SUITABLE FOR THE LOCATION, AND SHALL BE IN ACCORDANCE ALL LAWS, <br />RULES & REGULATIONS IN EFFECT AT THE SITE (INCLUDING THE LATEST EDITIONS OF <br />THE NATIONAL ELECTRICAL CODE (NEC), THE WASHINGTON STATE ELECTRICAL SAFETY <br />STANDARDS, ADMINISTRATION AND INSTALLATION CODE (WAG 296A6B) <br />AND THE WASHINGTON STATE ENERGY CODE). <br />11. CONTRACTORS ARE RESPONSIBLE FOR DETERMINING THE FIRE RESISTIVE RATINGS <br />FOR WALLS, PARTITIONS AND OTHER BUILDING STRUCTURES. INSTALLATION OF <br />NEW SYSTEM COMPONENTS MUST MAINTAIN THE EXISTING FIRE RESISTIVE <br />RATING OF THE PENETRATED BUILDING ELEMENT. <br />12. ALL SYSTEMS, EQUIPMENT, DEVICES, RACEWAYS, CABLES, ETC. INDICATED ARE <br />NEW UNLESS NOTED OTHERWISE. <br />13. ALL ELECTRICAL MATERIALS SHALL BE "UL" (UNDERWRITER'S LABORATORIES, INC.) <br />LISTED, LABELED AND APPROVED FOR THE SERVICE INTENDED WHERE UL STANDARDS <br />HAVE BEEN ESTABLISHED. ALL ELECTRICAL MATERIAL SHALL BE NEW UNLESS <br />SPECIFICALLY NOTED OTHERWISE. <br />14. ALL OPERATIONS SHALL BE CONDUCTED IN A MANNER TO AVOID THE RISK OF HARM TO <br />PERSONS OR DAMAGE TO PROPERTY. DAMAGE SHALL IMMEDIATELY BE REPAIRED. <br />CONSTRUCTION EQUIPMENT& TOOLS SHALL BE IN GOOD OPERATING CONDITION, AND <br />BE DESIGNED FOR THE WORK REQUIRED. VERIFY WITH STRUCTURAL ENGINEER <br />ACCEPTABLE LOCATIONS FOR CORE DRILLING FLOORS, WALLS, ETC. FOR CONDUIT <br />ROUTING. <br />15. POWER INTERRUPTIONS (WHETHER TO THE ENTIRE SYSTEM OR TO INDIVIDUAL <br />BUILDINGS, PANELS, EQUIPMENT, DEVICES, ETC.) SHALL BE KEPT TO AN ABSOLUTE <br />MINIMUM, AND SHALL NOT BE DONE WITHOUT PRIOR APPROVAL, 2 WEEKS <br />ADVANCED SCHEDULING & COORDINATION MEETING WITH THE OWNER. SECONDARY <br />VERIFICATION THAT POWER INTERRUPTION WILL OCCUR IS ALSO REQUIRED 48 HOURS <br />PRIOR TO THE DATE OF OCCURRENCE. THIS ALSO APPLIES TO GENERATOR & ATS <br />TESTING WITH BUILDING LOADS. <br />16. CABLE, BOXES, ETC. SHALL BE STORED OFF THE GROUND, PROTECTED FROM THE <br />WEATHER IN RACKS OR BINS, OR ON SHELVES. EQUIPMENT, WIRING DEVICES, CIRCUIT <br />BREAKERS, ETC. SHALL BE STORED INDOORS IN A DRY, WARM AREA; FREE OF DUST& <br />ONE IN WHICH CONDENSATION WILL NOT OCCUR. <br />17. EQUIPMENT, BOXES, ETC. SHALL BE INSTALLED PLUMB & TRUE, AND BE FIRMLY <br />SUPPORTED EITHER DIRECTLY OR INDIRECTLY BY A SOUND & SAFE STRUCTURAL <br />MEMBER. <br />18. ROUTING OF EXISTING CONDUITS INDICATED IS APPROXIMATE ONLY. <br />19. VERIFY ALL EQUIPMENT, DEVICE, ETC. LOCATIONS WITH THE OWNER PRIOR TO <br />ROUGH -IN. <br />20. DEFINITIONS <br />A. THE TERM "CONTRACTOR" USED THROUGHOUT THESE SPECIFICATIONS AND ON <br />THE ELECTRICAL DRAWINGS SHALL BE UNDERSTOOD TO MEAN THE ELECTRICAL <br />CONTRACTOR. ALL OTHER WORK SHALL BE CALLED OUT BY NAME. <br />B. "FURNISH" MEANS TO SUPPLY AND DELIVER TO THE PROJECT, READY FOR <br />INSTALLATION AND IN OPERABLE CONDITION. <br />C. "INSTALL" MEANS TO INCORPORATE IN THE WORK FINAL POSITION, COMPLETE, <br />ANCHORED, CONNECTED, AND IN OPERABLE CONDITION. <br />D. "PROVIDE" MEANS FURNISH AND INSTALL. <br />E. F.O.I.C. - FURNISHED BY OTHERS, INSTALLED BY CONTRACTOR. <br />21. SUBMITTALS <br />A. PROVIDE SUBMITTALS TO THE ENGINEER, TOGETHER, ATONE TIME, SEPARATED AND <br />INDEXED FOR EACH SPECIFICATION SECTION. INDIVIDUAL OR INCOMPLETE <br />SUBMITTALS ARE NOT ACCEPTABLE. <br />B. THE ENGINEER WILL REVIEW EACH SUBMITTAL, INDICATE ACTION TO BE TAKEN, <br />AND RETURN. THE CONTRACTOR SHALL ALLOW FOR 1 1/2 WEEKS FOR ENGINEER <br />REVIEW MINIMUM. COMPLIANCE WITH SPECIFIED CHARACTERISTICS IS THE <br />CONTRACTOR'S RESPONSIBILITY. APPROVAL OF SUBMITTALS DOES NOT RELEASE <br />THE CONTRACTOR FROM A PROPER INSTALLATION, COMPLIANCE WITH THE <br />DRAWINGS, SPECIFICATIONS, CODES, STANDARDS, SITE CONSTRAINTS, ETC. OR <br />COORDINATION OF THE WORK. <br />C. PROVIDE SUBMITTALS FOR THE FOLLOWING: <br />1. LIGHTING FIXTURES & LIGHTING CONTROLS <br />2. FIRE DETECTION & ALARM SYSTEM <br />22. WIRING METHODS <br />A. BRANCH CIRCUITS - EMT ABOVE GRADE. <br />B. TELECOMMUNICATIONS, FIRE ALARM, LOW VOLTAGE, ETC. - <br />EMTABOVEGRADE. <br />C. FLEX- SHALL BE USED FOR FINAL CONNECTIONS TO VIBRATING EQUIPMENT& <br />MAYBE SUBSTITUTED FOR EMT WHEN RUN CONCEALED WITHIN WALLS & <br />CEILINGS. FLEX SHALL NOT BE USED FOR HOME RUNS. FLEX SHALL BE <br />LIQUIDTIGHT TYPE WHERE INSTALLED OUTDOORS. <br />D. MC CABLE - MAY NOT BE USED, EXCEPT FOR LIGHTING FIXTURE WHIPS IN <br />ACCESSIBLE CEILING SPACES. <br />23. RACEWAYS <br />A. RACEWAYS AND CABLES THROUGHOUT THE FACILITY SHALL BE RUN CONCEALED IN <br />THE WALLS, ABOVE THE CEILING OR BELOW THE FLOOR WHERE POSSIBLE, EXCEPT, <br />EXPOSED WITHIN UTILITY & OTHER NON-PUBLIC SPACES. WITHIN PUBLIC SPACES, <br />WHERE DUE TO THE BUILDINGS CONSTRUCTION, IT IS NOT POSSIBLE TO ROUTE <br />RACEWAYS & CABLES CONCEALED, RACEWAYS MAY BE RUN EXPOSED WHEN <br />APPROVED BY ARCHITECT. EXPOSED RACEWAYS SHALL BE RUN AS NEATLY & <br />UNOBTRUSIVELY AS POSSIBLE, SUPPORTED AS REQUIRED, PARALLEL OR AT RIGHT <br />ANGLES TO CEILINGS, WALLS & STRUCTURAL MEMBERS. <br />B. RACEWAYS SHALL BE AS FOLLOWS, UNLESS NOTED OTHERWISE: <br />1. INTERIOR CONCEALED SPACES - ELECTRICAL METALLIC TUBING (EMT) WITH <br />FLEXIBLE METAL CONDUIT (FLE)) FOR FINAL CONNECTIONS. <br />2. INTERIOR, EXPOSED IN UTILITY ROOMS & OTHER NON-PUBLIC SPACES - <br />ELECTRICAL METALLIC TUBING (EMT). <br />3. INTERIOR, EXPOSED IN ROOMS, CORRIDORS & THE LIKE WHERE READILY <br />VISIBLE TO BUILDING OCCUPANTS - SURFACE METAL RACEWAY (SMR). <br />C. RACEWAYS SHALL BE SIZED SO THATTHE CABLE FILL DOES NOT EXCEED 40%, <br />EXCEPT, MINIMUM CONDUIT(& EQUIVALENT SURFACE METAL RACEWAY) SIZES <br />SHALL BE AS FOLLOWS, UNLESS NOTED OTHERWISE: <br />1. 3/4" - BRANCH CIRCUITS, EXCEPTAS NOTED BELOW. <br />2. 1/2" - BRANCH CIRCUTS SERVING A SINGLE DEVICE LOCATION. <br />3. 1"-HOMERUNS. <br />4. 1" -TELECOMMUNICATIONS RACEWAYS TERMINATING IN A SINGLE DEVICE. <br />5. 1 1/4" -AUDIO/VIDEO SYSTEMS. <br />D. ELECTRICAL METALLIC TUBING SHALL BE ELECTRO-GALVANIZED STEEL. <br />E. RIGID ALUMINUM CONDUIT SHALL BE HEAVY WALL. <br />F. SURFACE METAL RACEWAYS SHALL BE HEAVY -GAUGE ZINC PLATED OR <br />GALVANIZED STEEL, WIREMOLD SERIES 700 OR EQUAL. <br />G. CONDUIT SHALL BE RUN CONCEALED UNLESS NOTED OR INDICATED OTHERWISE, <br />EXCEPT, FINAL RISERS AND DROPS TO EQUIPMENT, SURFACE MOUNTED PANELS, <br />ETC. SHALL BE EXPOSED, AND CONDUIT WITHIN THE MECHANICAL & ELECTRICAL <br />ROOMS, STORAGE AREAS, ETC. MAY BE RUN EXPOSED. <br />H. NO CONDUIT SHALL BEND MORE THAN 270 DEGREES BEFORE THE END OF ITS <br />RUN. BENDS IN CONDUITS SHALL BE MADE WITHOUT FLATTENING, KINKING OR <br />REDUCING THE CROSS -SECTIONAL AREA OF THE CONDUIT. CONDUIT CUTS SHALL <br />BE MADE SQUARE WITH A PROPER CUTTING TOOL. THE INSIDE AND OUTSIDE OF <br />ALL CONDUIT ENDS SHALL BE REAMED TO ELIMINATE BURRS AND ROUGH EDGES, <br />THEN WIPED CLEAN. <br />I. SUITABLE BUSHINGS SHALL BE USED ON ALL CONDUIT TERMINATIONS. <br />J. CONDUIT SYSTEMS SHALL BE COMPLETE, SNAKED AND CLEANED BEFORE <br />PULLING ANY CABLE. <br />24. RACEWAY FITTINGS <br />A. CONNECTORS, COUPLINGS, ETC. FOR EMT SHALL BE STEEL SET -SCREW TYPE, <br />EXCEPT, STEEL RAINTIGHT COMPRESSION TYPE IN POTENTIALLY WET OR DAMP <br />LOCATIONS. <br />B. FITTINGS FOR MC CABLE SHALL BE OF A TYPE SPECIFICALLY DESIGNED FOR THE <br />PURPOSE AND INCLUDE A NON-METALLIC ANTI -SHORT BUSHING. <br />25. BOXES <br />A. BOXES SHALL ACCOMMODATE ANY DEVICE TO BE INSTALLED AND SHALL BE <br />SIZED AS REQUIRED BY THE APPLICABLE CODES FOR NUMBER AND SIZE OF <br />CONDUITS AND CABLES ENTERING AND LEAVING; EXCEPT MINIMUM AS NOTED <br />BELOW. <br />B. INDOOR BOXES ABOVE GRADE IN DRY LOCATIONS SHALL BE STANDARD STAMPED <br />GALVANIZED STEEL TYPE, SUITABLE FOR EMBEDMENT IN CONCRETE AND/OR <br />MASONRY WHERE REQUIRED. <br />C. UNLESS NOTED OTHERWISE, LARGER SIZE PULL AND JUNCTION BOXES SHALL BE <br />FABRICATED FROM CODE GAUGE GALVANIZED STEEL. <br />D. SWITCH, OUTLET, DEVICE, ETC. BOXES SHALL BE SINGLE OR GANGED TO <br />ACCOMMODATE THE REQUIRED NUMBER OF DEVICES; EXCEPT, FLUSH MOUNTED <br />BOXES SHALL BE MINIMUM 41NCHES SQUARE FOR CONDUITS 1 INCH OR LESS AND <br />4-11/16 INCHES SQUARE FOR LARGER CONDUITS. BOXES CONTAINING A SINGLE <br />DEVICE SHALL BE MINIMUM 1-1/2 INCHES DEEP. BOXES CONTAINING MULTIPLE <br />DEVICES SHALL BE MINIMUM 2-1/8 INCHES DEEP. FLUSH MOUNTED BOXES SHALL <br />BE EQUIPPED WITH PLASTER RINGS AND SUITABLE WALLPLATES. SURFACE <br />MOUNTED BOXES SHALL HAVE RAISED SURFACE TYPE COVERS. <br />E. TELECOMMUNICATIONS DEVICE BOXES SHALL BE SINGLE GANG, FLUSH MOUNTED <br />BOXES SHALL BE MINIMUM 4-11/16 INCHES SQUARE BY MINIMUM 2-1/8 INCHES <br />DEEP. FLUSH MOUNTED BOXES SHALL BE EQUIPPED WITH PLASTER RINGS AND <br />SUITABLE WALLPLATES. <br />F. AUDIO/VIDEO SYSTEM DEVICE BOXES SHALL BE TWO -GANG, FLUSH MOUNTED <br />BOXES SHALL BE MINIMUM 51NCHES SQUARE BY MINIMUM 2-1/2 INCHES <br />DEEP. FLUSH MOUNTED BOXES SHALL BE EQUIPPED WITH PLASTER RINGS AND <br />BLANK WALLPLATES. <br />26. WIRING <br />A. ALL WIRING SHALL BE ENCLOSED WITHIN THE RACEWAY SYSTEM, EXCEPT, <br />TELECOMMUNICATIONS, FIRE ALARM AND CLASS 2 LOW VOLTAGE CABLING MAY <br />BE BUNDLED TOGETHER AND SUPPORTED OPEN IN ACCESSIBLE CEILING SPACES. <br />B. ALL WIRING BETWEEN FLOORS SHALL BE ENCLOSED WITHIN A RACEWAY SYSTEM. <br />C. PROTECT"OPEN" CABLE WIRING FROM ROUGH AND/OR SHARP EDGES ON <br />SUPPORTS, STRUCTURAL MEMBERS, ETC. AS REQUIRED DURING INSTALLATION. <br />D. WIRE AND CABLE SIZES INDICATED AND/OR SPECIFIED ARE MINIMUMS ONLY AND <br />SHALL BE INCREASED AS REQUIRED DUE TO NEC, SYSTEM, LOAD, <br />VOLTAGE DROP, ETC. REQUIREMENTS. <br />E. BRANCH CIRCUIT& EQUIPMENT GROUND CABLES SHALL BE 1/C COPPER, <br />STRANDED, #12 AWG UNLESS NOTED OTHERWISE, WITH 600V TYPE XHHW OR <br />THHN/THWN INSULATION. <br />F. CABLE SHALL BE INSTALLED OR DRAWN INTO THE CONDUIT SYSTEM ONLY AFTER <br />ALL WORK OF ANY NATURE THAT COULD CAUSE INJURY TO THE CABLE IS <br />COMPLETED. THE CONDUIT SYSTEM SHALL BE COMPLETE, SNAKED AND CLEANED <br />BEFORE PULLING ANY CABLE. <br />G. "OPEN" CABLES SHALL BE BUNDLED AND SUPPORTED FROM PERMANENT <br />STRUCTURAL MEMBERS OF THE BUILDING, EITHER DIRECTLY OR INDIRECTLY, WITH <br />SUITABLE HOOKS. SUPPORT SPACING SHALL NOT EXCEED 5 FEET. PROTECT <br />"OPEN" CABLES DURING INSTALLATION IN CEILING SPACES. CABLES SHALL NOT <br />INTERFERE WITH THE REMOVAL OF PIPES OR EQUIPMENT FOR MAINTENANCE OR <br />REPAIR. ALL "OPEN" CABLE SHALL BE KEPTA MINIMUM OF 6INCHES FROM PIPES, <br />DUCTS, AND OTHER ITEMS PRODUCING HEAT. SUPPORT"OPEN" CABLES A <br />MINIMUM OF 6 INCHES ABOVE T-BAR CEILINGS. TAPE AND CABLE TIES ARE NOT <br />APPROVED METHODS OF FASTENING CABLES. <br />27. CABLE SUPPORTS <br />A. SUPPORTS FOR CABLES RUN "OPEN" ABOVE CEILINGS AND THE LIKE SHALL BE <br />WIDE BASE TYPE J-HOOK ASSEMBLIES. SUPPORTS SHALL BE MADE OF <br />GALVANIZED STEEL AND HAVE MINIMUM 2" DIAMETER. <br />B. SUPPORTS FOR LARGE BUNDLES OF CABLES (MORE THAN 50 CABLES) RUN OPEN <br />ABOVE CEILINGS, IN CRAWLSPACES AND THE LIKE SHALL BE WIDE BASE FABRIC <br />LOOP, RE -ENTERABLE ASSEMBLIES. <br />28. GROUNDING: <br />A. ALL ELECTRICAL EQUIPMENT, BOXES, DEVICES, SHALL BE PROVIDED WITH A <br />GROUND FAULT RETURN PATH BY MEANS OF THE INTEGRITY OF THE METALLIC <br />CONDUIT SYSTEM (WHERE APPLICABLE) & AN INSULATED GROUNDING <br />CONDUCTOR INSTALLED WITH THE CIRCUIT CONDUCTORS. CONDUIT SHALL BE <br />CLOSELY & TIGHTLY FITTED IN COUPLINGS, CONNECTORS, ETC. AND BE PROPERLY <br />BONDED TO PROVIDE AN ELECTRICALLY CONTINUOUS LOW RESISTANT GROUND <br />PATH. CONTINUITY TESTS SHALL BE MADE TO VERIFY THE CONTINUITY OF THE <br />GROUNDING SYSTEM & ALL GROUND FAULT RETURN PATHS. <br />B. EQUIPMENT GROUND CABLES SHALL BE 1/C COPPER, WITH 600V TYPE XHHW OR <br />THHN/THWN INSULATION. <br />29. WIRING DEVICES <br />A. WIRING DEVICES SHALL BE SPECIFICATION GRADE, IVORY COLOR WHEN INSTALLED <br />ON THE NORMAL BRANCH AND RED COLOR WHEN INSTALLED ON THE <br />CRITICAL BRANCH. <br />B. GENERAL PURPOSE RECEPTACLES SHALL BE STRAIGHT BLADE, 15 AMP, 125 VOLT. <br />C. GROUND FAULT INTERRUPTER (GFH) TYPE RECEPTACLES SHALL BE DUPLEX CLASS <br />A, 15 AMP, 125 VOLT. <br />D. RECEPTACLES WITHIN EXAM, PROCEDURE, OPERATING, PHYSICAL THERAPY AND <br />SIMILAR ROOMS SHALL BE HOSPITAL GRADE. <br />E. FLUSH MOUNTED DEVICES SHALL HAVE SMOOTH SPECIFICATION GRADE <br />STAINLESS STEEL WALLPLATES. <br />F. ALL OUTLETS SHALL BE LABELED WITH THE PANEL AND CIRCUIT NUMBER(S) FROM <br />WHICH HE DEVICE IS FED. LABELS SHALL BE HEAVY DUTY ADHESIVE TYPE, CLEAR <br />WITH BLACK LETTERS ON LIGHT COLORED DEVICES AND CLEAR WITH WHITE <br />LETTERS ON DARK COLORED DEVICES. LETTERING SHALL BE 1/4" MINIMUM. <br />SELF-ADHESIVE CIRCUIT NUMBERS, MASKING TAPE, PLASTIC PUNCH TYPE "DYMO" <br />LABELS, ETC. ARE NOT ACCEPTABLE. <br />30. LIGHTING <br />A. THE LIGHTING SYSTEMS AND ALL CONTROLS SHALL BE IN ACCORDANCE WITH THE <br />WASHINGTON STATE ENERGY CODE (WSEC). <br />B. LIGHT EMITTING DIODE (LED) LUMINAIRES SHALL HAVE A LUMINOUS EFFICIENCY OF <br />AT LEAST 90 LUMENS/W, AN ESTIMATED LIFE OF AT LEAST 50,000 HOURS AT 70% <br />LUMEN MAINTENANCE, AND SHALL INCLUDE A MINIMUM 5-YEAR WARRANTY ON <br />THE ENTIRE LUMINAIRE INCLUDING THE DRIVER. THE LUMINAIRE AND LEDS SHALL <br />HAVE BEEN TESTED IN ACCORDANCE WITH LM-79 AND LM-80. <br />C. FIXTURES, LUMINAIRES, POLES, ETC. SHALL INCLUDE ALL NECESSARY MOUNTING <br />AND CONNECTING ACCESSORIES. PROVIDE NEW MOUNTING HARDWARE AND <br />NEW SUPPORT WIRES FOR EXISTING FIXTURES TO BE RE -INSTALLED. <br />D. CONTRACTOR & LIGHTING FIXTURE SUPPLIER SHALL VERIFY DESCRIPTION & <br />CATALOG NUMBERS IN LIGHTING FIXTURE SCHEDULE ON THE DRAWINGS MATCH <br />AND MOUNTING REQUIREMENTS ARE CORRECT. ADVISE ENGINEER OF ANY <br />CONFLICTS OR DISCREPANCIES. <br />31. LIGHTING CONTROLS <br />A. OCCUPANCY SENSORS SHALL BE COMBINATION PASSIVE INFRARED & ULTRASONIC <br />TYPE, CEILING OR WALL MOUNTED (AS INDICATED), WITH ADJUSTABLE TIME DELAY, <br />ADJUSTABLE SENSITIVITY, AND AN LED INDICATOR. LENSES SHALL BE AS REQUIRED <br />FOR THE APPLICATION, THE SENSORS SHALL BE ABLE TO DETECTTHE DIFFERENCE <br />BETWEEN A HUMAN BODY AND THE BACKGROUND SPACE. OCCUPANCY. <br />OCCUPANCY SENSORS SHALL BE GREENGATE OAC-DT-2000, HUBBELL OMNIDT2000, <br />LUTRON LOS-CDT-2000, PLC MULTIPOINT OCS-222-1, WATT STOPPER DT-300, OR <br />APPROVED EQUAL. <br />B. POWER PACKS FOR USE WITH LOW VOLTAGE SWITCHING SHALL BE REMOTE <br />MOUNTED, 120 OR 277 VOLTAC INPUT (AS REQUIRED), 24 VOLT DC OUTPUT, WITH <br />SINGLE RELAY AND CONTACTS RATED MINIMUM 20 AMPS AS REQUIRED. RELAYS/ <br />POWER PACKS SHALL BE CAPABLE OF CONTROLLING AND/OR BEING CONTROLLED <br />BY UP TO MINIMUM 3 SENSORS AND SHALL BE CAPABLE OF SELECTION BETWEEN <br />AUTOMATIC ON MODE AND MANUAL ON MODE. POWER PACKS SHALL BE CAPABLE <br />OF BEING CONNECTED TO A MOMENTARY CONTACT SWITCH FOR MANUAL SWITCHING <br />OF CONNECTED LOADS. OCCUPANCY SENSORS RELAYS/POWER PACKS SHALL BE <br />OF THE SAME MANUFACTURER AND SPECIFICALLY DESIGNED FOR USE WITH THE <br />OCCUPANCY SENSORS, GREENGATE SP20-RD4, HUBBELL UVPPM, LUTRON PP -DV, <br />PLC MULTIPOINT PP900-AX, WATT STOPPER BZ-150, OR APPROVED EQUAL. <br />C. WALL SWITCHES FOR ON -OFF APPLICATIONS (MANUAL -ON APPLICATIONS) SHALL BE <br />MOMENTARY CONTACT TYPE, IVORY COLOR, LEVITON MODEL 1061, GREENGATE <br />MODEL GMT, HUBBELL LVSiHD, PASS & SEYMOUR 1250, OR APPROVED EQUAL. <br />D. LOW VOLTAGE DIMMER SWITCHES FOR 0-10 VOLT DIMMING APPLICATIONS SHALL BE <br />IVORY COLOR, LUXDRIVE F019, OR APPROVED EQUAL. <br />E. MOT10N SENSOR SWITCHES SHALL BE ULTRASONIC OR PASSIVE INFRARED TYPE, <br />WALL MOUNTED, IVORY COLOR, 120-277 VOLT, RATED MINIMUM 1200 WATT, <br />ADJUSTABLE SENSITIVITY, ADJUSTABLE TIME DELAY, SWITCH FOR MANUAL CONTROL <br />AND VANDAL RESISTANT HARD LENS. BUTTONS ON THE FACE OF THE SWITCHES <br />SHALL OPERATE IN TOGGLE MODE TO MANUALLY TURN ON/OFF CONNECTED LIGHTING <br />LOADS. MOT10N SENSOR SWITCHES SHALL BE WATTSTOPPERTYPE PW-301, <br />HUBBELL TYPE LHMTSI, SQUARED TYPE PIR, SENSOR SWITCH TYPE WSX-PDT, OR <br />GREENGATE ONW-D-1001-MV, OR APPROVED EQUAL. <br />F. EMERGENCY LIGHTING RELAYS SHALL BE 120V OR 277V RATED, 20 AMPS, CAPABLE <br />OF TRANSFERRING LIGHTING LOADS TO THE EMERGENCY POWER SOURCE WHEN <br />NORMAL POWER IS INTERRUPTED. RELAY SHALL CONSIST OF A SINGLE SELF- <br />CONTAINED UNIT COMPLETE WITH VOLTAGE SENSING AND RELAY SWITCHING <br />CIRCUITRY, TEST SWITCH, REMOTE ACTIVATION AND INDICATOR LIGHTS. RELAY SHALL <br />BE UL LISTED FOR FIELD INSTALLATION AND SHALL COMPLY WITH UL 924 AS <br />EMERGENCY LIGHTING EQUIPMENT. RELAY SHALL BE BODINE BLCD-20B, <br />WATTSTOPPER ELCU-200, OR APPROVED EQUAL. <br />32. FIRE DETECTION & ALARM SYSTEM (EXISTING) <br />A. SYSTEM SHALL BE A MODIFICATION AND EXPANSION TO THE EXISTING EDWARDS <br />SYSTEMS EST-3 SYSTEM IN THE BUILDING. ALL COMPONENTS SHALL BE <br />SPECIFICALLY DESIGNED TO INTEROPERATE WITH THE EXISTING FIRE DETECTION <br />& ALARM SYSTEM. <br />B. EXISTING SYSTEM SHALL BE MODIFIED AND NEW COMPONENTS SHALL BE <br />INSTALLED BY, OR UNDER THE DIRECT SUPERVISION OF, A QUALIFIED <br />REPRESENTATIVE OF THE MANUFACTURER. PROVIDE CALCULATIONS TO SUPPORT <br />THE SIZE OF THE EXISTING STAND-BY BATTERIES WITH THE ADDITION OF NEW <br />DEVICES. PROVIDE LARGER STAND-BY BATTERIES IF REQUIRED. <br />C. THE CONTRACTOR SHALL SUBMIT COMPLETE SETS OF FIRE ALARM SYSTEM <br />SUBMITTALS AS REQUIRED TO THE CITY OF EVERETT FIRE MARSHAL FOR <br />APPROVAL AND PAY THE PLAN REVIEW FEES. <br />D. THE CONTRACTOR SHALL ARRANGE FOR INSPECTIONS AND PAY FOR ALL <br />REQUIRED LICENSES, PERMITS, INSPECTIONS, PLAN REVIEW FEES AND ANY <br />OTHER FEES. ALL NECESSARY PERMITS AND APPROVALS SHALL BE OBTAINED <br />PRIOR TO THE START OF CONSTRUCTION. <br />E. SYSTEM SHALL COMPLY WITH ALL REQUIREMENTS OF NFPA#72 (NATIONAL FIRE <br />ALARM CODE), INTERNATIONAL FIRE CODE, INTERNATIONAL BUILDING CODE, ADA & <br />CITY OF EVERETT REQUIREMENTS. <br />F. DEVICES & DETECTORS <br />1. DEVICES (SMOKE DETECTORS, HEAT DETECTORS, PULL STATIONS, ETC.) <br />SHALL BE 2 WIRE, 24 VDC, SUITABLE FOR USE WITH & COMPLETELY <br />COMPATIBLE WITH THE EXISTING FIRE DETECTION & ALARM SYSTEM. <br />2. DETECTORS SHALL BE 2 PIECE, CONSISTING OF A BASE AND SEPARATE <br />PLUG-IN HEAD. <br />3. PULL STATIONS SHALL BE NON -CODED, MANUAL, SINGLE ACTION, ENCLOSED <br />MANUAL RESET TYPE, FLUSH MOUNTED. MATCH EXISTING. <br />4. SMOKE DETECTORS SHALL BE IONIZATION OR PHOTOELECTRIC TYPE, <br />SUITABLE FOR ITS FUNCTION & LOCATION WITH SCREEN (OR OTHER METHOD) <br />TO PREVENT INSECTAND DUST CONTAMINATION, TEST SWITCH & LATCHING <br />LED. SMOKE DETECTORS SHALL BE SUITABLE FOR THE TEMP. & HUMIDITY <br />FLUCTUATIONS, AND BE IMMUNE TO ELECTRICAL NOISE FROM H.I.D. AND <br />FLUORESCENT LIGHT FIXTURES, ELECTRONIC EQUIPMENT, ETC. IONIZATION <br />DETECTORS SHALL BE DUAL CHAMBER, ADJUSTABLE SENSITIVITY. <br />PHOTOELECTRIC DETECTORS SHALL HAVE A SYMMETRICAL OPTICAL <br />CHAMBER, SHIELDED FROM AMBIENT LIGHT, WITH INFRARED LIGHT SOURCE. <br />G. SIGNALING DEVICES <br />1. FIRE ALARM SPEAKERS SHALL BE 70 VOLT DC, MULTI -TAP AND SET AS REQUIRED <br />TO PROVIDE THE MINIMUM ACCEPTABLE OR CODE REQUIRED SOUND LEVEL. <br />2. FIRE ALARM STROBES SHALL BE 24 VOLT DC, MINIMUM AS INDICATED <br />(EXCEPT AS REQUIRED BY ADA OR THE AUTHORITY HAVING JURISDICTION TO <br />PROVIDE THE MINIMUM REQUIRED INTENSITY LEVEL THROUGHOUT THE <br />SPACE) WITH CLEAR POLYCARBONATE LENS AND FIRE LETTERING. STROBES <br />THROUGHOUT SPACE SHALL BE SYNCHRONIZED. <br />3. FIRE ALARM SPEAKER/STROBES SHALL BE AS ABOVE; EXCEPT, COMBINED INTO <br />A SINGLE ASSEMBLY. <br />DEMOLITION: <br />1. CONTRACTOR SHALL REMOVE EXISTING EQUIPMENT, FIXTURES, DEVICES, ETC. AS <br />INDICATED IN THE WORK AREA AND ALL ASSOCIATED CONDUIT, BOXES, <br />CABLES, ETC. SHALL BE REMOVED TO THEIR POINT OF ORIGIN &/OR DESTINATION. <br />2. UNLESS NOTED OTHERWISE, CONCEALED RACEWAYS ARE ALLOWED TO REMAIN, <br />EXCEPT, WIRING SHALL BE REMOVED. EXISTING CONCEALED RACEWAYS ARE <br />ALLOWED TO BE RE -USED IF IN GOOD CONDITION & SUITABLE FOR THE NEW <br />INSTALLATION. <br />3. EXISTING FEEDERS, CIRCUITS, CONDUITS, CABLES, ETC. INTERRUPTED DUE TO THE <br />SYSTEM UPGRADE SHALL BE RE -CONNECTED AS REQUIRED TO MAINTAIN THE <br />ORIGINAL FUNCTION. <br />4. ALL SURPLUS MATERIAL REMOVED DURING THE DEMOLITION SHALL BE INSPECTED <br />BY THE OWNER, AND THOSE ITEMS SELECTED SHALL REMAIN THE PROPERTY OF <br />THE OWNER. ALL REMAINING SURPLUS MATERIALS SHALL BE REMOVED FROM THE <br />SITE & DISPOSED OF BY THE CONTRACTOR ACCORDING TO ALL APPLICABLE <br />REGULATIONS. <br />i727 Oakes Ave. <br />Suite 100 <br />Everett, WA 95201 <br />REVISIONS <br />v1P� R. fEA <br />0 <br />z cn <br />Pow SI4794���' <br />Cy.. ONSATLE� Y <br />cz <br />�0 `O_ <br />cz <br />IL CZ <br />n' L <br />W W <br />U m <br />cz^ <br />I V/ <br />O <br />3 L CL <br />O <br />O O O <br />IL LL CL <br />2376 <br />oeAw KL <br />_­e. BD <br />CONSTRUCTION SET <br />12-17-2024 <br />ELECTRICAL - <br />SPECIFICATIONS <br />E0.2 <br />City of Everett Permit Services <br />EVERETT Reviewed for Permit 01/14/2025 <br />