Laserfiche WebLink
JOEY <br /> D 51 N <br /> GENERAL NOTES <br /> CODE <br /> DESIGN IS IN ACCORDANCE WITH THE 2018 INTERNATIONAL RESIDENTIAL CODE(I.R.C.) <br /> ADULT FAMILY HOME <br /> A DWELLING,LICENSED BY THE STATE OF WASHINGTON DEPARTMENT OF SOCIAL AND HEALTH SERVICES, <br /> IN WHICH A PERSON OR PERSONS PROVIDE PERSONAL CARE,SPECIAL CARE,ROOM AND BOARD TO MORE <br /> THAN ONE BUT NOT MORE THAN SIX ADULTS WHO ARE NOT RELATED BY BLOOD OR MARRIAGE TO THE <br /> PERSON OR PERSONS PROVIDING THE SERVICES.AN EXISTING ADULT FAMILY HOME MAY PROVIDE <br /> SERVICES TO UP TO EIGHT ADULTS UPON APPROVAL FROM THE DEPARTMENT OF SOCIAL AND HEALTH <br /> SERVICES IN ACCORDANCE WITH RCW 70.128.066. <br /> FOUNDATIONS <br /> EXTEND FOOTINGS TO FIRM UNDISTURBED SOIL,ASSUMED BEARING CAPACITY OF 1500 PSF.ALL <br /> EXTERIOR FOOTINGS SHALL EXTEND A MINIMUM OF V-6"BELOW ADJACENT EXTERIOR FINISHED GRADE. <br /> I.—N <br /> CAST-IN-PLACE CONCRETE fn cc) <br /> F'c=3,000 PSI @ 28 DAYS.MINIMUM 5-1/2 SACKS OF CEMENT PER CUBIC YARD OF CONCRETE AND A 0 <br /> MAXIMUM OF 6-3/4 GALLONS OF WATER PER 94#SACK OF CEMENT.NO SPECIAL INSPECTION REQUIRED. <br /> TOTAL AIR ENTRAINMENT SHALL NOT BE LESS THAN 5 PERCENT OR MORE THAN 7 PERCENT.MAXIMUM <br /> SIZED AGGREGATES IS 1-1/2 INCHES.MAXIMUM SLUMP IS 4INCHES.ALL REINFORCING STEEL DOWELS, <br /> ANCHOR BOLTS AND OTHER INSERTS SHALL BE SECURED IN POSITION PRIOR TO POURING CONCRETE. <br /> ANCHOR BOLTS FOR PRESSURE TREATED SILL PLATES TO FOUNDATION WALLS TO BE%"DIAMETER WITH ln <br /> 7 INCH MINIMUM EMBEDMENT INTO CONCRETE AND MAXIMUM SPACING OF 2 FEET ON CENTER UNLESS z V <br /> NOTED OTHERWISE ON THE PLANS.MINIMUM 2 BOLTS PER SILL PLATE PIECE.ONE BOLT TO BE PLACED 0 W <br /> WITHIN 6 INCHES OF EACH END OF THE SILL PLATE. <br /> — --- - - - — — W Q (V <br /> - — CARPENTRY U M> <br /> ALL GRADES SHALL CONFORM TO W WPA GRADING RULES FOR WESTERN LUMBER,LATEST EDITION. O N W <br /> PROVIDE CUT WASHERS UNDER ALL NUTS AND BOLTS BEARING AGAINST WOOD.ALL WOOD IN CONTACT <br /> --------- - - -- - WITH CONCRETE SHALL BE PRESSURE TREATED PER PRESERVATIVE TREATMENT NOTE.FASTENERS <br /> INSTALLED IN PRESERVATIVE TREATED WOOD SHALL BE HOT-DIPPED GALVANIZED PER I.R.C.SECTION <br /> --- - - - - R319.3.NAILING SHALL CONFORM WITH I.R.C.TABLE R602.3(1)&R802.10 OR I.B.C.TABLE 2304.9.1.ALL <br /> '--'— --_-- STRUCTURAL LUMBER SHALL BE AS NOTED BELOW: <br /> 2x STUDS HEM-FIR#2 ---Fb=850 PSI <br /> 2x FLOOR&ROOF JOIST HEM-FIR#2-----Fb=850 PSI <br /> 4x BEAMS DOUG-FIR/LARCH#2---Fb=875 PSI <br /> ------- --- 6x BEAMS DOUG-FIR/LARCH#2---Fb=850 PSI <br /> COLUMNS DOUG-FIR/LARCH#2---Fb=875 PSI <br /> LUMBER NOT NOTED DOUG FIR/LARCH#2 Fb"850 PSI <br /> MISCELLANEOUS HANGERS TO BE PROVIDED BY SIMPSON COMPANY.ALL HANGERS SHALL BE FASTENED <br /> - TO WOOD WITH PROPER NAILS ALL HOLES SHALL 8E NAILED MACHINE BOLTS TO BE A-307 ANCHOR <br /> BOLTS INTO CONCRETE SHALL BE%"DIAMETER WITH 7 INCHES OF EMBEDMEND INTO CONCRETE UNLESS <br /> NOTED OTHERWISE ON THE PLANS.ALL NAILS SHALL BE COMMON WIRE NAILS.NAILING SHALL BE IN <br /> ACCORDANCE WITH I.B.C.SCHEDULE.ifid COMMON NAIL DIAMETER-(0.162 INCH).LAMINATED STUDS <br /> SHALL BE NAILED WITH(2)ROWS ifid COMMON NAILS @ 6"O.C. <br /> FLOOR SHEATHING W <br /> SHEATHING SHALL BE Y4 INCH TONGUE&GROOVE,A.P.A.RATED SHEATHING.SPAN RATING 4%4 WITH <br /> LONG DIMENSION PERPENDICULAR TO SUPPORTS.UNLESS NOTED OTHERWISE NAIL WITH 10d COMMON O <br /> NAILS AT 6 INCHES ON CENTER AT SUPPORTED PANEL EDGES&10 INCHES ON CENTER AT INTERMEDIATE <br /> SUPPORTS.THE FLOOR SHEATHING SHALL BE GLUED TO THE JOIST AND THE TONGUE AND GROOVE <br /> JOINTS WITH AN APPROVED ADHESIVE. } <br /> J <br /> ROOF SHEATHING <br /> SHEATHING SHALL BE%'A.P.A.RATED SHEATHING.SPAN RATING 3Ye INSTALLED WITH LONG DIMENSION <br /> ACROSS SUPPORTS.PANEL END JOINTS SHALL OCCUR AT SUPPORTS.NAIL PANEL EDGES WITH Bd NAILS <br /> AT 41NCHES ON CENTER AND 10 INCHES ON CENTER AT INTERMEDIATE SUPPORTS. ILL <br /> WALL SHEATHING J <br /> `/��'� 7#�� 7#�� I��tI SHEATHING TO BE%s"A.P.A.RATED SHEATHING.SPAN RATING�%.PANEL END JOINTS SHALL OCCUR AT D <br /> RO,I E G T D E S G 1 �I I T I O I � SUPPORTS.NAIL PANEL EDGES WITH 8d NAILS AT 4 INCHES ON CENTER AND 10 INCHES ON CENTER AT <br /> INTERMEDIATE SUPPORTS UNLESS NOTED OTHERWISE ON THE DRAWINGS. Q <br /> 0 <br /> PROPOSED GARAGE CONVERSION INTO REINFORCEMENT W <br /> NEW LIVING DINING KITCHEN, STAFFROOM AND A y=40,000 PSI FOR#5&SMALLER 0 <br /> I y=60,000 PSI FOR#6&LARGER U Q <br /> BATH AND MAIN FLOOR INTERIOR ALTERATION 'TD GI`��re �� GUD�II�Y" Wltl�'1 t}dw�ai w n- <br /> NOTE:ALL BOLTS,WASHERS,NAILS,SCREWS,HANGERS AND FRAMING STRAPS THAT COME INTO <br /> CONTACT WITH ACQ TREATED LUMBER SHALL BE STAINLESS STEEL OR HOT-DIPPED GALVANIZED STEEL. 6 O <br /> OI�N INDEX OF DRAWINGS <br /> ALI SEID MOHAMMED SHEET# DESCRIPTION o«.m.e aa1e: <br /> 2152 HIGHLAND ST <br /> EVERETT, WA - C15201 AO SITE PLAN <br /> Al COVERSHEET IUI� �wC17-7 j} <br /> SITE ADDRESS A2 2018 ALTERATION WSEC,2018 WSEC,AFH NOTES flJnl(1 V 12 2023 U <br /> A3 FASTENING SCHEDULE&DETAILS CIT OF EVERETT <br /> 2152 HIGHLAND 5T Pe Trit Services <br /> EVERETT, WA - C18201 A41 DETAIL SHEET <br /> A5 EXISTING FLOOR PLAN <br /> GEL I A6 EXISTING ELEVATIONS 0 <br /> rAPPROVED <br /> Tf FIRE DEPT.REVIEW W <br /> 00453445303100 VED A7 PROPOSED MAIN FLOOR PLAN <br /> WITH CHANGES NOTED <br /> AND RESUBMIT A8 PROPOSED LOWER FLOOR AND MAIN FLOOR FRAMING PLANED: �_ACHED CHECKLIST/HANDOUT A9 PROPOSED ROOF FRAMING PLAN,BUILDING SECTION AND RAMP PLAN 0 <br /> nce of a permit shall not A10 PROPOSED ELEVATIONS <br /> construed as authority to violate, <br /> E,VERc--- cancel or set aside any provision of 0 <br /> _ the Everett Fire Code or otherOff <br /> c-,�rcf)'i'� �;•'.��:fi. applicable regulations or laws.The W <br /> w <br /> -' issuance of a permit based on z <br /> /� dZ con J <br /> struction documents and other <br /> J 4 r• �4r �✓l /I // data shall not prevent the Fire Code CD Q <br /> / JOUL-Qyct}�� ppSfi slnm�•(et �G ��• ofeOfflrrorsrom requiring the Correction <br /> V r Permit#: 82311-028 ROLLED PLANS <br /> U.l•f <br /> 7 A- I-A I e: - �3 Soe Address: 2132 HIGHLAND AVE A <br /> -- APPROVED Owner: _Val SEID MOHAMMED '�••�r` <br /> Office of Community,Planning&Economic Development Tenant: <br /> l/ <br /> PLANNING DEPARTMENT App.Date: RESIDENTIAL <br /> I O <br /> C/� /yI V I C PermitTYPe: RESIDENTIAL BUILDING <br /> Y L l/ r t DATE: Y3 Subtype: <br /> NaNam 77'-,l1 -BAD[J)(,y�q,?C.AI�LI�'�•-N W� <br /> �CI.J 76' 8 O(.c(� 5"exA O✓�I? r[� Description: TI GARAGE CONVERSION INTO LIVING RM, <br /> �G{vit ll( }-b( :s ✓ltuv-Pi IIU�✓��J✓2 KITCHEN,BATH,STAFFRM Pf f\ 230031 <br /> V <br /> Reviewed 8Y: r Date: <br /> �LDW e Set _Job Site Set <br />