Laserfiche WebLink
• iflrwn i evvem <br />MEMBER REPORT <br />PASSED <br />l <br />Drawing is Conceptual <br />MAIN, MB#2 COL <br />1 plece(s) 6 x 6 HF No.2 <br />Post Height: 8' <br />R�fVn Results <br />Actual <br />Allowed <br />Result <br />LDF <br />Load: CombbtaUon <br />Slenderness <br />17 <br />50 <br />Passed (35%) <br />-• <br />- <br />Compression (Ibs) <br />812$ <br />14894 <br />Passed (55%) <br />1.00 <br />1.0 D + 1.0 L <br />Base Bearing (lbs) <br />8128 <br />898425 <br />Passed (1%) <br />1.0 D + 1.0 L <br />Bending/Corpression <br />0.96 <br />1 <br />Passed (96%) <br />1.00 <br />1.0 D + 1.0 L <br />• Input axial load eccentricity for this design is 16.67% of applicable member side dimension, <br />• Applicable calculations are based on NDS. <br />St/p Yyrpe MafurW' Member Type : Free Standing Post <br />Base Plate Steel Building Code :IBC 2018 <br />-`-- "" - Design Methodology : ASD <br />Max Unbraced Length comments <br />Full Member Length No bracing assumed. <br />Vertical Loads <br />Dad <br />(0.90) <br />Floor utre <br />(L00) <br />Roof Uva <br />(non-maw:1.25) <br />snow <br />(1.15) <br />Oomnwnto <br />1 - Print (lb) <br />1806 <br />5085 <br />Linked from: MB#2, Support 1 <br />2 - Point (lb) <br />992 <br />245 <br />827 <br />1034 <br />Linked from: MB#10, Support 1 <br />Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values Weyerhaeuser expressly disclaims any other warranties <br />related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is <br />responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at <br />Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-i 153 and ESP-1387 <br />andlor tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to <br />www.weyerhaeuser.corr./woodprodtxWdocument-library. <br />input design loads, dimensions and support information have been provided by ForteWEB Software Operator <br />ForteWEB Software Operator lob Notes <br />Chris Lalonde <br />Structural Design Associates <br />(425) 339-0293 <br />ciatonde(asdaeverett.com u e,crh_tc.,aec <br />10/8/2023 9:45:37 PM UTC <br />ForteWEB 0.6, Engine: V8.3.1.5, Data: V8.1.4.1 <br />File Name: 9902 <br />