Pipe Clamps <br /> Fig.28M - Offset Hanger& Restrainer for CPVC Plastic Pipe and IPS Steel Pipe ** ®TOLCO <br /> Size Range: 3/4" (20mm)thru 2" (32mm) C 9US <br /> Material: Steel, Pre-Galvanized LISTED <br /> Function: Designed to be used as a hanger and restrainer for CPVC piping or steel piping <br /> where the "stand-off" design will ease installation by eliminating the need for wood blocking. <br /> Features: <br /> • Flared edge design protects CPVC pipe from any rough or abrasive surfaces <br /> • Unique snap-on design holds pipe firmly in place and allows retrofit type of installation <br /> •The "Stand-Off" design eliminates the need for wood block extension <br /> • Can be installed on horizontal or vertical piping regardless of mounting surface orientation A <br /> •Attaches easily to wood structure with two hex head self-threading screws furnished with <br /> product <br /> • Installs easily using rechargeable electrical driver with 5/16 (7.9mm) extension socket I <br /> eliminating impact tool damage to pipe Pt. <br /> •Attaches easily to steel, minimum 18 gauge (1.024mm)with (2) 1/4" x 1" tek type self <br /> drilling tapping screws C <br /> •cULus Listed as a hanger and a restrainer for fire sprinkler piping <br /> Installation Note: When installed in wood structural members and threads from the B <br /> #10 x 1"screws are exposed, use Fig. 27B speed nut to secure <br /> Approvals: Underwriters Laboratory Listed in the USA(UL)and Canada (cUL) <br /> to support automatic fire sprinkler systems. <br /> May be installed into wood using fasteners screws. <br /> Meets and exceeds the requirements of NFPA 13, <br /> 13R and 13D. Fig. 28M satisfies the UL vertical <br /> restraint requirements where needed. <br /> Order By: Figure number and pipe size Fig.27B <br /> ? (2)Required <br /> Patent#7,744,042 <br /> ** With reduced spacing, consult factory. NNW <br /> b Hanger and Restraint <br /> r---- Application <br /> L--- <br /> 4 _-_d __ <br /> --- Restraint Fig.27B ! II R <br /> (1)Required E5 <br /> 11 <br /> --� High Side of Hanger j \_ c. <br /> Restraint <br /> Detail A <br /> Hanger Application <br /> Pipe Size A Hole Dia.B C Max Spacing* Approx.Wt./100 <br /> Part No. in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) lbs. (kg) <br /> 28M-3/4 3/4" (20) 2" (50.8) 3/16" (4.8) 35/16" (84.1) 5'-6" (1676) 9 (4.1) <br /> 28M-1 1" (25) 21/8" (54.0) 3/16" (4.8) 31/2" (88.9) 6'-0- (1829) 12 (5.4) <br /> 28M-11/4 11/4" (32) 25/16" (58.7) 3/16" (4.8) 31/2" (88.9) 6'-6- (1981) 13 (5.9) <br /> 28M-11/2 11/2" (49) 27/16" (61.9) 3/16" (4.8) 37/8" (98.4) T-0" (2133) 14 (6.3) <br /> 28M-2 2" (50) 25/8" (66.7) 3/16" (4.8) 47/16"(112.7) 8'-0- (2438) 15 (6.8) <br /> * Required per NFPA 13 for CPVC plastic pipe <br /> All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. <br /> B-Line <br /> Fire Protection Solutions <br /> 41 by EJ-N <br />