My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4015 FRIDAY AVE 2025-10-24
>
Address Records
>
FRIDAY AVE
>
4015
>
4015 FRIDAY AVE 2025-10-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/24/2025 8:17:48 AM
Creation date
5/6/2025 3:16:25 PM
Metadata
Fields
Template:
Address Document
Street Name
FRIDAY AVE
Street Number
4015
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
56
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2018 Washington State Energy Code — Residential <br />Prescriptive Energy Code Compliance for All Climate Zones in Washington <br />Single Family New & Additions (effective February 1,'2021) <br />Table 406.3 - Energy Credits (Single Family) <br />Option <br />--- -- — - — Description - - ------ - _ --- - — --- <br />� T Credi_t_s: SF <br />5. EFFICIENT WATER HEATING OPTIONS <br />Only one option from Items 5.2 through 5.6 may be selected in this category. Item 5.1 may be combined with a <br />A drain water heat recovery unit(s) shall be installed, which captures waste water heat from <br />all and only the showers, and has a minimum efficiency of 40% if installed for equal flow or a <br />!minimum efficiency of 54% if installed for unequal flow. Such units shall be rated in <br />accordance with CSA B55.1 or IAPMO IGC 346-2017 and be so labeled. <br />5.1 <br />To qualify to claim this credit, the building permit drawings shall include a plumbing diagram <br />that specifies the drain water heat recovery units and the plumbing layout needed to install it. <br />Labels or other documentation shall be provided that demonstrates that the unit complies <br />with the standard. <br />0.5 <br />!Water heating system shall include one of the following: <br />5.2 Energy Star rated gas or propane water heater with a minimum UEF of 0.80. 5 0.5 <br />;Water heating system shall include one of the following: <br />Energy Star rated gas or propane water heater with a minimum UEF of 0.91 or <br />!Solar water heating supplementing a minimum standard water heater. Solar water heating <br />,will provide a rated minimum savings of 85 therms or 2000 kWh based on the Solar Rating and <br />Certification Corporation (SRCC) Annual Performance of OG-300 Certified Solar Water Heating <br />5.3 Systems or 1.0 <br />Water heater heated by ground source heat pump meeting requirements of Option 3.3. <br />To qualify to claim this credit, the building permit drawings shall specify the option being <br />selected and shall specify the water heater equipment type and the minimum equipment <br />efficiency and, for solar water heating systems, the calculation of minimum energy savings. <br />Water heating system shall include one of the following: <br />Electric heat pump water heater meeting the standards for Tier I of NEEA's advanced water <br />heating specification or <br />5.4 For R-2 Occupancy, electric heat pump water heater(s), meeting the standards for Tier I of 1.5 <br />NEEA's advanced water heating specification, shall supply domestic hot water to all units. If <br />one water heater is serving more than one dwelling unit, all hot water supply and <br />recirculation piping shall be insulated with R-8 minimum pipe insulation. s <br />Water heating system shall include one of the following: Electric heat pump water heater <br />meeting the standards for Tier III of NEEA's advanced water heating specification or <br />5.5 For R-2 Occupancy, electric heat pump water heater(s), meeting the standards for Tier III of 2.0 <br />NEEA's advanced water heating specification, shall supply domestic hot water to all units. If <br />one water heater is serving more than one dwelling unit, all hot water supply and <br />recirculation piping shall be insulated with R-8 minimum pipe insulation. 5 <br />611 <br />Water heating system shall include one of the following: <br />Electric heat pump water heater with a minimum UEF of 2.9 and utilizing a split system <br />configuration with the air -to -refrigerant heat exchanger located outdoors. Equipment shall <br />meet Section 4, requirements for all units, of the NEEA standard Advanced Water Heating <br />Specification with the UEF noted above or <br />For R-2 Occupancy, electric heat pump water heater(s), meeting the standards for Tier III of <br />NEEA's advanced water heating specification and utilizing a split system configuration with <br />the air -to -refrigerant heat exchanger located outdoors, shall supply domestic hot water to all <br />units. If one water heater is serving more than one dwelling unit, all hot water supply and <br />recirculation piping shall be insulated with R-8 minimum pipe insulation. s <br />5 To qualify to claim this credit, the building permit drawings shall specify the option being selected and shall <br />specify the water heater equipment type and the minimum equipment efficiency. <br />2.5 <br />Prescriptive Path - Single Family 2018 Washington State Energy Code-R <br />
The URL can be used to link to this page
Your browser does not support the video tag.