ELECTRICAL GENERAL NOTES <br /> LUMINAIRE SCHEDULE Ak <br /> A.ANY EXISTING CONDITIONS INDICATED IN THIS SET OF DRAWINGS ARE BASED ON <br /> LAMP LAMP SELECTED INFORMATION PROVIDED BY OTHERS AND POSSIBLE LIMITED FIELD VERIFICATION. <br /> MARK MANUFACTURER CATALOG NUMBER VOLTAGE WATTS MOUNTING DESCRIPTION TYPE BY OTHERS? REMARKS ADJUST FOR ACTUAL FIELD CONDITIONS AT NO ADDITIONAL EXPENSE TO THE <br /> OWNER. � <br /> 11154 LITHONIA LIGHTING 2BLT2 2X2BLT-33L-ADP-LP830 120 277 27 W WALL, SURFACE INTEGRAL LED YES COORDINATE ORDERING WITH ARCHITECT. B.VISIT THE PROJECT SITE,REVIEW EXISTING CONDITIONS AGAINST THE CONTRACT <br /> 11427 JUNO R552WH 120 75 W TRACK 75W PAR30 LED YES WHITE TRACK HEAD DOCUMENTS,AND BECOME FAMILIAR WITH THE WORK PRIOR TO BIDDING AND START <br /> 12946 JUNO TRACK SECTION: R4BL JOINER: R38BL MINI END FEED: RCLFM11BL 120 - TRACK - YES 4' BLACK TRACK SECTION NTH JOINER AND MINI END FEED OF WORK.SIGNING THE CONTRACT IS AN ACKNOWLEDGMENT THAT THE SITE VISIT <br /> 15057 LITHONIA 2BLT4-40L-ADP-EZ7-LP 830 120 34 W CEILING, RECESSED INTEGRAL LED YES 2X4 LOW-PROFILE RECESSED LUMINAIRE- 0-10V DIMMABLE HAS BEEN COMPLETED AND THE EXISTING CONDITIONS ARE ACCEPTED. <br /> 15057EMI LITHONIA 2BLT4-40L-ADP-EZ7-LP830-E1oWLCP 120 34 W CEILING, RECESSED INTEGRAL LED YES 90 MINUTE BATTERY BACKUP C.DEMOLISH ANY EXISTING EQUIPMENT,DEVICES,AND LUMINAIRES ASINDICATED <br /> 20683 FEISS KP1001MBK 120 5 W CEILING, SUSPENDED G9 T4 5W LEDs LED YES AND/OR AS REQUIRED TO ALLOW FOR INSTALLATION AND CONSTRUCTION OF THE <br /> NEW WORK.REMOVE ALL EQUIPMENT,DEVICES,LUMINAIRES,CONDUITS, <br /> 20748 DOLAN HOSPITALITY ZVL47321-CH-2700K 120 17 W WALL, SURFACE INTEGRAL LED YES SUPPORTS,HANGERS,ETC.THAT ARE NOT SHOWN AND ARE REQUIRED TO BE ©zaza sraseucXs carrsEc°unvry <br /> 21177272 ALPHABET NU3-RA-SW-I3LM-27K-90-S35-120-DIM10-NC-WH-WH 120 12 W CEILING, RECESSED INTEGRAL LED YES REMOVED IN ORDER TO COMPLETE THE NEW WORK. <br /> 21772EM ALPHABET NU3-RA-SW-I3LM-27K-90-S35-120-DIM10-NC-NM-WH-EM72 120 1 12 W CEILING, RECESSED INTEGRAL LED YES D.ELECTRICAL CIRCUITS THAT ARE TO BE REMOVED SHALL BE REMOVED IN THEIR S TA R B U C K 5® <br /> 21774 ALPHABET NU3-RA-SW-1OLM-27K-9D-D60- 120-DIM10-NC-WH-WH 120 1 9 W CEILING, RECESSED INTEGRAL LED YES ENTIRETY,CONDUCTORS SHALL BE REMOVED FROM THE ITEM TO BE DEMOLISHED 2835 N MCCARRAN BLVD#103 <br /> 22215 CS ILLUMINATION LL91STP-MO-27K-SL-SL 24 4W WALL,CEIUNG,SURFACE INTEGRAL LED YES TO THE SOURCE OVERCURRENT DEVICE.RACEWAYS WHICH ARE INSTALLED IN OR SPARKS,NEVADA 89431 <br /> 22249 ALPHABET NU3-RD-SW-I3LM-30K-90-HE50-UNV-DIMIO-NC-WH-WH 120 12 W CEILING, RECESSED INTEGRAL LED YES BELOW FLOORS OR WITHIN WALLS MAYBE ABANDONED,BUT ALL OVERHEAD OR 775 331-8551 <br /> EXPOSED RACEWAYS SHALL BE REMOVED.EXPOSED RACEWAYS TO BE <br /> 22249EM ALPHABET NU3-RD-SW-I3LM-3OK-90-HE50-UNIDI.10-NC-WH-WH-EM12 120 12 W CEILING, RECESSED INTEGRAL LED YES 90 MINUTES AT 12W BATTERY BACKUP ABANDONED SHALL BE REMOVED AND SHALL BE CUT OR CHISELED AT LEAST 2" <br /> X2305 SCHOOLHOUSE ELEC. ANNETTE SCONCE 120 200 W WALL, SURFACE G25 MEDIUM BASE LED YES ICOORDINATE FINISH WITH ARCHITECT INTO THE WALL OR FLOOR AND THE OPENING GROUTED SMOOTH. THESE DRAWINGS AND THE PROJECT MANUAL <br /> ARE CONFIDENTIAL AND SHALL REMAIN THE <br /> LUMINAIRE SCHEDULE GENERAL NOTES: <br /> E.MAINTAIN CONTINUITY OF EXISTING CIRCUITS AS REQUIREDTO PROVIDE POWER SOLE PROPERTY OF STARBUCKS <br /> TO REMAINING EQUIPMENT,DEVICES AND LUMINAIRS THATARE NOT BEING CORPORATION,WHICH IS THE OWNER OF THE <br /> A. LUMINAIRE SYMBOLS THAT ARE LABELED "EM" ON THE PLAN(S) INDICATE LUMINAIRES THAT SERVE AS EMERGENCY LIGHTING. PROVIDE EMERGENCY ILLUMINATION FOR A MINIMUM OF 90 MINUTES. REMOVED. COPYRIGHT IN THIS WORK.THEY SHALL NOT <br /> B. ANY PROPOSED SUBSTITUTIONS FOR LUMINAIRES THAT ARE SELECTED BY OTHERS REQUIRE THE APPROVAL OF THE SPECIFYING ENTITY. BE REPRODUCED(IN WHOLE OR IN PART), <br /> F.WHERE THE MECHANICAL DESIGN UTILIZES A PLENUM RETURN AIR CEILING SHARED WITH THIRD PARTIES OR USED IN ANY <br /> DESIGN,ALL EQUIPMENT AND MATERIALS INSTALLED WITHIN THE PLENUM RETURN MANNER ON OTHER PROJECTS OR <br /> CEILING MUST MEET THE FLAME SPREAD AND SMOKE DEVELOPED RATINGS OF EXTENSIONS TO THIS PROJECT WITHOUT THE <br /> 25/50 AND BE APPROVED FOR USE IN PLENUM RETURN CEILINGS.COORDINATE PRIOR WRITTEN CONSENT OF STARBUCKS <br /> PLENUM CEILING LOCATIONS WITH THE MECHANICAL CONTRACTOR. CORPORATION.THESE DRAWINGS AND <br /> ELECTRICAL PLAN NOTES <br /> THAT ARE MANUFACTURED WITH A METAL HOUSING MEET THIS REQUIREMENT AND SPECIFICATIONS ARE INTENDED TO EXPRESS <br /> SWITCHBANK "SB" SCHEDULE 1❑ PROVIDE LIGHTING CONTROL SWITCHBANK.SEE SWITCHBANK SCHEDULE FOR ARE NOT REQUIRED TO BE PLENUM RATED UNLESS INDICATED OTHERWISE. DESIGN INTENT FOR A PROTOTYPICAL <br /> SWITCH TAG ZONE DESCRIPTION CONTROL TYPE ADDITIONAL INFORMATION.LOWERCASE LETTERS ADJACENT TO THE LUMINAIRES G.SEE PANEL SCHEDULES FOR INFORMATION ON CIRCUITS THATARE TO BE ROUTED STARBUCKS STORE(WHICH IS SUBJECT TO <br /> a WORKROOM UGHTS 3-WAY TOGGLE SNITCH ON PLANS CORRESPOND TO THE ASSOCIATED SWITCH ON THE SWITCHBANK CHANGE AT ANYTIME)AND DO NOT REFLECT <br /> SCHEDULE.CONFIRM SWITCHBANK WILL FIT WITHIN THIS DESIGNATED AREA AND THROUGH CONTACTORS OR RELAYS FOR CONTROL. ACTUAL SITE CONDITIONS.NEITHER PARTY <br /> b ENGINE LIGHTS UNE VOLTAGE DIMMER STACK MULTIPLE SWITCHBANKS,WITH FEWER GANGS,AT THIS LOCATION IF H.PRESERVE THE FIRE RATING OF ANY FIRE-RATED CEILING ASSEMBLIES BY SHALL HAVE ANY OBLIGATION NOR LIABILITY TO <br /> CAFE DOWNUGHTS UNE VOLTAGE DIMMER SINGLE SWITCHBANK WILL NOT FIT WITHIN THIS DESIGNATED AREA. PROVIDING THE APPROPRIATE FIRE-RATED LUMINAIRE TENTS AS MANUFACTURED THE OTHER(EXCEPT STATED ABOVE)UNTIL <br /> d CAFE ACCENT LIGHTS SPST TOGGLE SWITCH BY TENANT OR NELSON FIRESTOP OR BY BUILDING FIRE-RATED ENCLOSURES WRITTEN AGREEMENT IS FULLY EXECUTED BY <br /> e RESTROOM VESTIBULE UGHTS I LINE VOLTAGE DIMMER ❑2 INSTALL THIS LUMINAIRES REMOTE LOW VOLTAGE LIGHTING POWER SUPPLY/ AROUND EACH LUMINAIRE THAT IS RECESSED INTO THE FIRE-RATED ASSEMBLY. I BOTH PARTIES, <br /> TRANSFORMER(RPS)IN AN INCONSPICUOUS,ACCESSIBLE LOCATION AND COORDINATE FIRE-RATED CEILING ASSEMBLY LOCATIONS WITH THE <br /> GENERAL NOTES: PROVIDE FINAL CONNECTION TO LUMINAIRE.COORDINATE MOUNTING LOCATION ARCHITECTURAL DRAWINGS. F STARBUCKS TEMPLATE VERSION:i2023.0424 <br /> A. PROVIDE BOX PARTITIONS BETWEEN CONTROLS OF DIFFERING VOLTAGES. OF RPS WITH OWNER PRIOR TO ROUGH-IN.THE LENGTH OF CONDUCTORS <br /> BETWEEN RPS AND ASSOCIATED LUMINAIRE SHALL NOTE EXCEED I. ALL LUGS,TERMINALS,ETC.IN ELECTRICAL DISTRIBUTION EQUIPMENT SHALL BE <br /> MANUFACTURER'S RECOMMENDATIONS FOR MAXIMUM CONDUCTOR LENGTH.RPS LISTED FOR A MINIMUM OF 75 DEGREE C CONDITIONS.TERMINATIONS LISTED FOR ARCHITECT OF RECORD <br /> DESIGNATIONS INDICATED ADJACENT TO LUMINAIRES CORRESPOND TO THE ONLY 60 DEGREE C CONDUCTORS ARE NOT PERMITTED. <br /> ASSOCIATED RPS SUPPLYING THE LUMINAIRE. J.CIRCUITS SERVING EMERGENCY LIGHTING EQUIPMENTSUCH AS EMERGENCY <br /> 3� COVE LIGHT LOCATED UNDER COUNTER. BATTERIES SHALL NOTSHAREA NEUTRAL(SHALL NOT BE PART OFA MULTWIRE <br /> BRANCH CIRCUIT)WITH ANY OTHER CIRCUIT.PROVIDE A SEPARATE NEUTRAL FOR <br /> EVERY CIRCUIT THAT SERVES EMERGENCY LIGHTING. <br /> K.ALTHOUGH NOT SPECIFICALLY SHOWN,THE ELECTRICAL CONTRACTOR SHALL GRAPHITE DESIGN GROUP,LLC,ARCHITECTS <br /> PROVIDE ALL REQUIRED LOW VOLTAGE WIRING AND DATA CABLING,INCLUDING 1807 7TH AVENUE,SUITE 700 <br /> ALL 0-10V CONTROL WIRING WHERE APPLICABLE,PERTHE MANUFACTURER'S SEATTLE,WA 98101 <br /> RECOMMENDATIONS,FOR A COMPLETE,FUNCTIONAL LIGHTING CONTROL (206)724-3335 <br /> SYSTEM, <br /> L.LUMINAIRES MARKED"EX"ARE EXISTING LUMINAIRES THAT ARE TO REMAIN IN <br /> PLACE.ALL EXISTING LUMINAIRES WITHIN THE LIMITS OF CONSTRUCTION SHALL y RpY Sr <br /> BE REPAIRED TO A LIKE-NEW CONDITION,THOROUGHLY CLEANED,AND � tit <br /> RELAMPED.ANY EXISTING LUMINAIRES THAT ARE DAMAGED BEYOND REPAIR <br /> II II II II SHALL BE REPLACED WITH AN IDENTICAL LUMINAIRE. ti <br /> II 11 II 11 M.LUMINAIRES MARKED"RR"ARE EXISTING LUMINAIRES THATARE TO BE OR HAVE x rm- <br /> I� BEEN RELOCATED.ALL LUMINAIRES DESIGNATED FOR RELOCATION SHALL BE <br /> II \ IL-- _ -- i II DISCONNECTED FROM EXISTING BRANCH CIRCUIT,REMOVED FROM EXISTINGs <br /> _____________ ___ ___ _______ AREA,STORED,REPAIRED TO A LIKE-NEW CONDITION,INSTALLED IN REMODELED <br /> __ ___ _ __ ____ �1 <br /> I� r AREA,RECONNECTED,THOROUGHLY CLEANED,AND RELAMPED.ANY RELOCATED <br /> II I I II LUMINAIRES THAT ARE DAMAGED BEYOND REPIAR SHALL BE REPLACED WITH AN ONAL o sa <br /> II EX 3 II IDENTICAL LUMINAIRE. <br /> II I I I II <br /> EX L_ EM 3e _J EX <br /> 30e 3c EX <br /> 30e <br /> EX <br /> 11154 i <br /> 1 L 22249EM L 22249(8) 3d 3. 3c 3d <br /> II <br /> 9-30,17)E _ _ ______________ ____ L12948 7 EX EX <br /> O E% L X2305(2) (2)L 11427 r <br /> a EX <br /> L 20748 W. 30e 3c L 21774(4) (4)L 21774 3c ~ L N <br /> D 0 Co <br /> 0)3c 3c 3c 3. 1 <br /> EXIS77NG PANEL B- 1 1 1 E7M 3c EM 3c I RR W Q <br /> L 22249EM L 22249(5) 1 O <br /> r =1 B 3c 3c i RR Ex 'QI <br /> 1 1b I I I 3d 3c 1b 1b 1b 1b 1 b 1b 1b 1b 1b ib 1b RR RR W IL— <br /> EX E E I I I I 7° 1a 1° PSCO <br /> OS 3d ® 3d 3d 1Lii p I- <br /> 2 60W 3d G 03d L 20683(3) 60W L 22215 3 3c I Z Q Z W <br /> d C 0 I <br /> L 1 57E 15057(8) - 3d ib tb I 1 U O U o W <br /> �__ ________ 21772(28r_ ___ ___ ___ OL O O > <br /> 21nz€M ———— <br /> 2 16 16 1b 1b 1b 1b 1b EM b 1b 1b 1b 1b lb 1b I I EL CoW a- r LLI <br /> 2 96W L 22215 I STORE M 22817 <br /> _ PS02 I <br /> -3d--_ PROJECT#: 60007-039 <br /> 2 T <br /> 2 4 �17A EX E% ISSUE DATE: 10.2.2023 <br /> L 22215 L 22215 6OW 96W L 22215 DESIGN MANAGER: GRAPHITE <br /> _3d Pso --- -- P50 3d -- --_ 3d-_ PRODUCTION DESIGNER: GRAPHITE <br /> __ CHECKED BY: <br /> ILI <br /> r-- <br /> 11 II II II Revision Schedule <br /> 1b lb <br /> II I I I 8 Date Description <br /> THESE DOCUMENTS HAVE NOT BEEN 3/1Bno2a REV 1:HVAC REDESIGN <br /> L 21772(2) if APPROVED FOR THE ISSUANCE OF <br /> PUBLIC WORK,MECHANICAL,FIRE <br /> 11 II SUPPRESSION,ELECTRICAL OR <br /> PLUMBING PERMITS <br /> I i II 11 II �I SHEET TITLE: <br /> LIGHTING PLAN <br /> n u n <br /> g L—=—�--=ll=--===IL====J LEGEND SCALE:AssTlowN <br /> A LIGHTING PLAN N ExisnroGI SHEET NUMBER: <br /> 0 1 s��: 1/4"=I,T —NEW WDRK <br /> wo <br /> „ ® NEW 7O ES77NO CCWNEC77ON �' <br /> Y/ E 103 <br />