1010 N BROADWAY 2023 STARBUCKS Plans 2025-06-30
>
Address Records
>
N BROADWAY
>
1010
>
STARBUCKS
>
Plans
>
1010 N BROADWAY 2023 STARBUCKS Plans 2025-06-30
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2025 1:12:03 PM
Creation date
5/7/2025 8:18:57 AM
Metadata
Fields
Template:
Address Document
Street Name
N BROADWAY
Street Number
1010
Tenant Name
STARBUCKS
Permit
B2311-026
Year
2023
Notes
TI EXISTING STARBUCKS CAFE, PARTITIONS, EQUIPT RELOCATION
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
60
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICAL GENERAL NOTES <br /> .. <br /> A. ELECTRICAL CONTRACTOR-COORDINATE WITH PLUMBING AND LOW VOLTAGE <br /> TRADES FOR SPACE LAYOUT.ASSURE SPACE FOR WALL MOUNTED EQUIPMENT, <br /> PLUMBING AND DATA BOXES ARE WELL PLANNED FOR INSTALL _ <br /> Z' <br /> DUPLEX BACK WALL <br /> RECEPTACLE AND <br /> DATA PORT AT 47' <br /> (1190MM)A.F.F. ©�� 9TNiBUCI� ¢ <br /> DEDICATED 111/2" 8" RECEPTACLE FOR <br /> RECEPTACLE FOR (240MM) 200MM REFRIGERATOR STARBUCKS" <br /> INSTANT HOT AND/OR FREEZER 2835 N MCCARRAN BLVD#103 <br /> WATER BOILER AT AT 84"(2135MM) <br /> 26'(660MM)A.F.F. AFF SPARKS,NEVADA 89431 <br /> (775)331 8551 <br /> 11 THESE DRAWINGS AND THE PROJECT MANUAL <br /> rT ARE CONFIDENTIAL AND SHALL REMAIN HE <br /> \ SOLE PROPERTY OF STARBUCKS <br /> / \ POWER RECEPTACLES CORPORATION,WHICH IS AT 28"(711MM)TO TOP COP YR RIGHT IN THIS WORK.THEY SHALL NOT <br /> \� I 18'X 3'(457MM X 78MM) OF RECEPTACLE A.F.F. (IN WHOLE OR IN PART), <br /> BE REPRODUCED <br /> - --- -------- 1'•0" "DEDICATED RECEPTACLE SHARED WITH THIRD PARTIES OR USED IN ANY <br /> I STUB-UP PENETRATION FOR UPS(POS AND PED) MANNER ON OTHER PROJECTS OR <br /> SHELVING ABOVE I i I AREA.SUPPLY POWER EXTENSIONS TO THIS PROJECT WITHOUT THE <br /> i •2-DATA PORT FOR POS, <br /> DATA AND PHONE r , PED AND/OR CONNECT PRIOR WRITTEN CONSENT OF STARBUCKS <br /> CONDUITS FOR POS. f#®I ®I DEVICES <br /> SEE BUILDING FLOOR L__? _ ?J SPECIFICATIONS <br /> ARE HESENDRA IN EXPRESS <br /> PENETRATION PLAN <br /> nWATER FILLING STATION REFRIGERATOR/FREEZER FOR FINAL LOCATION. ____ _ POWER RECEPTACLES DESIGN INTENT FOR A PROTOTYPICAL <br /> AT 28"(711MM)TO TOP STARBUCKS STORE(WHICH IS SUBJECT TO <br /> J ---------)-- -- ---- CHANGE AT ANYTIME)AND DO NOT REFLECT <br /> `t OF RECEPTACLE A.F.F. <br /> lJ sm.3I4'=1'-0" QUAD TUBE USE ACTUAL SITE CONDITIONS.NEITHER PARTY <br /> --------y SHALL HAVE ANY OBLIGATION NOR LIABILITY TO <br /> r - FOR FUTURE USE <br /> +-L--- -- THE OTHER(EXCEPT STATED ABOVE)UNTIL A <br /> -- ---� •2-0A7A PORT FOR WRITTEN AGREEMENT IS FULLY EXECUTED BY <br /> FUTURE USE BOTH PARTIES. <br /> I O <br /> I I I STARBUCKS TEMPLATE VERSION:023.0424 <br /> I II <br /> EDGE OF ARCHITECT OF RECORD <br /> FUTURE HHOP CABLING TO HEADSET BASE I COUNTERTOP <br /> STATION FROM J•BOX AT CLGNVALL FOR SAFE RCOUNTER I IL------ <br /> 1'-912' 38"W X 51"H{915MM W X 1295MM H)MIN.FIRE BOX BASE(BELOW) <br /> EXTERNAL EXTENDED COVERAGE ANTENNA RATED PLYWOOD BACKER BOARD.FASTEN TO -------JL------- - <br /> (FOIO) -__I—-IIII_ STRUCTURE.WALL FINISH TO CONCEAL. , <br /> EDGE OF CABINET <br /> DRIVE THRU WIRELESS HEADSET i I ILII I I DRIVE THRU TIMER SIGNAL PROCESSOR(TSP) cwurenncnaexanK°eras SHELVING(BELOW) GRAPHITE DESIGN GROUP,LLC,ARCHITECTS <br /> BASE STATION <br /> 1807 7TH AVENUE,SUITE 700 <br /> DRIVE THRU TIMER CONTROL UNIT <br /> DRIVE THRU TIMER MONITOR o0'o O o i - I' EPOS 05-01 (267224E-333598101 <br /> LppLp Lp ILo ❑NI I~POWER AND DATA RECEPTACLES AT 8'-2" rT <br /> (2480MM}TO TOP OF RECEPTACLES A.F.F. G _ <br /> LJ L__JI -DEDICATED QUAD RECEPTACLE FOR DRIVE esk 3/4"-i-0' <br /> II II THRUTIMER MONITOR AND CONTROL UNIT <br /> I "(2)DEDICATED DUPLEX RECEPTACLE FOR ROY S <br /> NOTE: EQUIPMENT SHOWN AS '� Cyn <br /> DASHED LINES IS TO BE i I I i WIRELESS BASE AND SIGNAL PROCESSOR <br /> FURNISHED AND INSTALLED �L___-�I WITH CIRCUIT ISOLATED GROUND <br /> BY OWNER UNLESS NOTED _ - I "2-DATA PORT FOR DT TIMER AND CONTROL UNIT } 'F <br /> OTHERWISE I ^SINGLE DATA PORT FOR DT AUDIO m rm- <br /> (MIG 8 SPEAKER) qfs o 00o THESE DOCUMENTS HAVE NOT BEEN <br /> DRIVE THRU DIGITAL I III I I ® APPROVED FOR THE ISSUANCE OF ONAL <br /> Fr_---1 - PUBLIC WORK,MECHANICAL,FIRE <br /> aom <br /> PRODUCTION MONITOR I III RECEIPT PRINTER SUPPRESSION,ELECTRICAL OR caa ro#Zyoy/as/v <br /> ' PLUMBING PERMITS <br /> L-- ==--J DRIVE THRU TENDERING REGISTER DUPLEX CONVENIENCE <br /> OUTLET AT 45'1143MM TO <br /> TOP OF RECEPTACLE A.F.F. <br /> TRIPLE MONITOR MOUNT(GC INSTALLED) I I I I I I I POWER AND DATA <br /> POWER AND DATA <br /> SEE PLAN VIEW FOR MOUNTING LOCATION I I I I I I DRIVE THRU EXPEDITOR POS RECEPTACLES AT 18" RECEPTACLES AT 26" <br /> L--_ (457MM)TO TOP OF (711MM)TO TOP OF <br /> POWTOP RECEPTACLE A.F.F.ER RECEPTACLES A7 26"(717 MM)TO �o POWER RECEPTACLE AT RECEPTACLE A.F.F. RECEPTACLE A.F.F. <br /> .DEDICATED QUAD RECEPTACLE FOR DT i <br /> DIGITAL PRODUCTION MONITOR UPS UNIT r-7 RECEPTACLE A.F.F. T f <br /> (FOR DRIVE THRU TENDERING REGISTER) -QUAD RECEPTACLE FOR <br /> 6 AND FUTURE USE UNDERCOUNTER <br /> -DEDICATED QU FUTURE USE 00 <br /> AD RECEPTACLE FOR i� REFRIGERATORAND \ �� 1� Q N <br /> v FUTURE USE OIII II°II°❑ -(r-i� Oo' <br /> 00°00 0�❑❑ T <br /> •2-DATA PORT FOR TENDERING REGISTER --_-- �- /Ip °I\ <br /> SINGLE DOOR O ❑ Q <br /> AND EXPEDITOR POS =� F= '�j REFRIGERATOR �� N <br /> "4-0ATA PORT FOR DT VIDEO AND FUTURE > II IQ :: O <br /> 06 <br /> USE DT AUDIO CONDUIT FROM <br /> DRIVE THRU ORDER POINT <br /> POS BANK(TYP) AND DETECTOR LOOP 0 <br /> CONDUIT FROM DT W ' M CASH DRAWERS WINDOW TO DT TIMER W Co L <br /> CONTROL DATA JUNCTION 2 O r <br /> BOXES AT 8'-2"(2490MM) Z pQ 7 W <br /> DRIVE THRU VIDEO CONDUIT FROM OT ORDER POINT TO ELEVATION-ELECTRICAL DIAGRAM L <br /> DT VIDEO DATA BOX AT 28"(711MM)A.F.F. U O U <br /> ELEVATION VIEW ' �/ LU r \ <br /> POWER AND DATA O LL O <br /> RECEPTACLES AT 18" POWER AND DATA D_ Coof O / <br /> "DIMENSIONS INDICATE CENTER 710" (457MM)TOTOPOF RECEPTACLES IL Q_ T_ W <br /> MOUNTING POINT FOR MONITOR BASE RECEPTACLE A.F.F. RECEPTACLE <br /> TOP OF <br /> 1'-3' 1'-10" 8' 9 ill' 8'-8' RECEPTACLE A.F.F. <br /> •RECEPTACLE FOR -RECEPTACLE FOR STORE M 22817 <br /> POWER AND DATA RECEPTACLES POWER RECEPTACLE COMBIOVEN 1'4" T-11" T-3" UNDERCOUNTER <br /> ^DEDICATED QUAD RECEPTACLE FOR DT PROJECT#: 60007-039 <br /> •QUADRECEPTACLE •OVEN PORT COMBI REFRIGERATOR <br /> DIGITAL PRODUCTION MONITOR UPS UNIT I FOR IGERATO AND OVEN -RECEPTACLE FOR ISSUE DATE: 10.2.2023 <br /> (FOR DRIVE THRU TENDERING REGISTER) REFRIGERATORAND <br /> --------- LABEL PRINTER <br /> AND FUTURE USE �v�4 � f FUTURE USE O \ 2 AND FUTURE USE DESIGN MANAGER: GRAPHITE <br /> EDICATED QUAD RECEPTACLE FOR I I I PRODUCTION DESIGNER: GRAPHITE <br /> FUTURE USE '7W�2�y <br /> 1 O •2-DATA PORT FOR CHECKED BY' <br /> �i POWER RECEPTACLE LABEL PRINTER <br /> •2-DATA J-BOX \�y I I -DUPLEX CONVENIENCE <br /> "4-DATA ND D - <br /> _ ��_,]]}I-{r''}}��'''�YIIw I I Revision Schedule <br /> POWER AND DATA RECEPTACLES 2u UNOERCOUNTER 4" 4' I I <br /> --�� - _ <br /> •DEDICATED QUAD RECEPTACLE FOR DRIVE �[ REFRIGERATOR I I Date B Description <br /> THRU TIMER MONITOR AND CONTROL UNIT- Ir-----7 ff==---� I I 3NBI2024 REV I:HVAC REDESIGN <br /> 12)DEDICATEDDUPLEXRECEPTACLEFOR L==—__J — —=__=J I <br /> WIRELESS BASE AND SIGNAL PROCESSOR I I <br /> WITH CIRCUIT ISOLATED GROUND I EDGE OF COUNTERTOP I <br /> •2-DATA J-BOX <br /> •SINGLE DATA J-BOX Li <br /> PLAN VIEW FOR LICENSED STORES PROJECTS,FUTURE USE POWER RECEPTACLES �nar��c�ewonK OErar ELEVATION-ELECTRICAL DIAGRAM SHEET TITLE: <br /> AND DATA PORTS ARE TO BE USED FOR STARBUCKS CONNECT DEVICES <br /> `�'"������`°�`"�` ELECTRICAL DETAILS <br /> 3 POS 08-03 WRM 19-01 SCALE:AS SHOWN <br /> 3/4"=V-0" C�M„y„ ' SHEET NUMBER: <br /> e ` "�' E502 <br />