EXISTING PANEL "B" EXISTING PANEL "A" <br /> FED FROM: PANEL"A" MOUNTING: FLUSH MOUNTED FED FROM: UTILITY TRANSFORMER MOUNTING: FLUSH MOUNTED <br /> VOLTAGE: 208Y/12OV.3 PHASE,4 WIRE ENCLOSURE: NEMA 1 VOLTAGE: 20BY/12OV, 3 PHASE,4 WIRE ENCLOSURE: NEMA 1 = <br /> BUS MATERIAL: EXISTING FAULT CURRENT: EXISTING BUS MATERIAL: EXISTING FAULT CURRENT: EXISTING <br /> BUS LOAD: 137 AMPS AIC/SCCR RATNG: MATCH EXISTING BUS LOAD: 353 AMPS AIC/SCCR RATING: MATCH EXISTING <br /> : <br /> BUS RATING: 4GO AMPS OPTIONS*: BONDED EQUIPMENT GROUND BAR BUS RATING: 400 AMPS OPTIONS*: BONDED EQUIPMENT GROUND BAR <br /> MAINMAIN LUG ONLY MAIN: 400/3 MAIN BREAKER <br /> LOAD(VA) LOAD(VA) LOAD(VA) LOAD(VA) <br /> NOTES CKT. LOAD DESCRIPTION A B C BREAKER BREAKER A B C LOAD DESCRIPTION CKT. NOTES NOTES CKT. LOAD DESCRIPTION I A B C IBREAKERIBREAKER A I B C I LOAD DESCRIPTION CKT. NOTES <br /> C-1 1 WORKROOAI/BAR UGHTS 1643 20/1 20/1 300 EXTERIOR SIGNS 2 C-3 1 RTU-1 7176 70/3 20/2 1144 ICE MAKER,HEAD 2 GFCI <br /> C-2 3 CAFE UCHTS 250 20/1 20/1 200 MENU BOARD 4 C-3 3 ----- 7176 --- --- 1144 4 ©zazz sTnRsucKs-FEE COMPANY <br /> ____ <br /> 5 20/1 200 DT SIGNS 5 C-3 5 ----- 7176 1 --- 20/1 460 UC REFRIGE. 6 GFCI <br /> 7 ASHP-1 2212 40/2 40/3 2333 WATER HEALER 8 7 --2 7176 70/3 20/1 1500 INSTAHOT 8 GFCI �`T /V /C"'� <br /> 9 --- 221 --- --- 10 9 ----- 7176 --- 20/1 460 UC REFRIGE. 10 GFCI S /-1 LJ K J <br /> HPL 11 --- 2333 ---- 12 11 ----- 7176 --- 20/1 1500 INSTAHOT 12 GFCI 2835 N MCCARRAN BLVD#103 <br /> --- 20/1 Ih!II ^""1:^u!!9ULLOING LIGHTS'. 14 C-3 GFCI 13 WATER FILLING STATION 1300 20/1 20/1 540 SEATING RECEPTS. 14 SPARKS,NEVADA 89431 <br /> GFCI 15 DIGITAL MENU BOARD 360 20/1 20/ 708 AHU-1 6 GFCI 15 WATER FLUNG STATION 180 20/1 20/1 SPARE 16 (775)331-8551 <br /> GFCI 17 REACH-IN REFRIG. 1000 20/1 ---„ 708 ----- iB GFCI 17 ESPRESSO 2975 40/2 20/1 100 RAIN BIRD 18 <br /> GFCI 19 REACH-IN REFRIG. 1000 20/1 20/2•"' '400 - -;'' 2C C-4 19 ----- 2975 --- 20/1 100 SPEAKER POST 20 THESE DRAWINGS AND THE PROJECT MANUAL <br /> GFCI 21 MANAGER'_DESK 720 20/1 --- 400 ----- 22 GFCI 21 ESPRESSO 2975 40/2 20/1 1500 RR HAND DRYER 22 HPL ARE CONFIDENTIAL AND SHALL REMAIN THE <br /> GFCI 23 MANAGER'S DESK 960 20/1 20/1 100 LIGHTING CONTROL PANEL 24 23 ----- 2975 --- 20 1 900 IT RACK 24 GFCI SOLE PROPERTY OF STARBUCKS <br /> / CORPORATION,WHICH IS THE OWNER OF THE <br /> GFCI 25 MILK/ICE DISPENSER 1800 20/1 20/1 1000 REACH-IN REFRIGE. 26 GFCI 25 ROOF RECEPT. 360 20/1 15/1 568 REDRC.PUMP,P-1 26 C-1 COPYRIGHT IN THIS WORK.THEY SHALL NOT <br /> GFCI 27 GRINDER 1800 20/1 20/1 1000 REACH-IN REFRIGE. 28 27 DUCT SMOKE DETECTOR 100 20/1 20/1 180 ICE MAKER,DIMORTER 28 GFCI BE REPRODUCED(IN WHOLE OR IN PART), <br /> GFCI 29 UC REFRIGE. 460 20/1 20/1 90 RR AND VESTIB.EM UGHTS 30 FCl/C-1 GFCI 29 PARTNER AREA MICROWAVE 1200 20/1 20/1 460 UC REFRIGE 30 GFCI SNARED WITH THIRD PARTIES OR USED IN ANY <br /> MANNER ON OTHER PROJECTS OR <br /> GFCI 31 OVEN 3000 30/2 20/1 720 DT POS 32 GFCI GFCI 31 DT WINDOW 300 2, 20/1 SPARE 32 EXTENSIONS TO THIS PROJECT WITHOUT THE <br /> 33 ----- 3000 --- 20/1 SPARE 34 GFCI GFCI 33 NITRO DISPENSER 12DO 20/1 30/2 2984 WARMING WALL 34 GFCI PRIOR WRITTEN CONSENTOF STARBUCKS <br /> GFq 35 OVEN 3000 30/2 201/1 720 DT POE 36 GFCI GFCI 35 NITRO GENERATOR 720 20/1 2984 36 CORPORATION.THESE DRAWINGS AND <br /> 37 ----- 3000 --- 20/1 640 DT UC REFRIGE. 38 GFCI GFCI 37 REACH-IN FREUER 660 20/1 30/3 2831 COM I-OVEN 38 GFq SPECIFICATIONS ARE INTENDED TO EXPRESS <br /> HPL 39 SANrnzER 3120 40/2 50/2 4160 BREWER 40 GFCI GFCI 39 POS 540 20/1 --- 2831 __—_ 40 DESIGN INTENT FOR A PROTOTYPICAL <br /> STARBUCKS STORE(WHICH IS SUBJECT TO <br /> SPARE 20/1 --- 2831 ---- 42 CHANGE AT ANYTIME)AND DO NOT REFLECT <br /> FEED-THROUGH LUGS ACTUAL SITE CONDITIONS,NEITHER PARTY <br /> NOTES: 16342 FTL SUBFEED PANEL E' SHALL HAVE ANY OBLIGATION NOR LIABILITY TO <br /> * SEE SPECIFICATIONS FOR OTHER OPTIONS REQUIRED BUT NOT NECESSARILY NOTED HERE 16267 FTL -___ THE OTHER(EXCEPT STATED ABOVE)UNTIL <br /> GFCI PROVIDE GROUND-FAULT CIRCUIT-INTERRUPTER(GFCI)5 MILLIAMP TRIP TYPE CIRCUIT BREAKER. WRITTEN AGREEMENT IS FULLY EXECUTED BY <br /> HPL PROVIDE PERMANENTLY-INSTALLED HANDLE PADLOCK ACCESSORY TO LOCK CIRCUIT BREAKER IN THE OPEN POSITION. 13704 FTL I BOTH PARTIES, <br /> C-# ROUTE CIRCUIT THROUGH CONTACTOR( =CONTACTOR DESIGNATION). <br /> NOTES: STARBUCKS TEMPLATE VERSION:12023.04.24 <br /> SEE SPECIFICATIONS FOR OTHER OPTIONS REQUIRED BUT NOT NECESSARILY NOTED HERE <br /> LOAD ANALYSIS FOR PANEL "B INCLUDING SUBFEEDS GFCI PROVIDE GROUND—FAULT CIRCUIT—INTERRUPTER(GFCI)5 MILLIAMP TRIP TYPE CIRCUIT BREAKER. <br /> ( ) HPL PROVIDE PERMANENTLY—INSTALLED HANDLE PADLOCK ACCESSORY TO LOCK CIRCUIT BREAKER IN THE OPEN POSITION. ARCHITECT OF RECORD <br /> DEMAND PHASE A(VA) PHASE B(VA) PHASE C(VA) TOTAL(VA) C_# ROUTE CIRCUIT THROUGH CONTACTOR(#=CONTACTOR DESIGNATION). <br /> LOAD DESCRIPTION FACTOR CONNECT.I DEMAND CONNECTI DEMAND CONNECT. DEMAND ICONNECT. DEMAND <br /> LIGHTING: 125% 2543 3179 850 1063 290 363 3683 4604 uw.ruxu .,,ss,,..,s�..,.,A•�u«...e_�„:nx�.,o <br /> RECEPTACLE: 100% 1360 1360 1080 1080 1680 1680 4120 4120 LOAD ANALYSIS FOR PANEL "A" (INCLUDING SUBFEEDS) <br /> OTHER NONCONTINUOUS: 100% 0 0 0 0 100 100 100 100 DEMAND PHASE A(VA) PHASE B(VA) I PHASE C(VA) I TOTAL(VA) GRAPHITE DESIGN GROUP,LLC,ARCHITECTS <br /> WATER HEATING: 100% 2334 2334 2334 2334 2334 2334 7000 7000 LOAD DESCRIPTION FACTOR CONNECT. DEMAND CONNECT. DEMAND CONNECT. GRAPH <br /> DEMAND CONNECT. DEMAND 1807 GRAPHH AVENUE,SUITE 700 <br /> KITCHEN: 65% 10600 6890 13080 8502 12540 8151 36220 23543 LIGHTING: 125% 2543 3179 850 1063 290 1 363 3683 4604 SEATTLE,WA 9B101 <br /> MOTOR: 700% 2212 2212 2920 2920 708 708 5840 5840 RECEPTACLE: 100% 2260 2260 2440 2440 4700 4700 9400 9400 (206)224-3335 <br /> ADD 25%OF LARGEST MOTOR: 100% 369 369 369 369 369 369 1106 1106 OTHER NONCONTINUOUS: 100% 400 400 160C 1600 200 200 2200 2200 <br /> TOTAL 19417 16343 20632 16267 18020 13704 58069 46313 WATER HEATIN2: 100% 2334 2334 2334 2334 2334 2334 7000 7000 <br /> EQUIVALENT AMPS: 162 137 172 136 151 115 162 129 KITCHEN: 65% 21010 13657 24214 15740 26525 17242 71749 46637 <br /> PHASE BALANCE: 5.86% 5.37R -11.23% COOLING ONLY: 100% 14352 14352 14352 14352 14352 14352 43056 43056 O�y �OHNyn <br /> MOTOR: 100% 2780 2780 2920 2920 705 708 6408 6408 ti <br /> ADD 25%OF LARGEST MOTOR: 100% 1 1794 1794 1 1794 1794 1794 1794 5382 5382 y g m <br /> TOTAL: 47472 1 40754 1 50504 42241 50903 41692 148878 124686 <br /> EQUIVALENT AMPS: 396 340 421 353 425 348 414 3471 31 <br /> PHASE BALANCE: -1.94% 1.639. 0.31% of E1+E <br /> ONAL Dora 1012512J <br /> CO {2509 <br /> F- < N <br /> C) j 00 <br /> PAD MOUNT TRANSFORMER 06 >� <br /> BY LOCAL UTILITY COMPANY O <br /> TRANSFORMER PAD Q V) <br /> BY ELECTRICAL <br /> CONTRACTOR LLlLU <br /> PRIMARY CONDUIT <br /> BY ELECTRICAL Z Q Z <br /> CONTRACTOR O <br /> U O L) <br /> N D LU <br /> PRIMARY FEEDERS BY EXISTING 2 SETS OF c i m I \ <br /> LOCAL UTILITY COMPANY 4-250 KCMIL <br /> WITH GROUND A C)O m MM O <br /> EACH SET z ai E m d W d r W <br /> �pzrc <br /> 114'x 4"x 12"COPPER GROUND 0 IN 2 1/2'CONDUIT Z o p; STORE#: 22817 <br /> BAR H7TH WALL MOUN77NG r m x <br /> BRACKE75 AND/NSULA TORS —T m m <br /> LUG AS REQUIRED FOR mn m N PROJECT#: 60007-039 <br /> m EQUIPMENT RACKS CT <br /> M j-y ISSUE DATE', 10.2.2023 <br /> A 2 <br /> LUG AS REQUIRED o EV J �c7 c m DESIGN MANAGER: GRAPHITE <br /> fl7R CABLE TRAY a d✓ g z z PRODUCTION DESIGNER: GRAPHITE <br /> 0 0 EXISTING 2 SETS OF S- O q <br /> p 0 4-250 KCMIL m T m CHECKED BY: <br /> o WITH GROUND m O m <br /> s 0 0 N 2 ACH 1/2T CONDUIT = Revision Schedule <br /> 0 V AWG EOUIPM£NT Date By I Description <br /> 0 GROUNDING CONDUCXIR TO <br /> 0•'�0 MAIN BUILDING GROUNDING 3/18/2024 REV 1:HVAC REDESIGN <br /> ELECTRODE 1117111 PANEL PANEL LEGEND <br /> EXISTING EXISTING EXISTING <br /> FTL <br /> —NEW WORK <br /> A..FiPAL T ALL ARTS AA81'F 7RT THIS RS ARE <br /> NEW TO£XIS77NG CONNECT? SHEETTITLE: <br /> A. A77T ALL PARTS AAB PART AN,A�E'RS ARE ShO#N'=IN 7IA DETAIL BE ELECTRICAL PANEL SCHEDULES AND <br /> CONTRACTOR ISM-LAAE IS RESPONSIBLE S R A CONPL£TT NOT SAC INSTALLATION, IhC'L(A)ING <br /> MISCFLLAA£OUS APPlAt7EAMA6'ES REIX/IRED BUT NOT s/awrv. ONE-LINE DIAGRAM <br /> R GROUND BAR DETAIL 1 - ONLY SCALE:AS SHOWN <br /> NOT TO SCALE NOT TO SCALE <br /> EXISTING ONE-LINE DIAGRAM SHOWN FOR REFERENCE <br /> 2 CAI SHEETNUMBER: <br /> o `J .1L11 <br /> "�""�' E601 <br />