My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1010 N BROADWAY 2023 STARBUCKS Plans 2025-06-30
>
Address Records
>
N BROADWAY
>
1010
>
STARBUCKS
>
Plans
>
1010 N BROADWAY 2023 STARBUCKS Plans 2025-06-30
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2025 1:12:03 PM
Creation date
5/7/2025 8:18:57 AM
Metadata
Fields
Template:
Address Document
Street Name
N BROADWAY
Street Number
1010
Tenant Name
STARBUCKS
Permit
B2311-026
Year
2023
Notes
TI EXISTING STARBUCKS CAFE, PARTITIONS, EQUIPT RELOCATION
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
60
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EXISTING PANEL "B" EXISTING PANEL "A" <br /> FED FROM: PANEL"A" MOUNTING: FLUSH MOUNTED FED FROM: UTILITY TRANSFORMER MOUNTING: FLUSH MOUNTED <br /> VOLTAGE: 208Y/12OV.3 PHASE,4 WIRE ENCLOSURE: NEMA 1 VOLTAGE: 20BY/12OV, 3 PHASE,4 WIRE ENCLOSURE: NEMA 1 = <br /> BUS MATERIAL: EXISTING FAULT CURRENT: EXISTING BUS MATERIAL: EXISTING FAULT CURRENT: EXISTING <br /> BUS LOAD: 137 AMPS AIC/SCCR RATNG: MATCH EXISTING BUS LOAD: 353 AMPS AIC/SCCR RATING: MATCH EXISTING <br /> : <br /> BUS RATING: 4GO AMPS OPTIONS*: BONDED EQUIPMENT GROUND BAR BUS RATING: 400 AMPS OPTIONS*: BONDED EQUIPMENT GROUND BAR <br /> MAINMAIN LUG ONLY MAIN: 400/3 MAIN BREAKER <br /> LOAD(VA) LOAD(VA) LOAD(VA) LOAD(VA) <br /> NOTES CKT. LOAD DESCRIPTION A B C BREAKER BREAKER A B C LOAD DESCRIPTION CKT. NOTES NOTES CKT. LOAD DESCRIPTION I A B C IBREAKERIBREAKER A I B C I LOAD DESCRIPTION CKT. NOTES <br /> C-1 1 WORKROOAI/BAR UGHTS 1643 20/1 20/1 300 EXTERIOR SIGNS 2 C-3 1 RTU-1 7176 70/3 20/2 1144 ICE MAKER,HEAD 2 GFCI <br /> C-2 3 CAFE UCHTS 250 20/1 20/1 200 MENU BOARD 4 C-3 3 ----- 7176 --- --- 1144 4 ©zazz sTnRsucKs-FEE COMPANY <br /> ____ <br /> 5 20/1 200 DT SIGNS 5 C-3 5 ----- 7176 1 --- 20/1 460 UC REFRIGE. 6 GFCI <br /> 7 ASHP-1 2212 40/2 40/3 2333 WATER HEALER 8 7 --2 7176 70/3 20/1 1500 INSTAHOT 8 GFCI �`T /V /C"'� <br /> 9 --- 221 --- --- 10 9 ----- 7176 --- 20/1 460 UC REFRIGE. 10 GFCI S /-1 LJ K J <br /> HPL 11 --- 2333 ---- 12 11 ----- 7176 --- 20/1 1500 INSTAHOT 12 GFCI 2835 N MCCARRAN BLVD#103 <br /> --- 20/1 Ih!II ^""1:^u!!9ULLOING LIGHTS'. 14 C-3 GFCI 13 WATER FILLING STATION 1300 20/1 20/1 540 SEATING RECEPTS. 14 SPARKS,NEVADA 89431 <br /> GFCI 15 DIGITAL MENU BOARD 360 20/1 20/ 708 AHU-1 6 GFCI 15 WATER FLUNG STATION 180 20/1 20/1 SPARE 16 (775)331-8551 <br /> GFCI 17 REACH-IN REFRIG. 1000 20/1 ---„ 708 ----- iB GFCI 17 ESPRESSO 2975 40/2 20/1 100 RAIN BIRD 18 <br /> GFCI 19 REACH-IN REFRIG. 1000 20/1 20/2•"' '400 - -;'' 2C C-4 19 ----- 2975 --- 20/1 100 SPEAKER POST 20 THESE DRAWINGS AND THE PROJECT MANUAL <br /> GFCI 21 MANAGER'_DESK 720 20/1 --- 400 ----- 22 GFCI 21 ESPRESSO 2975 40/2 20/1 1500 RR HAND DRYER 22 HPL ARE CONFIDENTIAL AND SHALL REMAIN THE <br /> GFCI 23 MANAGER'S DESK 960 20/1 20/1 100 LIGHTING CONTROL PANEL 24 23 ----- 2975 --- 20 1 900 IT RACK 24 GFCI SOLE PROPERTY OF STARBUCKS <br /> / CORPORATION,WHICH IS THE OWNER OF THE <br /> GFCI 25 MILK/ICE DISPENSER 1800 20/1 20/1 1000 REACH-IN REFRIGE. 26 GFCI 25 ROOF RECEPT. 360 20/1 15/1 568 REDRC.PUMP,P-1 26 C-1 COPYRIGHT IN THIS WORK.THEY SHALL NOT <br /> GFCI 27 GRINDER 1800 20/1 20/1 1000 REACH-IN REFRIGE. 28 27 DUCT SMOKE DETECTOR 100 20/1 20/1 180 ICE MAKER,DIMORTER 28 GFCI BE REPRODUCED(IN WHOLE OR IN PART), <br /> GFCI 29 UC REFRIGE. 460 20/1 20/1 90 RR AND VESTIB.EM UGHTS 30 FCl/C-1 GFCI 29 PARTNER AREA MICROWAVE 1200 20/1 20/1 460 UC REFRIGE 30 GFCI SNARED WITH THIRD PARTIES OR USED IN ANY <br /> MANNER ON OTHER PROJECTS OR <br /> GFCI 31 OVEN 3000 30/2 20/1 720 DT POS 32 GFCI GFCI 31 DT WINDOW 300 2, 20/1 SPARE 32 EXTENSIONS TO THIS PROJECT WITHOUT THE <br /> 33 ----- 3000 --- 20/1 SPARE 34 GFCI GFCI 33 NITRO DISPENSER 12DO 20/1 30/2 2984 WARMING WALL 34 GFCI PRIOR WRITTEN CONSENTOF STARBUCKS <br /> GFq 35 OVEN 3000 30/2 201/1 720 DT POE 36 GFCI GFCI 35 NITRO GENERATOR 720 20/1 2984 36 CORPORATION.THESE DRAWINGS AND <br /> 37 ----- 3000 --- 20/1 640 DT UC REFRIGE. 38 GFCI GFCI 37 REACH-IN FREUER 660 20/1 30/3 2831 COM I-OVEN 38 GFq SPECIFICATIONS ARE INTENDED TO EXPRESS <br /> HPL 39 SANrnzER 3120 40/2 50/2 4160 BREWER 40 GFCI GFCI 39 POS 540 20/1 --- 2831 __—_ 40 DESIGN INTENT FOR A PROTOTYPICAL <br /> STARBUCKS STORE(WHICH IS SUBJECT TO <br /> SPARE 20/1 --- 2831 ---- 42 CHANGE AT ANYTIME)AND DO NOT REFLECT <br /> FEED-THROUGH LUGS ACTUAL SITE CONDITIONS,NEITHER PARTY <br /> NOTES: 16342 FTL SUBFEED PANEL E' SHALL HAVE ANY OBLIGATION NOR LIABILITY TO <br /> * SEE SPECIFICATIONS FOR OTHER OPTIONS REQUIRED BUT NOT NECESSARILY NOTED HERE 16267 FTL -___ THE OTHER(EXCEPT STATED ABOVE)UNTIL <br /> GFCI PROVIDE GROUND-FAULT CIRCUIT-INTERRUPTER(GFCI)5 MILLIAMP TRIP TYPE CIRCUIT BREAKER. WRITTEN AGREEMENT IS FULLY EXECUTED BY <br /> HPL PROVIDE PERMANENTLY-INSTALLED HANDLE PADLOCK ACCESSORY TO LOCK CIRCUIT BREAKER IN THE OPEN POSITION. 13704 FTL I BOTH PARTIES, <br /> C-# ROUTE CIRCUIT THROUGH CONTACTOR( =CONTACTOR DESIGNATION). <br /> NOTES: STARBUCKS TEMPLATE VERSION:12023.04.24 <br /> SEE SPECIFICATIONS FOR OTHER OPTIONS REQUIRED BUT NOT NECESSARILY NOTED HERE <br /> LOAD ANALYSIS FOR PANEL "B INCLUDING SUBFEEDS GFCI PROVIDE GROUND—FAULT CIRCUIT—INTERRUPTER(GFCI)5 MILLIAMP TRIP TYPE CIRCUIT BREAKER. <br /> ( ) HPL PROVIDE PERMANENTLY—INSTALLED HANDLE PADLOCK ACCESSORY TO LOCK CIRCUIT BREAKER IN THE OPEN POSITION. ARCHITECT OF RECORD <br /> DEMAND PHASE A(VA) PHASE B(VA) PHASE C(VA) TOTAL(VA) C_# ROUTE CIRCUIT THROUGH CONTACTOR(#=CONTACTOR DESIGNATION). <br /> LOAD DESCRIPTION FACTOR CONNECT.I DEMAND CONNECTI DEMAND CONNECT. DEMAND ICONNECT. DEMAND <br /> LIGHTING: 125% 2543 3179 850 1063 290 363 3683 4604 uw.ruxu .,,ss,,..,s�..,.,A•�u«...e_�„:nx�.,o <br /> RECEPTACLE: 100% 1360 1360 1080 1080 1680 1680 4120 4120 LOAD ANALYSIS FOR PANEL "A" (INCLUDING SUBFEEDS) <br /> OTHER NONCONTINUOUS: 100% 0 0 0 0 100 100 100 100 DEMAND PHASE A(VA) PHASE B(VA) I PHASE C(VA) I TOTAL(VA) GRAPHITE DESIGN GROUP,LLC,ARCHITECTS <br /> WATER HEATING: 100% 2334 2334 2334 2334 2334 2334 7000 7000 LOAD DESCRIPTION FACTOR CONNECT. DEMAND CONNECT. DEMAND CONNECT. GRAPH <br /> DEMAND CONNECT. DEMAND 1807 GRAPHH AVENUE,SUITE 700 <br /> KITCHEN: 65% 10600 6890 13080 8502 12540 8151 36220 23543 LIGHTING: 125% 2543 3179 850 1063 290 1 363 3683 4604 SEATTLE,WA 9B101 <br /> MOTOR: 700% 2212 2212 2920 2920 708 708 5840 5840 RECEPTACLE: 100% 2260 2260 2440 2440 4700 4700 9400 9400 (206)224-3335 <br /> ADD 25%OF LARGEST MOTOR: 100% 369 369 369 369 369 369 1106 1106 OTHER NONCONTINUOUS: 100% 400 400 160C 1600 200 200 2200 2200 <br /> TOTAL 19417 16343 20632 16267 18020 13704 58069 46313 WATER HEATIN2: 100% 2334 2334 2334 2334 2334 2334 7000 7000 <br /> EQUIVALENT AMPS: 162 137 172 136 151 115 162 129 KITCHEN: 65% 21010 13657 24214 15740 26525 17242 71749 46637 <br /> PHASE BALANCE: 5.86% 5.37R -11.23% COOLING ONLY: 100% 14352 14352 14352 14352 14352 14352 43056 43056 O�y �OHNyn <br /> MOTOR: 100% 2780 2780 2920 2920 705 708 6408 6408 ti <br /> ADD 25%OF LARGEST MOTOR: 100% 1 1794 1794 1 1794 1794 1794 1794 5382 5382 y g m <br /> TOTAL: 47472 1 40754 1 50504 42241 50903 41692 148878 124686 <br /> EQUIVALENT AMPS: 396 340 421 353 425 348 414 3471 31 <br /> PHASE BALANCE: -1.94% 1.639. 0.31% of E1+E <br /> ONAL Dora 1012512J <br /> CO {2509 <br /> F- < N <br /> C) j 00 <br /> PAD MOUNT TRANSFORMER 06 >� <br /> BY LOCAL UTILITY COMPANY O <br /> TRANSFORMER PAD Q V) <br /> BY ELECTRICAL <br /> CONTRACTOR LLlLU <br /> PRIMARY CONDUIT <br /> BY ELECTRICAL Z Q Z <br /> CONTRACTOR O <br /> U O L) <br /> N D LU <br /> PRIMARY FEEDERS BY EXISTING 2 SETS OF c i m I \ <br /> LOCAL UTILITY COMPANY 4-250 KCMIL <br /> WITH GROUND A C)O m MM O <br /> EACH SET z ai E m d W d r W <br /> �pzrc <br /> 114'x 4"x 12"COPPER GROUND 0 IN 2 1/2'CONDUIT Z o p; STORE#: 22817 <br /> BAR H7TH WALL MOUN77NG r m x <br /> BRACKE75 AND/NSULA TORS —T m m <br /> LUG AS REQUIRED FOR mn m N PROJECT#: 60007-039 <br /> m EQUIPMENT RACKS CT <br /> M j-y ISSUE DATE', 10.2.2023 <br /> A 2 <br /> LUG AS REQUIRED o EV J �c7 c m DESIGN MANAGER: GRAPHITE <br /> fl7R CABLE TRAY a d✓ g z z PRODUCTION DESIGNER: GRAPHITE <br /> 0 0 EXISTING 2 SETS OF S- O q <br /> p 0 4-250 KCMIL m T m CHECKED BY: <br /> o WITH GROUND m O m <br /> s 0 0 N 2 ACH 1/2T CONDUIT = Revision Schedule <br /> 0 V AWG EOUIPM£NT Date By I Description <br /> 0 GROUNDING CONDUCXIR TO <br /> 0•'�0 MAIN BUILDING GROUNDING 3/18/2024 REV 1:HVAC REDESIGN <br /> ELECTRODE 1117111 PANEL PANEL LEGEND <br /> EXISTING EXISTING EXISTING <br /> FTL <br /> —NEW WORK <br /> A..FiPAL T ALL ARTS AA81'F 7RT THIS RS ARE <br /> NEW TO£XIS77NG CONNECT? SHEETTITLE: <br /> A. A77T ALL PARTS AAB PART AN,A�E'RS ARE ShO#N'=IN 7IA DETAIL BE ELECTRICAL PANEL SCHEDULES AND <br /> CONTRACTOR ISM-LAAE IS RESPONSIBLE S R A CONPL£TT NOT SAC INSTALLATION, IhC'L(A)ING <br /> MISCFLLAA£OUS APPlAt7EAMA6'ES REIX/IRED BUT NOT s/awrv. ONE-LINE DIAGRAM <br /> R GROUND BAR DETAIL 1 - ONLY SCALE:AS SHOWN <br /> NOT TO SCALE NOT TO SCALE <br /> EXISTING ONE-LINE DIAGRAM SHOWN FOR REFERENCE <br /> 2 CAI SHEETNUMBER: <br /> o `J .1L11 <br /> "�""�' E601 <br />
The URL can be used to link to this page
Your browser does not support the video tag.