Laserfiche WebLink
INTERIOR WALL SCHEDULE WALL BLOCKING KEY WALL SHEATHING KEY KEYED NOTES GENERAL NOTES <br /> TAG DESCRIPTION INSULATION NOTES SYMBOL ITEM WEIGHT HEIGHT A.F.F. APPROX.WIDTH SYMBOL DESCRIPTION <br /> GENERIC TYPE 1-2 1/8"FURRING WORKROOM 126 LBS 36"TO 40" INDICATES SHEATHING <br /> 1. ALIGN FACE OF FINISHED WALL. A. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS <br /> A (58 KG) (915MM TO 1015MM) 30"(760MM)BEHIND SINK TRANSITION AND NOTIFY STARBUCKS CONSTRUCTION MANAGER OF <br /> WALL HAND SINK 2. ELECTRICAL PANEL LOCATIONS.MAINTAIN MINIMUM ANY DISCREPANCIES PRIOR TO CONSTRUCTION.ALL <br /> 2-F-N 3 STUD FURRING WALL NONE FULL HT.WALL.SEE PLAN FOR WALL SHEATHING. SHELVES ABOVE 200 LBS 48"TO 76" 98"(2440MM)CENTERED ABOVE 5/8"GYP.WALL BOARD CLEARANCE AS REQUIRED BY CODE. DIMENSIONS TO BE TAKEN FROM DESIGNATED DATUM <br /> 3 GENERIC <br /> C T T YPE 3-4 7/8"WALL O COMPARTMENT SINK (91 KG) (1220MM TO 1930MM) COMPARTMENT SINK O (FULL WALL HEIGHT) POINT. <br /> 3-F-N 3 5/8"20 GA STUDS @ 18"O.C. NONE FULL HT.WALL.SEE PLAN FOR WALL SHEATHING. UPPER 5/8"GYP.WALL BOARD 3. FUR OUT INTERIOR FACE OF WALL. <br /> 3-T-A 3 5/8"20 GA STUDS @ 16"O.C. ACOUSTIC TERMINATE 6"ABOVE CEILING.PROVIDE 45 DEGREE O WIRE SHELVES BLOCKING SPECIFICATION TO BE PROVIDED BY VENDOR O (TERMINATE AT 6"(150MM) B. GENERAL CONTRACTOR TO PROVIDE FIRE TREATED <br /> METAL STUD BRACING AT 48"O.C.FROM STUD WALL TO SHELVES AT 300 LBS 32"TO 96" 48"(1220MM)3/4(19MM ACX ABOVE CEILING) WOOD STUD BLOCKING,OR EQUIVALENT TO SUPPORT <br /> STRUCTURE ABOVE.SEE PLAN FOR WALL SHEATHING. O ) ANY WALL ATTACHMENTAND/OR SIGNAGE. a <br /> 3-T-N 3 5/8"20 GA STUDS @ 16"O.C. NONE TERMINATE 6"ABOVE CEILING.PROVIDE 45 DEGREE MANAGER'S DESK (136 KG) (810MM TO 2440MM) PLYWOOD,CENTERED ON SIB"CEMENTIVE CEILING) <br /> BACKER <br /> METAL STUD BRACING AT 48"O.C.FROM STUD WALL TO SHELVES O BOARD(TERMINATE AT 6" C. IF EXISTING EXTERIOR ENTRANCE THRESHOLD ©m 2Sr UCKS COFFEE COMFAW <br /> EQUIPMENT RACK AT 300 LBS 44"TO 96" 28"71 GMM 314 19MM ACX (150MM)ABOVE CEILING) <br /> STRUCTURE ABOVE.SEE PLAN FOR WALL SHEATHING. E ( ) ( ) EXCEEDS MINIMUM BARRIER FREE PROVISION OF THE <br /> MANAGER'S DESK (136 KG) (1120MM TO 2440MM) PLYWOOD,CENTERED ON RACK 5/B"CEMENTITIOUS BACKER CODE,REMOVE AND REPLACE WITH ACCESSIBLE STARBUCKS <br /> 4T-A 8"20 GA STUDS 16"O.C. ACOUSTIC TERMINATE 8"ABOVE CEILING.PROVIDE T DEGREE <br /> METAL STUD BRACING AT 48"O.C.FROM STUD WALL TO METRO BLOCKING SPECIFICATION TO BE PROVIDED BY VENDOR.IN- BOARD(TERMINATE AT FINISH THRESHOLD.RAISED THRESHOLDS AND FLOOR LEVEL <br /> STRUCTURE ABOVE.SEE PLAN FOR WALL SHEATHING. OF SHELVES WALL BLOCKING PREFERRED,HOWEVER EXISTING FRP FINISHED O TRANSITION AS SHOWN ON CHANGES AT ACCESSIBLE DOORWAYS TO BE BEVELED 2401 UTAH AVENUE SOUTH <br /> WALL MAY RECEIVE SURFACE MOUNTED,PAINTED WHITE. INTERIOR ELEVATION W/5/8" WITH A SLOPE NO GREATER THAN 1:12. <br /> ORESTROOM 200 LBS 30"TO 36" 80"(1525MM)AROUND WATER GYP.WALL BOARD ABOVE SEATTLE,WASHINGTON 98134 <br /> GRAB BARS (91 KG) (760MM TO 915MM) CLOSET (FULL WALL HEIGHT)). D. ALL DIMENSIONS ARE TO FINISHED FACE UNLESS (206)318-1575 <br /> REST5I8"PLYWOOD SHOWN OR NOTED OTHERWISE. <br /> HAND SINK (91 LBS COMMERCIAL INSTALLATION REQUIRES CONCEALED <br /> H HAND SINK (TERMINATE AT 6"(150MM) E., INSTALL MOISTURE RESISTANT GREEN BOARD ON THESE DRAWINGS AND THE PROJECT MANUAL <br /> (91 KG) ARM CARRIER.REFER TO MFR'S SPECIFICATION. ABOVE CEILING) ARE CONFIDENTIAL AND SHALL REMAIN THE <br /> BACKBAR WALL PER PROJECT MANUAL. SOLE PROPERTY OF STARBUCKS <br /> O MILLWORK BLOCKING SPECIFICATION FOR FRENCH CLEATING SYSTEM. O 5/8"GYP.WALL BOARD CORPORATION,WHICH IS THE OWNER OF THE <br /> BOXES REFER TO DETAILS. (FULL WALL HEIGHT) F. ALL DOORS SHALL BE 32'(815MM)MINIMUM CLEAR COPYRIGHT IN THIS WORK.THEY SHALL NOT <br /> DIAPER CHANGING 250 LBS 1401/2"TO 46 1/2" 32"(810MM)BEHIND STATION OPENING WHEN OPENED TO 90 DEGREE POSITION <br /> J BE REPRODUCED(IN WHOLE OR IN PART), <br /> STATION (113 KG) (1030MM TO 1180MM) UNLESS OTHERWISE NOTED. SHARED WITH THIRD PARTIES OR USED IN ANY <br /> OUPPER CBE BLOCKING SPECIFICATION FOR CBE METAL SHELVES. MANNER ON OTHER PROJECTS OR <br /> SHELVING REFER TO VENDOR'S SPECIFICATION AND DETAILS. G. SEE SHEET A601 FOR EXTERIOR DOOR AND WINDOW EXTENSIONS TO THIS PROJECT WITHOUT THE <br /> WATER FILTRATION TBD BY SCHEDULES. PRIOR WRITTEN CONSENT OF STARBUCKS <br /> OL CORPORATION.THESE DRAWINGS AND SYSTEM COORDINATE LOCATION AND EXTENT WITH PENTAIR H. STARBUCKS VENDOR TO PROVIDE DOOR HARDWARE SPECIFICATIONS ARE INTENDED TO EXPRESS <br /> VENDOR <br /> ALL ARTWORK, COMPONENTS AND GC TO INSTALL. DESIGN INTENT FOR A PROTOTYPICAL <br /> FIXTURES, TBD BY GC TO PROVIDE WALL BLOCKING AS REQUIRED FOR STARBUCKS STORE(WHICH 15 SUBJECT TO <br /> ACCESSORIES AND VENDOR ALL ITEMS FOR A COMPLETE AND SECURE I. VERIFY ALL EXISTING DOORS,HARDWARE AND FRAMES CHANGE AT ANYTIME)AND DO NOT REFLECT <br /> CASEWORK INSTALLATION. EXTEND BLOCKING 8"(205MM) MEET STARBUCKS AND/OR CODE REQUIREMENTS. <br /> FABRICATIONS NOT (VARIES) BEYOND ON EACH SIDE OF EACH ITEM. ACTUAL SITE CONDITIONS.NEITHER PARK <br /> OTHERWISE NOTED J. PROVIDE FIRE EXTINGUISHERS AS NOTED ON THE SHALL HAVE ANY OBLIGATION NOR LIABILITY TO <br /> THE OTHER(EXCEPT STATED ABOVE)UNTIL A <br /> APPROVED PLANS FROM THE CITY, WRITTEN AGREEMENT IS FULLY EXECUTED BY <br /> K. SEE STRUCTURAL FOR KNEE WALL BRACING. <br /> BOTH PARTIES. <br /> L. SEE SHEET A501 FOR BUILDING DETAILS. STARBUCKS TEMPLATE VERSION:i2021.10.22 <br /> M. REFER TO SHEET 1104 FOR FLOOR FINISHES. ARCHITECT OF RECORD <br /> !a GRAPHITE <br /> GENERAL LEGEND GRAPHITE DESIGN GROUP,LLC,ARCHITECTS <br /> 1807 7TH AVENUE,SUITE 700 <br /> SEATTLE,WA 98101 <br /> NEW FULL HEIGHT WALL (206)224-3335 <br /> 0 EXISTING WALL <br /> 4'-2" T-2" 2'-4" 51YP' 5'-101/4" 4'-31/2" 3'-0" 6'-81/4" <br /> VIF @> WALL SHEATHING CALL-OUT 9335 REGIS D <br /> 5'-6 114" DATUM POINT <br /> VIF MARTIN LEE HILL <br /> 7 7 STATE OF WASHINGTON <br /> 7 1503 1503 WALL BLOCKING CALL-OUT <br /> 1503 <br /> — — — — SOFFIT ABOVE FOR REFERENCE <br /> 0 <br /> —————--———— <br /> -—— OUTLINE OF CASEWORK FOR REFERENCE <br /> D 10190 04 A A B E D ----- <br /> 1 O 3 a <br /> � I <br /> 3 2-F-N 2-F-N 3-T- 4T-A <br /> O I <br /> B C r B n <br /> L-------------- <br /> — O C 8i 3-T-A N B O <br /> o O B 1 O Og p p ,eft } 0 <br /> 1 3-T-A p °' vV C14 <br /> v 3-T-A <br /> 3-F-N 1 1 3-F-N <br /> ----- --------------------------------------I Q y Q >a <br /> -_ C O O C C `a LLI � K O J <br /> C B <br /> Q O C I C v Z 12 <br /> '-51/2" 4'-0" <br /> --- ------------------J_ --_ _ - --J----- <br /> N 3FN _ WO Wow <br /> 5 0 0 <br /> D 10086 O6 <br /> � " a <br /> w g -—-a -----------_�- - - +——_— __—— - —_--3T�- STORE#: 22817 <br /> 3 i� 3-T•N I I 3 3 3-T-N y LL "O PROJECT#: 60007-039 C O C C C 5 ISSUE DATE: 10/27/2023 <br /> 141' V <br /> I I DESIGN MANAGER: GRAPHITE <br /> --------- 1 I I PRODUCTION DESIGNER:GRAPHITE <br /> I I <br /> 1 CHECKED BY: GRAPHITE <br /> I I <br /> I I 8'-9112" T-81/4" <br /> Revision Schedule <br /> I I <br /> 16'-101/4" 8'-7314" 14'-61/2" I I Rev Dale By Description <br /> VIF I I <br /> 3 <br /> 1503 <br /> SHEET TITLE: <br /> I (FLOOR PLAN BUILDING FLOOR PLAN <br /> - - <br /> N SCALE:AS SHOWN <br /> SHEET NUMBER: <br /> A101 <br />