Laserfiche WebLink
_ Page 1 of 1 <br /> t 1y+�7 <br /> �. ■�1GlL &Associates, lnc. Field <br /> Geotechnical Engineering.Environmental Engineering Report NO.:09623260DFRI 10223DK <br /> Construction Testing and Inspection <br /> DATE: 11/2/2023 Set Count: CONTRACTOR: Donavan <br /> PROJECT#: 09623260 PERMIT#: <br /> PROJECT: Greenwood Heating INSPECTOR: Don Keller <br /> LOCATION: 10930 Airport Rd. JURISDICTION: Everett <br /> KA P.M.: WEATHER: TEMP: <br /> Verified mix#1240AF 4000 psi concrete provided by Miles.Observed the placement of(44.0)cubic yards of concrete for <br /> Detention Pond c.i.p.walls.All loads placed continuously,within 90 minutes of batch time,and with no interruptions greater <br /> than 1 hour.Concrete discharged into hopper,conveyed with boom pump,and mechanically consolidated at time of <br /> placement.Note:Performed additional reinforcing steel pacement inspection.Items noted on inspection report <br /> 09623260DFR102623DK were brought into compliance prior to concrete placement. <br /> Cast 1 set of 5 4x8 concrete specimens @10:30,mix 72,air 50,slump 5". <br /> e it <br /> _. ._ <br /> Reviewed By: ASTM Test#: Asset Numbe s : <br /> To the best o my knowledge,the above WAS performed in accordance with the approved plans,specifications and <br /> regulatory requirements. <br /> Superintendent/Representative: Technician: <br /> Offices Serving the Western United States <br /> Lynnwood(425)485-5519•Poulsbo(360)598-2126•Tacoma(253)939-2500 <br /> The information provided on this report is prepared for the seclusive use of the client.This report may not be reproduced in any format without the written permission of the client and Krazan&Associates.This report <br /> indicates our inspectors observation and testing results based on site conditions and contractor activities.This information is subject to review prior to final submittal.By signing this report,our inspector does not accept <br /> responsibility for validity of results.The same information has been provided by others on site.The test results apply only to the specific locations,and items inspected or tested.Template date 10/4/2023 <br />