Laserfiche WebLink
5FA Design Group, u r <br />STRUCTURAL I CIVIL I LAND USE PLANNING <br />PROJECT <br />Gale Residence UnderDinnina <br />SUBJECT <br />SafeBase-LD (Liaht D <br />Capacity of 3/4"0 GRB7 (125ksi) Threaded Rod <br />71=11 <br />D = 0.750 in <br />Ft = 125 ksi <br />At = 0.344 in' <br />Capacity = 42.950 kips <br />Block Shear at 1/4" Plate m <br />Tss = 0.3(58)(1/4)(4.625)+0.5(58)(1/4)(1)� <br />= 27.369 kips <br />Capacitv of Weld Q <br />E70 Electrodes = 70 ksi <br />Size of Fillet = 0.188 in <br />Length of Weld = 6.000 in <br />Capacity of Per Inch of Fillet = 2.784 kli <br />Capacity of Fillet = 16.705 kips <br />Capacity of/s' Plate <br />At = 1.125 in <br />Ft = 21.600 ksi <br />T = 24.300 kips <br />I = 0.844 in <br />A = 1.125 in <br />r = 0.866 in <br />k = 1.00 <br />I = 7.387 in <br />kl/r = 9.0 <br />Fa = 20.350 ksi <br />S = 3.410 in3 <br />Fb = 27.000 ksi <br />RMAx = 30.857 kips <br />Fv = 14.400 ksi <br />NO. ISHEET NO. <br />DATE <br />2/24/2023 <br />BY <br />CAF <br />t oy2.. <br />r � <br />VALLOW = 10.800 kips t Limiting System Factor <br />Results <br />Capacity of System (2 Sides)=10.800(2)=21.600kips (Bracket Only) <br />H <br />u <br />