Laserfiche WebLink
5FA Design Group, LL.0 PROJECT NO. SHEET NO. <br />STRUCTURAL I GEOTECHNICAL I SPECIAL INSPECTIONS MFR22-280 <br />Residence Underpinni <br />Loads <br />Distributed Load Along (E) Beam Gridline A.5 (For Load Generation Only) <br />Load Type <br />Design Load <br />Tributary Length <br />Line Load <br />RoofDL _ <br />(15 psf) <br />(4.00 ft) <br />= 60 plf <br />Dead Load 0.522 kips <br />RoofSL = <br />(25 psf) <br />(4.00 ft) <br />= 100 plf <br />Floor Live Load 0.560 kips <br />2ndFloorDL _ <br />(15 psf) <br />(2.00 ft) <br />= 30 plf <br />Roof Snow Load 0.100 kips <br />2ndFloon_L _ <br />(40 psf) <br />(2.00 ft) <br />= 80 plf <br />Controlling ASD Load Combination: <br />1stFloorDL _ <br />(15 psf) <br />(12.00 ft) <br />= 180 plf <br />D+L <br />1 stFloon_L _ <br />(40 psf) <br />(12.00 ft) <br />= 480 plf <br />lnteriorWallDL _ <br />(9 psf) <br />(16.00 ft) <br />= 144 plf <br />ExteriorWallDL _ <br />(12 psf) <br />(9.00 ft) <br />= 108 plf <br />Distributed Load Along (E) Beam For Load Generation Only) 1.082 kips <br />